Atlas MLGC240W manual Installation, Wall Mount, Mount the Light Control, Wire the Light Control

Page 2

INSTALLATION

For easy installation, select an existing light with a wall switch for replacement.

Wall Mount

Eave Mount

Mounting

Strap

Black to Black

White to White

Rubber

Plug

Mounting

Bolt

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk23456789012345678of electrical shock.

For eave mount only:

Swing the sensor head towards the clamp screw joint.

Controls

Clamp Screw

Then rotate the sensor head clockwise 180° so the controls face down.

Controls

Controls

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

Gasket

Junction box ground wire to green ground screw on fixture.

MOUNT THE LIGHT CONTROL.

Align the Light Control cover plate and cover plate gasket. Secure with the mounting bolt.

Align the three slots in the decorative shell with the lamp holder pins. Push the shell in and then twist clockwise to lock. Repeat for other shell.

Shell Slot

Push the Rubber Plug firmly into place.

If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant.

To avoid water damage and electrical shock, keep lamp holders 30° below horizontal.

WIRE THE LIGHT CONTROL.

Turn power off at the fuse or circuit breaker.

Remove the existing light fixture.

Install the mounting strap as shown using two screws that fit your junction box.

The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.

Route the Light Control’s wires through the large gasket holes.

Twist the junction box wires and fixture wires together as shown. Secure with wire connectors.

 

Keep lamps at least

 

1" (2.5 cm) from the

Lock Nut

sensor. Do not al-

Lens

low the lamps to

block the lens.

Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting. When screwing in the floodlamps, do not overtighten.

-2-

598-1094-01

Image 2
Contents Operation FeaturesMode Switching Summary RequirementsWall Mount InstallationWire the Light Control Mount the Light ControlTurn on the circuit breaker and light switch Test and AdjustmentSpecifications Avoid aiming the control atTroubleshooting Guide Symptom Possible Cause

MLGC240B, MLGC240W specifications

The Atlas MLGC240W and MLGC240B are cutting-edge devices designed for high-performance applications in various industrial and commercial environments. These models exemplify the latest advancements in technology and engineering, ensuring reliability, efficiency, and adaptability.

One of the standout features of the Atlas MLGC240 series is its robust processing power. With an advanced multi-core processor, these models can handle demanding workloads and complex tasks with ease. This makes them ideal for applications requiring real-time data processing, such as machine learning, artificial intelligence, and large-scale data analytics.

The MLGC240W and MLGC240B also boast impressive connectivity options. They support various communication protocols, including Ethernet, Wi-Fi, and Bluetooth, allowing seamless integration into existing networks. This flexibility enables users to connect and communicate with other devices effortlessly, making the Atlas series suitable for IoT applications and smart environments.

In terms of storage, both models feature expansive memory options that cater to extensive data usage. The MLGC240 series is equipped with high-speed SSD storage, providing rapid data access and retrieval. This speed is crucial for applications that require instant responsiveness and minimal downtime, ensuring continuous operation even under heavy workloads.

The design of the Atlas MLGC240W and MLGC240B prioritizes durability and longevity. With industrial-grade components, these devices are built to withstand harsh conditions, including extreme temperatures and humidity levels. This resilience makes them ideal for deployment in demanding environments, such as manufacturing plants, warehouses, and other industrial settings.

User-friendly software is another core component of the Atlas MLGC240 series. Featuring an intuitive interface, these models allow operators to manage and monitor their performance effortlessly. Additionally, comprehensive analytics software provides insightful data visualizations and reporting tools, empowering users to make informed decisions based on real-time insights.

Security is a key focus with the Atlas MLGC240 models. They come equipped with advanced encryption technologies and secure boot features to protect sensitive data from unauthorized access. This commitment to security ensures that users can rely on these devices for secure data management and processing.

In summary, the Atlas MLGC240W and MLGC240B stand out for their powerful processing capabilities, versatile connectivity, ample storage, robust design, user-friendly software, and stringent security measures. Together, these features make the Atlas MLGC240 series an excellent choice for businesses seeking reliable technology solutions that can adapt to their evolving needs.