Broan HRV90HS Installation CONT’D, Make sure the unit is level, Stale air exhaust ductwork

Page 10

3. INSTALLATION (CONT’D)

3.4HOW TO HANG THE UNIT

Hang the unit with the 4 chains, hooks and springs provided.

VD0184

VD0185

CAUTION

Make sure the unit is level.

3.5PLANNING OF THE DUCTWORK

Keep it simple. Plan for a minimum of bends and joints.

Keep the length of insulated ducts to a minimum.

Do not ventilate crawl spaces or cold rooms. Do not attempt to recover the exhaust air from a dryer or a range hood. This would cause clogging of the filters and recovery module.

If the house has two floors or more, be sure to plan for at least one exhaust register on the highest lived-in level.

3.6INSTALLING THE DUCTWORK AND REGISTERS

!WARNING

Never install a stale air exhaust register in a closed room where a combustion device operates, such as a gas furnace, a gas water heater or a fireplace.

3.6.1FULLY DUCTED SYSTEM (AS ILLUSTRATED IN SECTION 2.1)

Stale air exhaust ductwork

Install the stale air exhaust registers where the contaminants are produced: kitchen, living room, etc. Position the registers as far from the stairway as possible and in such a way that the air circulates in all the lived-in spaces in the house.

If a register is installed in the kitchen, it must be located at least 4 feet (1.2 m) from the range.

Install the registers 6 to 12 inches (152 to 305 mm) from the ceiling on an interior wall OR install them in the ceiling.

Fresh air distribution ductwork

Install the fresh air distribution registers in bedrooms, dining rooms, living room and basement.

Keep in mind that the fresh air registers must be located as far as possible from the stale air registers.

Install the registers in the ceiling OR 6 to 12 inches (152 to 305 mm) from the ceiling on an interior wall. The duct lenght should be at least 15’ (4.6 m). (The fresh air will then flow through the room and mix with room air, ensuring a continuous renewed airflow.)

If a register must be floor installed, direct the airflow up the wall.

- 10 -

Image 10
Contents Installation Instructions HRV90H and ERV90HC About this Manual About These Units LimitationTable of Contents Technical Data HRV ERVTechnical Data CONT’D Ventilation PerformanceHRV Typical Installations Typical Installations CONT’D Installation Stale air exhaust ductwork Installation CONT’DMake sure the unit is level Fresh air distribution ductworkDuct, see figure beside Method 1 Supply side connectionMethod 2 Return side connection Stale air intake Method 2B Return-return with Automatic fresh air bypassFresh air distribution Rigid ducts Insulated flexible ductsDo not use screws to connect the rigid ducts to the ports 457 mm Xmas tree pin ’’ Ø Controls AvertissementControls CONT’D No C NC I OC OL Y R G BElectrical Connection to the Furnace OC OL Y R G6WIRINGDIAGRAM Balancing the Unit Connecting the Drain HRV Units only To drainMaintenance Maintenance CONT’D Service Parts HRV90HS HRV90HT ERV90HCS ERV90HCTTroubleshooting Problems Possible causes You should try this

ERV90HC, HRV90HS, HRV90H, ERV90HCS specifications

The Broan HRV90H, ERV90HCS, HRV90HS, and ERV90HC are advanced energy recovery ventilators designed to optimize indoor air quality while efficiently managing energy consumption in residential and commercial spaces. These models exemplify the marriage of function, effectiveness, and technology to ensure that you have a constant supply of fresh air without sacrificing comfort.

One of the main features of these units is their energy recovery technology. The HRV models are designed to recover heat from the outgoing stale air and transfer it to incoming fresh air, while the ERV models go a step further by transferring both heat and moisture. This is especially beneficial in climates where maintaining humidity levels is crucial for comfort. By using these units, homeowners can enjoy fresh air without throwing away energy costs associated with heating or cooling.

The compact design of the Broan HRV and ERV systems allows for flexible installation in various settings. They can be easily integrated into existing HVAC systems or used in new constructions. Each model is equipped with user-friendly controls, featuring various operation modes to suit different needs, whether it's a high-demand situation or a standard ventilation requirement.

Another standout characteristic is their quiet operation. Engineered with sound-dampening materials, these units ensure that they run quietly, allowing you to enjoy a peaceful indoor environment. Additionally, their high-efficiency filters capture airborne particles, thus promoting a healthier living space by reducing allergens and other irritants.

In terms of energy efficiency, the Broan HRV and ERV units boast impressive performance ratings, which can help homeowners save significantly on energy bills over time. The technology used in these products meets industry standards and certifications, ensuring that they not only perform well but also adhere to environmental regulations.

With a commitment to quality and reliability, Broan offers these energy recovery ventilators as a smart choice for those looking to enhance indoor air quality while remaining energy-conscious. The HRV90H, ERV90HCS, HRV90HS, and ERV90HC are the perfect solutions for creating a more comfortable, healthy, and efficient living or working environment. Whether you are renovating an older home or planning a new build, these systems provide an innovative approach to modern ventilation needs.