4.0 INSTALLATION
Before installing the HS2000 to a wall, make certain that the mounting surface is able to support the full weight of the enclosure plus the camera and lens.
The tilt table and tilt table mounting brackets may be removed to provide adequate clearance for mounting the enclosure.
NOTE: The four (4) fasteners required to se- cure the HS2000 to a wall (minimum 3/8" di- ameter recommended) are not supplied.
4.1 CEILING MOUNTING (FLUSH)
To mount the enclosure to a wall (tight to the ceiling), perform the following steps:
1.Remove the cover from the mounting bracket. A special socket is provided (fits 1/4" square drive).
2.Using the mounting bracket or the template pro- vided, mark and drill holes in the mounting sur- face.
3.Attach the enclosure with the required fasteners.
4.Route the required cables through the back or top.
5.Mount the camera/lens to the tilt table.
6.Make all appropriate connections (i.e., camera power, video (coax), lens).
7.Position the camera and tighten the
8.Replace the cover and check that all components clear. Secure with the
NOTE: A plate is provided to prevent access through the top of this enclosure. If needed, it is mounted with the mounting bracket using the same mounting holes and hardware.
4.2 MID-WALL MOUNTING
To mount the HS2000 enclosure
1.Determine the position for the hood. Using it as a template, mark and drill holes in the mounting sur- face.
2.Attach the hood with the required fasteners (mini- mum 3/8" diameter recommended).
3.Continue with steps
4.3 WINDOW INSTALLATION
The HS2000 is provided with a clear Lexan 1/4" thick viewing window. An optional smoked window, HS200010019, is available.
Instructions for installing the optional smoked window are as follows:
1.Remove the cover from the mounting bracket. A special socket is provided.
2.Remove the four (4)
3.Remove the window.
4.Remove the protective coatings from the new win- dow and place the window over the four (4)
5.Replace the hardware and replace the cover.
Pelco Manual | 3 |