Pelco CM9760-MGR user manual Addendum 9/02

Page 3

2.Define which camera groups can be viewed on each monitor by entering the group number(s) in the Group Access field.

To select groups, click the Grp Acc but- ton. The Group Access Table appears. Click the box in front of the group number to toggle the X on or off. An X in the box grants access; no X denies access.

Group Access identifies the camera groups that can be viewed on each monitor.

In this example:

Monitors 1-3 can view cameras that have been assigned to group 1 and any cam- eras that have not been assigned to a spe- cific group (0 in C/M Group field in step 1). These monitors cannot view cameras from any other group; that is, groups 2-32.

Monitors 4-9 can view cameras that have been assigned to groups 1 and 2 and any cameras that have not been assigned to a specific group (0 in C/M Group field in step 1). These monitors cannot view cameras from any other group; that is, groups 3-32.

Monitors 10-13 can view cameras that have not been assigned to a specific group (0 in C/M Group field in step 1). These monitors cannot view cameras from any group; that is, 1-32.

Monitors 14-16 have been given access to all 32 groups. Therefore, they can view any camera that has been assigned to a group (1-32) as well as any camera that has not been assigned to a group (0 in C/ M Group field in step 1).

2

ADDENDUM — (9/02)

Image 3
Contents Addendum Camera Access for Viewing C/M Group Camera AccessAddendum 9/02 Camera Access for PTZ Control C/C Group Addendum 9/02 PTZ Control Through a Genex Multiplexer ON-SCREEN Character Blinking Compatibility with CM9760-SAT Satellite Switchers