Pelco C1306M-D (7/09) manual On next

Page 8

Table A. P Protocol Receiver Address

 

 

 

 

SWITCH SETTING

 

 

 

ADDRESS

SW1-1

SW1-2 SW1-3

SW1-4 SW1-5

SW1-6

SW1-7

SW1-8

1

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

2

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

3

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

4

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

5

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

6

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

7

OFF

ON

ON

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

8

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

9

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

10

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

11

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

12

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

13

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

14

ON

OFF

ON

ON

OFF

OFF

OFF

OFF

15

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

16

ON

ON

ON

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH SETTING

 

 

 

 

 

 

 

 

 

ADDRESS

SW1-1 SW1-2

SW1-3

SW1-4 SW1-5

SW1-6 SW1-7

SW1-8

17

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

18

ON

OFF

OFF

OFF

ON

OFF

OFF

OFF

19

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

20

ON

ON

OFF

OFF

ON

OFF

OFF

OFF

21

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

22

ON

OFF

ON

OFF

ON

OFF

OFF

OFF

23

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

24

ON

ON

ON

OFF

ON

OFF

OFF

OFF

25

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

26

ON

OFF

OFF

ON

ON

OFF

OFF

OFF

27

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

28

ON

ON

OFF

ON

ON

OFF

OFF

OFF

29

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

30

ON

OFF

ON

ON

ON

OFF

OFF

OFF

31

OFF

ON

ON

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

32

ON

ON

ON

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

Table B. D Protocol Receiver Address

 

 

 

 

 

SWITCH SETTING

 

 

ADDRESS

 

SW1-1

SW1-2

SW1-3

SW1-4 SW1-5

SW1-6 SW1-7

1

 

ON

OFF

OFF

OFF

OFF

OFF

OFF

 

2

 

OFF

ON

OFF

OFF

OFF

OFF

OFF

3

 

ON

ON

OFF

OFF

OFF

OFF

OFF

4

 

OFF

OFF

ON

OFF

OFF

OFF

OFF

5

 

ON

OFF

ON

OFF

OFF

OFF

OFF

6

 

OFF

ON

ON

OFF

OFF

OFF

OFF

7

 

ON

ON

ON

OFF

OFF

OFF

OFF

8

 

OFF

OFF

OFF

ON

OFF

OFF

OFF

9

 

ON

OFF

OFF

ON

OFF

OFF

OFF

10

 

OFF

ON

OFF

ON

OFF

OFF

OFF

11

 

ON

ON

OFF

ON

OFF

OFF

OFF

12

 

OFF

OFF

ON

ON

OFF

OFF

OFF

13

 

ON

OFF

ON

ON

OFF

OFF

OFF

14

 

OFF

ON

ON

ON

OFF

OFF

OFF

15

 

ON

ON

ON

ON

OFF

OFF

OFF

16

 

OFF

OFF

OFF

OFF

ON

OFF

OFF

17

 

ON

OFF

OFF

OFF

ON

OFF

OFF

18

 

OFF

ON

OFF

OFF

ON

OFF

OFF

19

 

ON

ON

OFF

OFF

ON

OFF

OFF

20

 

OFF

OFF

ON

OFF

ON

OFF

OFF

21

 

ON

OFF

ON

OFF

ON

OFF

OFF

22

 

OFF

ON

ON

OFF

ON

OFF

OFF

23

 

ON

ON

ON

OFF

ON

OFF

OFF

24

 

OFF

OFF

OFF

ON

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

SW1-8

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

 

 

 

 

SWITCH SETTING

 

 

 

 

 

 

 

 

 

ADDRESS

SW1-1 SW1-2

SW1-3

SW1-4 SW1-5

SW1-6

SW1-7 SW1-8

25

ON

OFF

OFF

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

26

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

27

ON

ON

OFF

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

28

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

29

ON

OFF

ON

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

30

OFF

ON

ON

ON

ON

OFF

OFF

OFF

31

ON

ON

ON

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

32

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

33

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

34

OFF

ON

OFF

OFF

OFF

ON

OFF

OFF

35

ON

ON

OFF

OFF

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

36

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

37

ON

OFF

ON

OFF

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

38

OFF

ON

ON

OFF

OFF

ON

OFF

OFF

39

ON

ON

ON

OFF

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

40

OFF

OFF

OFF

ON

OFF

ON

OFF

OFF

41

ON

OFF

OFF

ON

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

42

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

43

ON

ON

OFF

ON

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

44

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

45

ON

OFF

ON

ON

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

46

OFF

ON

ON

ON

OFF

ON

OFF

OFF

47

ON

ON

ON

ON

OFF

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

48

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

(Continued on next page)

8

C1306M-D (7/09)

Image 8
Contents ExSite Ehxm Series Explosionproof Fixed System List of Tables ContentsList of Illustrations Important Safety Instructions Methods of Installation Getting StartedInstall the Power Module Attach Power Module to Mounting SurfaceConnect Wiring Configuration of Wire HarnessDIP Switch Settings Protocol SettingsOn next Address SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 239 Install the Camera Module Remove Back Cap of Camera EnclosureInstall Camera Module SET TAB Center Position Install the Enclosure and Set Pan Position Factory-Installed Power Module SealSet the Tilt Angle of the Camera Module Install the Sun Shroud Install the Sun ShroudMaintenance Camera Module ReplacementInstall Camera Module C1306M-D 7/09 Specifications ElectricalCAMERA/OPTICS Camera Day/Night 23X Color LowLight 22X ColorProduct Warranty and Return Information

C1306M-D (7/09) specifications

The Pelco C1306M-D is a performance-driven camera designed for comprehensive surveillance applications, notable for its robust features and reliability. Launched in July 2009, the C1306M-D has been a popular choice in the security industry, primarily due to its technological advancements and user-friendly operation.

One of the key features of the C1306M-D is its advanced image sensor. The camera utilizes a high-resolution CCD sensor that delivers exceptional image quality, ensuring that users capture detailed and vibrant images even in challenging lighting conditions. Coupled with its adaptive signal processing technology, the camera enhances illumination levels, which significantly improves visibility in low-light environments.

A vital characteristic of the C1306M-D is its versatile lens options. The camera supports various lenses, allowing users to tailor their surveillance systems according to specific monitoring needs. Whether it’s for wide-area surveillance or detailed examination of specific locations, the interchangeable lens feature offers flexibility and adaptability.

In terms of construction, the Pelco C1306M-D is built with robust materials that ensure durability. Its weather-resistant housing makes it ideal for both indoor and outdoor installations, capable of withstanding harsh environmental conditions. This durability extends the camera’s lifespan, making it an excellent long-term investment for security operations.

The C1306M-D is equipped with advanced connectivity options, facilitating seamless integration into existing security systems. Its compatibility with various video formats and protocols enables easy integration with digital video recorders (DVRs) and network video recorders (NVRs). Additionally, the camera supports remote viewing capabilities, allowing users to monitor feeds in real time from anywhere through an internet connection.

Another noteworthy technology in the Pelco C1306M-D is its motion detection feature, which triggers alerts or recording when movement is detected within the camera’s field of view. This proactive approach ensures that security teams can respond promptly to any abnormal activity.

In summary, the Pelco C1306M-D represents a combination of advanced technology, user-centric design, and efficient performance. Its high-resolution imaging, flexible lens options, robust construction, and strong connectivity make it a compelling choice for organizations looking to enhance their surveillance capabilities. With its introduction back in July 2009, the camera continues to stand out in an industry that increasingly demands high quality and reliability.