American Standard M968498 warranty Mount Enclosure Fig, Connect Spout Hose to Enclosure Fig

Page 4

2 MOUNT ENCLOSURE; Fig. 2

1.Determine location of ENCLOSURE (1). It must be located with-in the 14" (356mm) by 21" (533mm) shaded area shown in Figure 2 in order for electrical connections from the spout assembly to be made.

NOTE: ENCLOSURE SUPPLY HOSE is 20". Distance between wall supply and ENCLOSURE (1) must be taken into consideration.

2.Remove 4 screws from COVER (2) and pull off COVER (2). Hold the ENCLOSURE (1) in desired location and mark the four mounting hole locations as shown. Fig. 2.

3.The ENCLOSURE (1) works best if secured to a wall stud or cross brace within the wall, using the SCREWS

(3) supplied. If the ENCLOSURE (1) is to be installed on a tile or plaster wall the ANCHORS (4) and SCREWS

(3) should be used.

4.For installations on drywall or tiled walls; use ANCHORS (4) and SCREWS (3) for securing ENCLOSURE (1) to finished wall. Drill four 1/4" dia. holes a minimum of 1-3/4" deep. Insert the four ANCHORS (4) flush with face of the finished wall. Align the ENCLOSURE (1) and Install the MOUNTING SCREWS (3). Tighten to secure ENCLOSURE (1) to mounting surface.

3CONNECT SPOUT HOSE TO ENCLOSURE; Fig. 3

1.Connect SUPPLY NUT (1) from spout assembly to nipple on top of ENCLOSURE (2). Tighten with adjustable wrench to make a water tight connection.

Fig. 3.

4CONNECT WATER SUPPLY TO ENCLOSURE AND WALL SUPPLY; Fig. 4

NOTE; If using the optional Mixing Valve See Sheet #M968808 for installation instructions.

1.Insert FIBER WASHER (4) into SUPPLY NUT (1) on ENCLOSURE (2).

2.Connect SUPPLY NUT (1) on ENCLOSURE (2) to FLEXIBLE SUPPLY HOSE (3). Tighten to make a water tight connection. Use two wrenches to tighten if necessary. Fig. 4.

3.Connect FLEXIBLE SUPPLY (3) directly to wall supply. Connection on FLEXIBLE SUPPLY (3) is 3/8" compression. Use adjustable wrench to tighten connection. Do not over tighten. Fig. 4a.

Note: FLEXIBLE SUPPLY (3) measures 20" from the bottom of the ENCLOSURE (1) base. If additional supply length is required, installer must purchase parts separately.

Important: If FLEXIBLE SUPPLY (3) is too long, loop to avoid kinking.

Fig. 2

 

 

 

LAVATORY RIM OR

 

 

 

 

 

 

 

 

MOUNTING SURFACE

 

 

 

14"

 

 

 

 

(356mm)

 

 

1

 

 

ENCLOSURE

SUPPLIES

 

 

MOUNTING

 

 

 

 

HOLES

 

 

 

 

2-3/4"

 

 

 

 

(71mm)

 

 

 

1524mm

 

WASTE

 

20"

(60)

 

 

 

 

 

(500mm)

 

 

 

21"

 

3"

3-3/4"

 

(mm)

 

(76mm)

(96mm)

MOUNTING HOLES

 

 

 

 

3

 

 

 

 

 

1

 

4

 

 

2

 

 

 

 

 

1

 

 

 

 

NOTE: If using Mixing Valve (optional) See Sheet #M968808 for installation instructions.

Fig. 3

1

 

 

 

 

2

 

Fig. 4

 

 

 

2

1

 

 

4

 

 

3

Fig. 4a

 

 

 

 

COLD WATER OR

 

 

TEMPERED

 

 

WALL SUPPLY

 

 

3

3

Image 4
Contents Innsbrook Lavatory Faucet With Selectronic Technology Unpacking ProductInstallation Roughing-in DimensionsInstall Spout Assembly Fig Tools Required FigConnect Spout Hose to Enclosure Fig Mount Enclosure FigConnect Water Supply to Enclosure and Wall Supply Fig JHB JHC JHD   JHDJHE JHF   $7&34*0/JH JHEJHH JHBJHC   JHE  6OJU 6OJU  03$7&34*0 00,61 JH 0850*/45--/%$/& #55&3JH JHJH JHB JH1HOW to Clean and Remove the Aerator Fig HOW to Clean Filter FigGeneral Cleaning Fig Faqs Selectronic M968498 Rev