Slant/Fin GXHA, GG Vent Dampers, With ANY Vent Damper Or Pilot System, Safety Information

Page 7

VENT DAMPERS

A Slant/Fin vent damper is available only as part of a Slant/Fin gas boiler package equipped with a 24 volt gas valve. This vent damper is design certified by A.G.A. for use only on specific Slant/Fin Corporation gas boiler models.

These boilers will be equipped with a plate which states that the boiler may be used with a Slant/Fin Corp. auto- matic vent damper device and indicates the proper vent damper model number.

OTHER VENT DAMPER OR DEVICES WITH SIMILAR PURPOSE ARE NOT PERMITTED.

WITH ANY VENT DAMPER

OR PILOT SYSTEM

(a)DO NOT attempt to install or adjust or service it yourself.

(b)Make certain that the installation is approved by your local gas utility.

IGNITION SYSTEM—CONTINUOUS BURNING (STANDING) PILOT

Your gas boiler is equipped with the Honeywell VR8200 or VR8300 gas valves. See Safety and Lighting Instructions on pages 7 and 8 and Figure 22.

SAFETY AND LIGHTING INSTRUCTIONS

FOR IGNITION SYSTEMS EQUIPPED WITH GAS VALVES VR8200 AND VR8300

SAFETY INFORMATION

For Your Safety Read Before Lighting

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instruc- tions exactly.

Figure 22. Continuous (Standing) Pilot

Ignition System

WARNING

Should overheating occur or the gas supply fail to shut off, DO NOT turn off or disconnect the electric supply to the circulator pump. Instead, shut off the gas supply at a location EXTERNAL to the appliance.

Your gas boiler must be installed and serviced by a qualified service agency or gas supplier. The lack of proper service can result in a dangerous condition.

7

Image 7
Contents What to do if YOU Smell GAS User’s Information ManualWith Integral Draft Diverter Sentry S Series HOT Water BoilerWith External Draft Hood Sentry SX Series HOT Water BoilerSee lighting instructions on Galaxy GG/GX Gxha Series HOT Water and Steam BoilerUser inspection Service Inspection With ANY Vent Damper Or Pilot System Safety and Lighting InstructionsSafety Information Vent DampersTo Turn OFF GAS to Appliance Lighting Instructions

GXH, GG, GX, GXHA specifications

Slant/Fin, a leader in heating technology, has developed a range of hydronic baseboard heaters, including the GXH, GX, GXHA, and GG models. These baseboard heaters are designed to deliver efficient, comfortable heating while ensuring durability and versatility in various applications.

The Slant/Fin GXH series is known for its high performance in both residential and commercial settings. One of the standout features of the GXH models is their enhanced heat output, which is achieved through a unique design that maximizes water flow. This means that even in larger spaces, the GXH can provide consistent warmth efficiently. The construction is robust, utilizing high-quality materials that ensure longevity, making these heaters a dependable choice.

The GX series focuses on versatility, with a design that allows for easy installation in a variety of settings. These models can be configured for hot water or steam systems, providing flexibility for different heating requirements. The GX series is available in various lengths and heights, making it adaptable to various room sizes and aesthetic preferences. Its sleek design seamlessly integrates into any environment, ensuring that functionality does not compromise style.

The GXHA model further enhances efficiency with its special air venting technology, which reduces air pockets within the heating system. This technology ensures that water circulates freely, enhancing heating efficiency while also reducing noise levels. The GXHA is particularly suited for environments where quiet operation is necessary, making it ideal for bedrooms or quiet offices.

The GG model, while sharing many features with the GX series, is geared towards affordability without compromising on quality. It is designed for budget-conscious consumers who still want reliable heating performance. The GG models are easy to install and maintain, featuring straightforward designs that simplify service over the years.

All models in the Slant/Fin heating line prioritize energy efficiency, allowing homeowners and businesses to enjoy lower utility costs. Additionally, the company's commitment to innovation ensures that all units meet or exceed current energy standards. Overall, the Slant/Fin GXH, GX, GXHA, and GG models offer reliable, efficient heating solutions suitable for various residential and commercial heating needs, making them a sound investment for long-term comfort.