Slant/Fin KCS50, KCS100 manual Description KC-50 KC-100

Page 2

Ref

 

Description

KC-50

KC-100

34A

 

1/4 Turn Receptacle

650542

650542

35

 

Air Orifice Adapter

660031

660031

36

 

Air Orifice Plate*

660191

660192

37

 

Air Orifice Gasket

660410

660410

38

 

Burner Enclosure

660021

660022

39

 

Barbed Fitting - 3/16" Tubing

650600

650600

40

 

Barbed Fitting - 1/8" Tubing

660596

660596

41

 

Burner Enclosure Seal

660441041

660441044

42

 

Burner Thumb Nut

660608

660608

43

 

Burner Hold-down Spring

650512

650512

44

 

Burner Ground Wire

660654

660654

45

 

Burner Compression Bracket

665101

665102

46

 

Ceramic Burner

660511

660512

47

 

Burner Ground Strip

660503

660503

48

 

Burner Seal Gasket

660431

660432

49

 

Gas Tube

660179

660179

50

 

3/4 NPT x 8" Long Gas Manifold Pipe

460514

460514

51

 

3/4 Angle Flange

660032

660032

52

 

3/4 Straight Flange

660033

660033

53

 

Convertible Gas Orifice Plate*

660181

660182

54

 

Socket Head Screw 8-32 x 2-1/4"

660631

660631

54

 

Socket Head Screw 8-32 x 1-1/2"

660632

660632

55

 

8-32 Hex Nut

650668

650668

60

 

Wall Mounting Panel

651714

651714

61

 

Boiler Support - Right Side

650233

650233

62

 

Boiler Support - Left Side

650234

650234

63

 

Expansion Tank Upper Strap

650221

650221

64

 

Expansion Tank Lower Strap

651711

651712

65

 

Jacket Top Screen

650218

650219

66

 

Jacket Brace Assembly

651118

651118

67

 

Jacket Upper Cover Clip

650733

650733

68

 

Jacket Removable Side Panel

650216

650217

69

 

Jacket Left Side Panel

651721

651722

70

 

Jacket Right Side Panel

651723

651724

71

 

Jacket Lower Cover Clip

650742

650742

72

 

Jacket Bottom Brace

650215

650215

73

 

Front Cover Panel - Black

650971

650971

73

A

Front Cover Panel - White

650972

650972

73

B

Front Cover Panel - Gray

650973

650973

73

C

Front Cover Panel - Off-white

650974

650974

 

 

 

 

 

*Note: These Prodigy boiler models utilize the same air and gas orifices as the Concept series of boilers. Therefore, the model number shown on the orifice plates reflect the Concept boiler model’s identification. (Prodigy KCS-50 uses orifice plates marked “45” and KCS-100 uses orifice plates marked “90”.)

Optional Boiler Calibration Equipment:

Calibration Gage Kit . . .665185 . . . .0 to 1” gage on stand with tubing and service fitting adapters. Service Fitting Adapter .660533 . . . .for gages with 3/16" I.D. tubing.

2

Image 2
Contents Boiler Replacement Parts List Description KCS-50 KCS-100Description KC-50 KC-100 Page Description Slant/Fin Heat Fab SLANT/FIN CORPORATION, Greenvale, N.Y Phone 516

KCS100, KCS50 specifications

Slant/Fin KCS100 and KCS50 are advanced, high-performance gas-fired condensing boilers designed for residential and light commercial applications. These models are part of Slant/Fin's commitment to energy efficiency and eco-friendly heating solutions, providing users with optimal comfort and significant energy savings.

The KCS100 features a robust heating capacity of up to 100,000 BTUs per hour, making it suitable for larger spaces. In contrast, the KCS50 offers a slightly lower capacity, with a maximum output of 50,000 BTUs per hour, ideal for smaller homes or specific heating zones. Both models excel in their compact, space-saving design, allowing for easy installation in tight spaces often encountered in residential settings.

One of the standout technologies in both the KCS100 and KCS50 is their modulating gas valve. This innovative feature allows the boilers to adjust their output based on real-time heating demands, thus maximizing efficiency and minimizing energy waste. Furthermore, these models utilize a stainless steel heat exchanger that enhances durability and improves overall thermal efficiency, providing a longer lifespan and reduced maintenance requirements.

In terms of efficiency, the KCS series boasts an impressive AFUE (Annual Fuel Utilization Efficiency) rating, reaching up to 95%. This means that a significant portion of the fuel consumed is converted into usable heat, translating into lower energy bills for users. Additionally, the advanced condensation technology captures heat from exhaust gases, further boosting efficiency and making these boilers environmentally friendly.

The KCS100 and KCS50 are designed with user convenience in mind. They come equipped with an intuitive control panel, allowing homeowners to easily adjust settings and monitor operation status. Moreover, both models support a range of integration options with existing heating systems, ensuring seamless functionality whether installed as a primary or supplemental heat source.

Safety features are also a priority in the KCS series. They include built-in safety controls that monitor temperature and pressure, helping to prevent potential hazards during operation. This ensures not only a reliable heating solution but also peace of mind for users.

In summary, Slant/Fin's KCS100 and KCS50 gas-fired condensing boilers combine cutting-edge technologies, high efficiency, and user-friendly features, making them excellent choices for anyone seeking reliable, cost-effective heating solutions.