American Standard 4101.301 installation instructions Test Installed Faucet, Service

Page 4

5 TEST INSTALLED FAUCET

Move HANDLE (1) down into "off" position.

Remove AERATOR (2).

Operate handle up and down, in COLD and HOT positions, to flush water lines thoroughly.

Replace AERATOR (2).

1

With HANDLE (1) down in "off" position, pull HAND SPRAY (3) from holder and direct SPRAY END (3) into sink.

Check HAND SPRAY (3) operation:

2

With faucet on push BUTTON (4) to activate HAND SPRAY (3).

Release BUTTON (4) to stop spray and return

HAND SPRAY (3) to holder.

 

4

 

3

6 SERVICE

3

If faucet drips, operate HANDLE several times from "off" to "on." Do not

2

apply excessive force.

1

Clogged CARTRIDGE outlets or inlets may cause reduced flow.

To clean, first turn off water supply then:

4

Remove INDEX BUTTON (1), loosen HANDLE SCREW (2)

 

and remove HANDLE (3).

 

Unthread ESCUTCHEON CAP (4). Unthread three

 

MOUNTING SCREWS (5).

 

Lift CARTRIDGE (6) off MANIFOLD (7) and remove

5

CARTRIDGE SEALS (8).

Clean MANIFOLD (7), CARTRIDGE (6) ports and SEALS (8).

Place SEALS (8) into CARTRIDGE PORTS (6a).

Place CARTRIDGE (6) onto MANIFOLD (7) and tighten MOUNTING

 

6

SCREWS (5) alternately.

6a

8

Replace ESCUTCHEON CAP (4), HANDLE (3), tighten HANDLE

SCREW (1) and install INDEX BUTTON (2).

7

 

Test fitting.

 

 

7 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

M 9 6 8 5 8 3

Image 4
Contents Install Faucet with Deck Escutcheon 4101.351Install Faucet Without Escutcheon Plate With soap dish 4101.350 less soap dishMake Water Supply Connections ColdConnect Spray Hose and Spout Hose Check Connections for LeaksService Test Installed FaucetClogged Cartridge outlets or inlets may cause reduced flow HI-FLOW Kitchen Faucet