American Standard 7871.732 POP-UP Drain, Remove Flange, Install Drain from, Below Fixture

Page 2

2 POP-UP DRAIN

Remove CLEAR PLASTIC COVER (1).

Remove CARDBOARD SPACER (2) from under DRAIN POP-UP (3).

Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY. Fig. B.

Fig. A.

1

3

2

Fig. B.

DRAIN

BODY

4

3 REMOVE FLANGE

Thread FLANGE (1) counter-clockwise and remove FLANGE (1) and FOAM GASKET (2) from drain

body. Fig. A.

Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against LOCKNUT (3). Fig. B.

Fig. A.

1

2

Fig. B.

4

3

4

INSTALL DRAIN FROM

BELOW FIXTURE

REAR OF SINK

5 TIGHTEN LOCKNUT

From under side of SINK install DRAIN BODY (1) up through drain outlet.

Note: No plumber’s putty or caulk is required.

The CABLE ATTACHMENT POINT (2) must face towards the rear of the SINK.

Install FOAM GASKET (3) and FLANGE (4) onto drain body from above SINK and tighten FLANGE (4) firmly.

4

3

DRAIN OUTLET

1

2

Tighten LOCKNUT (1) firmly with Adjustable Wrench or Channel Locks.

1

6 FLANGE GASKET AND POP-UP KNOB

Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET (3) is fully compressed and not visible. Fig. A.

POP-UP KNOB (1) must be fully down. Fig. B.

Fig. A.

WHITE FOAM

 

GASKET

DRAIN

NOT VISIBLE

FLANGE

Fig. B. DOWN

1

U S 6 0 4 0 4 R e v. 1 . 2

2

Image 2
Contents Spread Lavatory Faucet with Speed Connect Drain Install Spout1A Install Valve Body Remove Flange Install Drain fromPOP-UP Drain Below FixtureMake Water Supply and Waste Connections Attach Cable ConnectorCheck Operation of POP-UP ColdTest Installed Fitting Check Drain ConnectionsTroubleshooting Guide Cable Adjustment ProcedureUnlocked Mode Locked Mode Vandal Proof