Rinnai Q205S, Q175S specifications Standard Features Optional Accessories, Specifications

Page 1

Q175S / Q205S Condensing Boiler

Standard Features

Optional Accessories

Onboard outdoor reset control system with sensor standard

Prebuilt plumbing kit with insulated Low Loss Header

Priority DHW standard (3 way valve not included)

Domestic hot water plate warming

Modulating Ceramic premix burner

5:1 turn down ratio

Spark ignition

Exceeds SCAQMD 1146.2 Low NOx requirements

Stainless Steel Water tube condensing heat exchanger

Direct Vent sealed combustion

Concentric and twin pipe venting adapters included

Approved for room and closet installations

3 way valve DHW kit

RS100 Single zone controller

Flue Gas temperature sensor

Room Air Filter

NG to LP conversion Kit

LP to NG Conversion Kit

SPECIFICATIONS

General Specifications

 

 

Boiler

Boiler

 

Units

Model

Model

 

 

Q175S

Q205S

 

 

 

 

Water content

gal

1.8

1.8

 

 

 

 

Max. supply boiler

°F

176

176

temperature

 

 

 

 

 

 

 

Max operating pressure

psi

45

45

 

 

 

 

Relief valve rating

MBH

375

375

 

 

 

 

Relief valve pressure rating

psi

30

30

 

 

 

 

Dry weight

lbs

141

141

 

 

 

 

Min inlet gas pressure NG

"W.C.

4.0"

4.0"

 

 

 

 

Max inlet gas pressure NG

"W.C.

10.5"

10.5"

 

 

 

 

Min inlet gas pressure LP

"W.C.

8.0"

8.0"

 

 

 

 

Max inlet gas pressure LP

"W.C.

14.0”

14.0”

 

 

 

 

Max equivalent exhaust

ft

80

40

vent length

 

 

 

Max equivalent combustion

ft

80

40

air vent length

 

 

 

 

 

 

 

 

 

Polypropylene,

Approved venting materials

 

Stainless Steel,

 

 

PVC, CPVC

Performance Specifications

 

Units

Boiler Model

 

 

 

 

Q175S

Q205S

 

 

 

 

 

 

Fuel Type

 

NG/LP

NG/LP

 

 

 

 

Input

MBH

175

205

 

 

 

 

Heating Capacity

MBH

161

189

 

 

 

 

AFUE (I=B=R)

%

95.7

95.7

 

 

 

 

Part Load Efficiency

%

98.5

98.5

(EN677)

 

 

 

Electrical Specifications

 

Units

Boiler Model

 

 

 

 

Q175S

Q205S

 

 

 

 

 

 

Electrical Voltage Mains

V/Hz

120/60

120/60

 

 

 

 

Electrical Voltage Controls

V

24

24

 

 

 

 

Power Consumption Max

W

210

234

Load

 

 

 

Power Consumption Stand

W

14

14

by Load

 

 

 

Recommended Circuit

A

15

15

breaker rating

 

 

 

Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.

© 2011 Rinnai Corporation

Q175S / Q205S SP

2/2011

Image 1