Rinnai Q175S, Q205S specifications Dimensions, Clearances

Page 2

Q175S / Q205S

DIMENSIONS

2.0” 50mm

15”

381mm

4.7” 10.2”

120mm 260mm

 

 

Q175S, Q205S

 

 

 

 

 

inch / mm

 

 

 

 

A

Height

26.8

/ 680

 

 

 

B

Width

26 / 660

 

 

 

 

C

Depth

15.2

/ 385

 

 

 

 

D

Left side / vent

19.5

/ 495

 

 

 

 

E

Center to center / vent and air

4.7 / 120

supply

 

 

 

F

Back / vent

10.6

/ 270

 

 

 

 

G

Left side / gas pipe

2.6

/ 65

 

 

 

H

Left side / supply pipe

7.3 / 185

 

 

 

 

J

Left side / return pipe

17.5

/ 445

 

 

 

 

K

Left side / condensate pipe

20.9

/ 530

 

 

 

 

P

Pipe length of g

0.7

/ 18

 

 

 

Q

Pipe length of c

2 / 50

 

 

 

 

R

Pipe length of e, f, k, r, and w

2.3

/ 60

 

 

 

S

Back / center of pipe c

1 / 25

 

 

 

 

T

Back / Center of pipe g

1.6

/ 40

 

 

 

 

U

Back, / center of pipe e, f, k, r,

2 / 50

and w

 

 

 

 

 

 

 

V

Pipe length vent co-axial

2.6

/ 65

Pipe length vent parallel

5.8 / 147

 

 

 

 

 

Clearances

18.6”

474mm

2.1” 54mm

[5.6”

142mm

5.2”

 

12”

133mm

17.2”

305mm

 

438mm 19.7”

 

 

501mm

 

Minimum required

Recom-

 

clearance to

mended

 

combustibles and

service

 

non-combustibles

clearances

 

 

 

 

inch / mm

inch / mm

 

 

 

 

 

Top

2

/ 50

10

/ 250

 

 

 

 

 

Back

 

0

 

0

 

 

 

 

Front

6 / 150

24

/ 600

 

 

 

 

 

Left side

2

/ 50

2

/ 50

 

 

 

 

 

Right

2

/ 50

2

/ 50

side

 

 

 

 

 

 

 

 

 

Floor /

12

/ 300

30

/ 762

Ground

 

 

 

 

 

 

 

 

 

Vent

 

0

 

0

 

 

 

 

 

Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us