Rinnai RHFE-263FA II manual Safety Symbols, Technical Data, High Altitude Installation

Page 2

Safety Symbols

This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.

Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. It may also be used to alert against unsafe practices.

Technical Data

Weight 37 lbs (16.8kg)

Dimensions

Width

16

3/4 in (425mm)

 

 

Height

26

5/8 in (676.5mm)

 

 

Depth

9 13/16 in (250mm)

 

Natural Gas

Propane Gas

Minimum supply gas pressure

3.5 in (89mm) W.C.

8.0in (203mm) W.C.

 

 

 

Maximum supply gas pressure

10.5 in (267mm) W.C.

13.0 in (330mm) W.C.

 

 

 

Manifold test pressure (Low)

0.6 in (16mm) W.C.

1.1 in (27mm) W.C.

 

 

 

Manifold test pressure (High)

2.3 in (58mm) W.C.

3.7 in (94mm) W.C.

 

 

 

High Altitude - Manifold test pressure (Low)

0.6 in (16 mm) W.C

1.1 in (27 mm) W.C.

 

 

 

High Altitude - Manifold test pressure (High)

1.7 in (42 mm) W.C.

2.7 in (68 mm) W.C.

 

 

 

BTU/hour input

Low 5500 - High 11000

Low 5700 - High 11000

 

 

 

BTU/hour output

Low 4450 - High 8800

Low 4600 - High 8800

 

 

 

Injector

AU129-210-1.30

AU129-210-0.90

0.051 in (1.30mm)

0.035 in (0.90mm)

 

 

 

 

Primary damper

308F-209-13

308F-209-7

 

 

 

Secondary damper

308F-218-1 (Φ3.0×10)

308F-218-3 (Φ2.5×10)

 

 

 

The input rate can be verified by following the procedure in the National Fuel Gas Code (NFPA54 / ANSI Z223.1, 2006 or latest edition).

High Altitude Installation

Conversion of the appliance for operation at high altitudes (> 2000 ft, 610 m) requires the completion of the section, Adjust Gas Pressure Settings, using the high altitude manifold test pressures above. No parts need to be replaced for high altitude.

For high altitude installations in Canada, the conversion shall be carried out by a manufacturer’s authorized representative, in accordance with the requirements of the manufacturer, provincial or territorial authorities having jurisdiction and in accordance with the requirements of CAN/CGA-B149.1 or CAN/CGA-B149 installation codes.



Rinnai Corporation RHFE-263FAConversion Manual

Image 2
Contents RHFE-263FAⅡ High Altitude Installation Safety SymbolsTechnical Data Replace Components Conversion ProcedureGain Access Adjust Gas Pressure Settings Normal Operating Sequence Sécurité Du Consommateur Haute Altitude Installation Données TechniquesRemplacer des Composants Procédure de ConversionGagner lAccès Ajustage et Reglage de la Presion de Gas Eteindre le gaz et le pouvoir fournitLa Séquence normale dOpération LPG 308F-2073

RHFE-263FA II specifications

The Rinnai RHFE-263FA II is a state-of-the-art gas heater designed to provide warmth and comfort in residential spaces. Renowned for its innovative technology and reliability, this model stands out for its energy efficiency and user-friendly features, making it an ideal choice for homeowners seeking an effective heating solution.

One of the key characteristics of the RHFE-263FA II is its powerful heating capacity, which can efficiently warm up spaces up to 40 square meters. This makes it suitable for a range of room sizes, from cozy bedrooms to larger living areas. The unit operates on natural gas, delivering consistent heating without the need for bulky external storage tanks.

The design of the unit is both sleek and compact, allowing it to blend seamlessly into various interior decor styles without taking up much space. Additionally, the installation process is straightforward, and it can be mounted conveniently on walls, making it an excellent choice for homeowners with limited floor space.

In terms of technology, the Rinnai RHFE-263FA II employs advanced combustion technology that ensures optimal fuel efficiency while minimizing emissions. This is particularly important in today’s environmentally conscious world, where reducing carbon footprints is a priority. The unit also features a quiet operation mode, ensuring that it helps maintain a peaceful environment while running.

The heater is equipped with an intelligent control system that allows users to set a desired temperature, and it will automatically adjust its operation to maintain that level. This not only enhances comfort but also promotes energy savings, as the heater won’t operate unnecessarily when the desired warmth has been achieved.

Remote control functionality further elevates user convenience. Homeowners can easily adjust the temperature settings from anywhere in the room, enhancing comfort and providing ease of access.

Safety features are also a priority in this model, with built-in protections against overheating and gas leaks. The RHFE-263FA II adheres to stringent safety standards, ensuring that users can enjoy its benefits without worry.

In summary, the Rinnai RHFE-263FA II combines powerful heating capabilities with efficient energy use, modern design, and user-friendly technology. With its emphasis on safety, comfort, and environmental responsibility, it is a top choice for those seeking reliable and effective home heating solutions.