Rinnai 26i, HD50i user manual Temperature Controls Information

Page 27

TEMPERATURE CONTROLS - INFORMATION

Do not push the On/Off button on the

 

 

Temperature priority can not be switched

Master controller after transferring priority

 

 

to another controller when the water is

of temperature selection to a Secondary

 

 

flowing through the water heater.

controller as the system will shut down.

 

 

 

 

 

 

 

 

 

Do Not Turn OFF

 

 

 

 

 

 

 

 

500C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the Master

 

 

 

 

 

 

 

 

 

 

 

 

 

Controller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controller 1

 

 

 

Controller 2

 

 

 

 

 

 

 

 

 

in use

 

 

 

cannot take

 

 

 

 

 

 

 

 

 

 

 

 

 

 

priority

If a temperature higher than 50ºC has

 

 

Do not clean the remote control with

been selected on the Master controller

 

 

solvents or detergents. Use only a soft

and priority of temperature selection is

 

 

damp cloth.

 

 

 

 

 

transferred to another controller (or it is

 

 

 

 

 

 

 

 

 

turned off), then back again (or turned on

 

 

 

 

 

 

 

 

 

again), the temperature on the Master

 

 

 

 

 

 

 

 

 

controller will automatically drop to 50ºC.

 

 

 

 

 

 

 

 

 

If the set point is less than 500C it will not

 

 

 

 

 

 

 

 

 

alter. This is a safety feature.

 

 

 

 

 

 

 

 

 

 

 

 

Master

Another

Master

 

 

 

 

 

 

 

 

 

Controller

Controller

Controller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depending on the weather conditions

 

 

If a temperature higher than 420C has

and the length of the pipe between the

 

 

been selected on the Universal control-

heater and the tap in use, there may be a

 

 

ler and priority of temperature selection is

variation between the temperature dis-

 

 

transferred to another controller (or con-

played at the controller and the tempera-

 

 

troller is turned OFF), then back again (or

ture at the tap.

 

 

 

 

 

 

turned ON again), the temperature will

 

 

 

 

 

 

 

 

 

automatically drop to 420C. If the set

 

 

 

 

 

 

 

 

 

point is less than 420C it will not alter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This is a safety feature.

 

 

 

 

 

 

 

 

480C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Universal

Another

Universal

 

 

 

 

 

 

 

 

 

Controller

Controller

Controller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27

 

 

 

 

 

 

Image 27
Contents Infinity 26i and HD50i Standard Use Rinnai UK Warranty from JanContents Quantity Description Remote Control Parts Unpacking Rinnai Water HeaterUnit Mounting Fasteners Important Information Installation InstructionsAppliance Location Installation Instructions PositioningGeneral Information Installation Instructions VentilationGas Connection Installation Instructions ConnectionsWater Supply Water ConnectionFlue Requirements Positioning General Flue Requirements InstallingDimensions Infinity HD50i Technical DetailsOperating Noise Level is Very LOW Features and BenefitsImportant Information OFF Turn On by opening the hot water tap Operation Without RemotesTemperature Controls General Universal Temperature Controller Temperature Controls InstallationConnecting One or Two Controllers Connecting Three ControllersConnecting Four Controllers Temperature Controls Temperature Controls Operating Adjusting Temperature Using 1 Universal Temperature ControllerBathroom temperatures should be no more than 500C Using 2 or more Universal Temperature ControllersSwitching the system on Using hot waterStep Using 4 Universal Temperature ControllersUsing High Temperature Display Controllers To turn off your hot water system Additional safety featuresTemperature Controls Information Testing LPG GAS Pressure SettingLPG MbarDip Switch Positions Explained DIP Switch SettingTemperatures Remotes Connected Temperatures With or Without Remotes ConnectedCode Fault Remedy Displayed Error MessagesInstallations with circulation pumps With temperature controller fittedWithout temperature controller fitted Standard system Restarting the Rinnai Water HeaterWiring Diagram Diagnostic Points Electrical Supply…………………………….…………..…………….….230V AC 50Hz 1ph SpecificationService Contact Commissioning Check List

26i, HD50i specifications

The Rinnai 26i and HD50i are two high-efficiency heating solutions designed to meet modern demands for comfort, convenience, and energy saving. These units are ideal for residential heating applications, delivering reliable warmth while also being mindful of environmental impacts and energy consumption.

The Rinnai 26i is a wall-mounted unit that offers exceptional performance and efficiency. With a compact design, it is perfect for both small and large spaces, making it versatile in various settings. One of the standout features of the 26i is its ability to provide continuous hot water and space heating simultaneously, making it exceptionally convenient for homeowners. The advanced modulation technology allows the unit to adjust its heating output based on demand, ensuring optimal comfort without excessive energy use.

Another notable aspect of the Rinnai 26i is its intelligent control system, which includes a user-friendly digital display and programmable thermostat. This allows homeowners to customize their heating schedules and maintain their preferred temperature with ease. Additionally, the unit is equipped with a range of safety features, including anti-frost protection, ensuring safe operation even in extreme weather conditions.

On the other hand, the Rinnai HD50i is designed for larger spaces and offers an impressive heat output. This gas heater features a stylish design, blending seamlessly with modern home aesthetics. The HD50i utilizes Rinnai's innovative convection technology, which effectively warms the room by circulating heated air, providing consistent comfort throughout the space.

The HD50i is also equipped with advanced airflow management systems that minimize hot and cold spots, ensuring even distribution of heat across various rooms. Both the 26i and HD50i models come with energy-efficient ratings that help reduce utility bills while lowering carbon footprints.

Ease of installation and maintenance is another advantage of both units; they are designed for straightforward setup and come with clear guidelines for servicing. This focus on user experience makes Rinnai heating systems a popular choice among homeowners.

In summary, the Rinnai 26i and HD50i represent the culmination of innovative heating technology, efficiency, and aesthetics. With their advanced features, environmental consideration, and user-friendly operation, these units stand out as top choices for efficient home heating solutions. Whether for a compact apartment or a spacious home, Rinnai provides versatile and reliable options for creating a warm, comfortable living environment.