7.4Place log D across from the rear log A to log B on the left- hand side. There are cut-outs in both logs for location. See diagram 5.

5

AR1613

7.5There are two ash panels which lay across the front of the burner skin. Place the panel with the flat edge facing the left side of the firebox. There are location holes on this log which fit over the screw holes of the burner skin.

6

AR1614

7.6Place the second ash panel to the right of the first, with the pointed end of the panel fitting into the V shape. This panel should locate on the screw holes of the burner skin. Ensure that both logs are horizontal to the burner ports.

7

AR1615

7.7Place log E across from the rear of log A to log C on the right hand side. Again, there are cut-outs for location. The front of the log should sit on the front ash panels and should fit tight to log C. See diagram 8.

8

AR1616

7.8Carefully insert the front coal retainer into the front panel of the firebox. Take care not the scrape/damage the logs. This coal retainer sits in two brackets. Ensure it is fully inserted, leaving approximately a 4 mm gap between the firebox ledge and the bottom of the coal retainer.

9

AR1617

7.9Ensure that the fibreglass seal on the back of the door is intact, locate the door on the four studs and slide back to the firebox. Secure in place using the four dome nuts and tool supplied. Do not overtigthen the nuts, see diagram 10.

10

AR0390

NEVER OPERATE THE STOVE WHEN THE DOOR IS REMOVED.

6

Image 6
Contents PR0846 Issue 2 February Marlborough & Stockton Log Effect Stove RangeContents Appliance Commissioning Checklist Flue Check Pass FailGAS Check Lighting the Stove User InstructionsGeneral Turning OFF the StoveCleaning the Fire Handling & Disposal of Fire CeramicsFuel BED Arrangements Never Operate the Stove When the Door is Removed ‘RUNNING IN’ Installation DetailsFlame Failure Device ServicingInstallation Instructions Technical SpecificationSite Requirements Flue and Chimney RequirementsTimber Framed Buildings TOP Exit Guard SuppliedOptional Extra Flue Lengths & Bends TOP Flue UP & OUT with Additional BendALL Appliances Nominal Actual Stainless AnthraciteAppliance Location Installation of the GAS SupplyVentilation Minimum ClearanceSafety Precautions InstallationControl Upgrade Installation of the StoveDo not FIX the Flue AT this Stage Vertical & Horizontal Flue Table a TOP Exit Flue Vertical and Horizontal RestrictorsVertical Flue Height Horizontal Length Restrictor Size TOP Exit Vertical Flue Table a TOP Exit Vertical only Including OffsetVertical Height Restrictor Size Fuelbed Arrangements Lighting Commissioning CommissioningServicing Requirements Servicing / Fault Finding ChartsServicing Instructions Ignition Functional CheckFlame Failure Functional Check Pilot will not Stay LIT or Fire Goes OUT in USENo Spark Replacing Parts Main BurnerPilot Unit Ignition Lead GAS Valve Magnetic Safety ValvePiezo Main InjectorPrimary Aeration Plate Changing Between GAS TypesShort Spares List Service Records Member of the Stovax Group

Stockton Log Effect Stove Range specifications

The Stovax Stockton Log Effect Stove Range is a celebrated collection that brings the warmth and ambiance of a traditional log fire into modern homes. Known for its innovative design and high efficiency, this range offers a perfect blend of style and practicality, making it a popular choice among homeowners and interior designers alike.

One of the standout features of the Stockton Log Effect Stove Range is its realistic log effect fuel bed, which creates an inviting and cozy atmosphere. This clever design simulates the look of real logs burning, providing a comforting focal point within any room. The stove is available in various sizes, ensuring that there's a model to fit any space, whether large or small.

The efficacy of the Stockton stoves is further enhanced by advanced technology that promotes efficient heat output. Many models within the range come equipped with a multi-fuel capability, allowing users to choose between burning logs, smokeless fuel, or even coal, depending on availability and preference. This versatility not only maximizes the stove's usability but also reduces reliance on one type of fuel, catering to different heating needs throughout the year.

Another attractive characteristic of the Stovax Stockton Log Effect Stove is its high efficiency rating, which ensures that more heat is extracted from the fuel while minimizing emissions. The inclusion of a clean burn technology helps to burn off gases and particles before they enter the flue, leading to a cleaner, more environmentally friendly burn. This feature not only benefits the environment but also contributes to a more efficient heating source that saves energy costs.

The aesthetic appeal of the Stockton range is further enhanced by its sleek and contemporary design. Available in a variety of finishes and colors, including traditional black and modern gray, these stoves can seamlessly blend into both traditional and contemporary interiors.

Safety is also a priority within the design of these stoves. Many models feature built-in safety measures such as a secure door mechanism and effective air controls, ensuring that users can operate the stove easily and safely.

In conclusion, the Stovax Stockton Log Effect Stove Range combines traditional design elements with modern technology and versatility. It stands out for its realistic log effect, efficiency, and safety features, making it an ideal choice for anyone looking to enhance their living space with both warmth and style.