Stovax VFC Radiant & Convector Fire Range manual Arrangement of Fuelbed Components

Page 13

INSTALLATION INSTRUCTIONS

INSTALLATION

5.9 Connect the 8mm gas supply pipe to the fire. See diagram 10.

10

AR0944

5.10Check the gas connections to the fire are sound. Light the fire and check all joints on the appliance.

5.11Check the appliance working pressure is correct. See databadge.

5.12Fit the fire trim to the convector box. See diagram 11.

11

AR0303

5.13Fit the fret to the fire front using the two securing screws. See diagram 12.

12

AR0311

5.14If the appliance is fitted with an alternative Gazco front please refer to the separate leaflet supplied with the front.

6.ARRANGEMENT OF FUELBED COMPONENTS

ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS

The fuel effect and side panels in this appliance are made from Refractory Ceramic Fibre (RCF), a material which is commonly used for this application.

Protective clothing is not required when handling these articles, but we recommend you follow normal hygiene rules of not smoking, eating or drinking in the work area and always wash your hands before eating or drinking.

To ensure that the release of RCF fibres are kept to a minimum, during installation and servicing a HEPA filtered vacuum is recommended to remove any dust accumulated in and around the appliance before and after working on it. When servicing the appliance it is recommended that the replaced items are not broken up, but are sealed within heavy duty polythene bags and labelled as RCF waste.

RCF waste is classed as stable, non-reactive hazardous waste and may be disposed of at a licensed landfill site.

Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract; wash hands thoroughly after handling the material.

NOTE: CERAMIC PARTS ARE FRAGILE.

6.1Position the flame baffle on the rear of the tray. See diagram 13 arrow B.

6.2Position the front coal, make sure it sits flat onto the burner skin. See diagram 13 arrow C.

13

6.3Place the coals following the appropriate diagrams and instructions

16” AND REDUCED DRAUGHT COAL LAYOUT

6.4Curved fronts (Holyrood and Richmond) -place 5 large coals

onto the front coal moulding ensuing that they rest against the front, place 2 small coals on to the front coal, 1 at each end. See diagram 14.

14

13

Image 13
Contents VFC Radiant & Convector Fire Range Contents Flue Check Pass Fail Appliance Commissioning ChecklistGAS Check General User InstructionsLighting the Fire Turning the Fire OFFUpgrading Your Fire Cleaning the FireArrangement of Fuel BED Components Gazco Part NumberCoal Layout Oxygen Depletion Sensor Installation DetailsFlame Failure Device 10.’RUNNING IN’MIN Flue Specification Technical SpecificationCAT Minimum Flue SizeInstallation of the GAS Supply Installation InstructionsSite Requirements Flue and Chimney RequirementsInstallation Instructions Control Upgrade InstallationSafety Precautions Installation Radiant FiresHave YOU Purged the GAS Supply Pipes Installation Convector FiresArrangement of Fuelbed Components AR1122 AR1119 Lighting Commissioning CommissioningServicing Requirements Fault FindingServicing Requirements Ignition Functional Check No Spark Fault FindingIgnition Lead Replacing PartsPiezo GAS Valve ODS Pilot UnitMain Injector MAG UnitChanging Between GAS Types Spares Parts Lists Spares Parts ListManual Fires Service Records Member of the Stovax Group

VFC Radiant & Convector Fire Range specifications

The Stovax VFC Radiant & Convector Fire Range embodies the pinnacle of contemporary fireplace design, marrying aesthetics with cutting-edge technology. This range is meticulously crafted to deliver warmth and style to any living space, ensuring an inviting atmosphere for families and guests alike.

One of the standout features of the VFC range is its dual-mode operation. The Radiant fires radiate heat directly into the room, creating immediate warmth, while the Convector models utilize advanced convection technology to circulate heated air throughout the space. This dual functionality allows homeowners to choose their preferred heating method, ensuring comfort during cold weather.

Energy efficiency is a cornerstone of the VFC range, designed with modern living in mind. The VFC fireplaces boast impressive efficiency ratings, meaning they convert a greater proportion of wood fuel into usable heat. This not only reduces fuel consumption but also minimizes emissions, making it a more environmentally friendly choice compared to traditional stoves.

Built from high-quality materials, the VFC range showcases a robust steel body paired with a cast iron door, ensuring durability and longevity. The range is also available in various sizes and styles, accommodating different room dimensions and personal tastes. Each model can be customized with a selection of trims and finishes that seamlessly integrate with a variety of interior decors.

The technology behind the VFC also includes a user-friendly air control system, enabling precise regulation of the burn rate. This feature contributes to optimal fuel efficiency and ensures a clean, environmentally friendly burn. Additionally, the large glass viewing window not only enhances the aesthetic appeal but also allows for a captivating view of the flames, adding to the ambiance of your room.

Moreover, installation is straightforward with the VFC range, which is designed to be compatible with existing flues and chimneys. Homeowners can enjoy a hassle-free setup while still benefiting from the advanced heating technologies.

In summary, the Stovax VFC Radiant & Convector Fire Range offers a compelling combination of modern technology, efficiency, and elegance. Its versatile heating options, environmentally-friendly design, and customizability make it an ideal choice for anyone looking to enhance their home’s comfort and style. Whether you’re curling up with a book or entertaining friends, the VFC range promises to create a warm and inviting centerpiece for your living space.