Stovax VFC Radiant & Convector Fire Range MAG Unit, Main Injector, Changing Between GAS Types

Page 21

INSTALLATION INSTRUCTIONS

REPLACING PARTS

6.5Disconnect the ignition lead from the gas valve, refer to section 27.

6.6Undo the two bolts securing the gas valve to the appliance and remove the valve.

6.7Replace in reverse order.

6.8Check all joints for gas leaks, check operation of the thermocouple and ignition lead.

8.MAG UNIT

7.1Carry out operations (a) to (d), section 4.

7.2Undo the mag unit retaining nut at the back of the control valve. See diagram 11 arrow A.

11

AR0945

7.3After removing the retaining nut, the mag unit can be tapped out and a replacement fitted.

7.4Replace the mag unit retaining nut and tighten. Note - this is a gas-tight seal.

7.5Replace the thermocouple and check for gas leaks.

7.6After reassembly, carry out the flame failure functional check as detailed in the flow chart, especially the mag unit drop out time.

9.MAIN INJECTOR

8.1Carry out operations (a) to (d), section 4.

8.2With the fire removed, undo the injector compression

nut (see diagram 6 arrow C), pull the pipe clear of the injector body.

6

8.3Rotate the injector until it is fully removed.

8.4Replace with the correct replacement injector. When ordering, always state the model, gas type and serial number.

8.5Reassemble and turn the gas supply on, check for any leaks

10. CHANGING BETWEEN GAS TYPES

The following parts must be changed when converting an appliance from one gas type to another:

Main injector

Pilot assembly

Aeration adjuster

Control valve

Data Badge

Refer to Gazco for a Conversion Kit

Note: The control valve will be set for the particular Appliance. In addition a new databadge will need to be ordered. In all instances, when ordering new parts, be sure to quote the appliance type and serial number.

Use only genuine Gazco replacement parts. Non-standard components will invalidate the guarantee and may be dangerous.

AR0945

21

Image 21
Contents VFC Radiant & Convector Fire Range Contents Appliance Commissioning Checklist Flue Check Pass FailGAS Check General User InstructionsLighting the Fire Turning the Fire OFFUpgrading Your Fire Cleaning the FireArrangement of Fuel BED Components Gazco Part NumberCoal Layout Oxygen Depletion Sensor Installation DetailsFlame Failure Device 10.’RUNNING IN’MIN Flue Specification Technical SpecificationCAT Minimum Flue SizeInstallation of the GAS Supply Installation InstructionsSite Requirements Flue and Chimney RequirementsInstallation Instructions Control Upgrade InstallationSafety Precautions Installation Radiant FiresHave YOU Purged the GAS Supply Pipes Installation Convector FiresArrangement of Fuelbed Components AR1122 AR1119 Lighting Commissioning CommissioningFault Finding Servicing RequirementsServicing Requirements Ignition Functional Check No Spark Fault FindingReplacing Parts Ignition LeadPiezo GAS Valve ODS Pilot UnitMAG Unit Main InjectorChanging Between GAS Types Spares Parts List Spares Parts ListsManual Fires Service Records Member of the Stovax Group

VFC Radiant & Convector Fire Range specifications

The Stovax VFC Radiant & Convector Fire Range embodies the pinnacle of contemporary fireplace design, marrying aesthetics with cutting-edge technology. This range is meticulously crafted to deliver warmth and style to any living space, ensuring an inviting atmosphere for families and guests alike.

One of the standout features of the VFC range is its dual-mode operation. The Radiant fires radiate heat directly into the room, creating immediate warmth, while the Convector models utilize advanced convection technology to circulate heated air throughout the space. This dual functionality allows homeowners to choose their preferred heating method, ensuring comfort during cold weather.

Energy efficiency is a cornerstone of the VFC range, designed with modern living in mind. The VFC fireplaces boast impressive efficiency ratings, meaning they convert a greater proportion of wood fuel into usable heat. This not only reduces fuel consumption but also minimizes emissions, making it a more environmentally friendly choice compared to traditional stoves.

Built from high-quality materials, the VFC range showcases a robust steel body paired with a cast iron door, ensuring durability and longevity. The range is also available in various sizes and styles, accommodating different room dimensions and personal tastes. Each model can be customized with a selection of trims and finishes that seamlessly integrate with a variety of interior decors.

The technology behind the VFC also includes a user-friendly air control system, enabling precise regulation of the burn rate. This feature contributes to optimal fuel efficiency and ensures a clean, environmentally friendly burn. Additionally, the large glass viewing window not only enhances the aesthetic appeal but also allows for a captivating view of the flames, adding to the ambiance of your room.

Moreover, installation is straightforward with the VFC range, which is designed to be compatible with existing flues and chimneys. Homeowners can enjoy a hassle-free setup while still benefiting from the advanced heating technologies.

In summary, the Stovax VFC Radiant & Convector Fire Range offers a compelling combination of modern technology, efficiency, and elegance. Its versatile heating options, environmentally-friendly design, and customizability make it an ideal choice for anyone looking to enhance their home’s comfort and style. Whether you’re curling up with a book or entertaining friends, the VFC range promises to create a warm and inviting centerpiece for your living space.