NEC RIH-6867 user manual Protection, Protective device will work at following cases

Page 15

Protection

Operating condition

The protective device maybe trip and stop the appliance in the cases listed below.

HEATING

Outdoor air temperature is over 24oc

Outdoor air temperature is below -7oc

 

Room temperature is over 27oc

COOLING

Outdoor air temperature is over *50oc

Room temperature is below 21oc

 

DRY

Room temperature is below 18oc

*For Tropical (T3) Climate condition models, the temperature point is 52instead of 43.

If the air conditioner runs in COOLING or DRY mode with door or window opened for a long time when relative humidity is above 80%,dew may drip down from the outlet.

Noise pollution

Install the air conditioner at a place that can bear its weight in order to operate more quietly.

Install the outdoor unit at a place where the air discharged and the operation noise would not annoy your neighbors.

Do not place any obstacles in front of the air outlet of the outdoor unit lest it increases the noise level.

Features of protector

The protective device will work at following cases.

Restarting the unit at once after operation stops or changing mode during operation, you need to wait 3 minutes.

Connect to power supply and turn on the unit at once, it may start 20 seconds later.

If all operation has stopped, press ON/OFFbutton again to restart, Timer should be set again if it has been canceled.

Features of HEATING mode

Preheat

At the beginning of HEATING operation, the airflow from indoor unit is discharged 2-5 minutes later.

Defrost

In HEATING operation the appliance will defrost (de-ice) automatically to raise efficiency. This procedure usually lasts 2-10 minutes. During defrosting, fans stop operation.

After defrosting completes, it returns to HEATING mode automatically.

Note: Heating is NOT available for cooling only air conditioner models.

13

PDF created with pdfFactory Pro trial version www.pdffactory.com

Image 15
Contents Inverter Split room air conditioner Use and Care Manual Preparation before use Auto Restart PresettingSafety precautions Indoor unit Outdoor unit Identification of partsCompressor indicator Temperature display Sleep Indicator UH series operating and Display Timer IndicatorRemote controller Remote controllerIndication symbols on LCD Choose Cooling Only Remote controller or Heat Pump How to Insert the BatteriesStorage and Tips for Using the Remote Controller How to UseOperation modes Operation instructionsAirflow direction control Airflow direction controlSmart mode Your feeling Button Adjustment procedure Slightly warmerSlightly cooler Timer-setting Timer modeSuper mode Sleep modeClose the front panel again MaintenanceCut off the power supply Clean and reinstall the air filterProtective device will work at following cases ProtectionTrouble Analysis TroubleshootingInstallation diagram Installation instructionsLocation for Installing Outdoor Unit Location for Installing Indoor UnitDrill a Hole for Piping Indoor unit installationInstalling the Mounting Plate Indoor Unit Piping InstallationPiping Thermal Insulation Piping ConnectionModel Pipe size Torque Nut width Min.thickness Outdoor Unit Connecting of the Cable Indoor UnitIndoor unit Outdoor unit installation Air purgingVacuum pump How to Purge Air Tubes ABN 86 001 217

RIH-6867 specifications

The NEC RIH-6867 is a cutting-edge, high-performance server designed to meet the demands of modern data centers. Its robust architecture and advanced technologies make it suitable for a wide range of applications, from cloud computing to enterprise resource planning.

One of the standout features of the RIH-6867 is its impressive processing power. The server is powered by the latest generation of Intel Xeon processors, allowing it to handle multiple workloads simultaneously. This multi-core architecture enhances performance in virtualized environments, ensuring that businesses can run resource-intensive applications without encountering bottlenecks.

Memory capacity is another key aspect of the RIH-6867. The server supports large volumes of RAM, enabling it to perform high-speed data processing and rapid information retrieval. This capability is particularly beneficial in scenarios that require real-time data analytics and high throughput. Additionally, the use of error-correcting code (ECC) memory ensures data integrity and reliability, which are crucial for mission-critical applications.

The NEC RIH-6867 also excels in storage options. It offers various configurations, including support for both HDD and SSD drives. This flexibility allows organizations to choose the storage solution that best fits their needs, balancing speed and capacity. Furthermore, integrated RAID support enhances data protection, providing redundancy and improving fault tolerance.

Networking capabilities are robust in the RIH-6867. The server features multiple Ethernet ports, supporting high-speed networking for seamless data transfers. This ensures that the server can efficiently communicate with other devices within the data center, contributing to overall operational efficiency.

Power efficiency is a significant consideration in the design of the RIH-6867. The server is equipped with advanced power management technologies that optimize energy consumption, which can lead to reduced operational costs over time. This aspect is particularly appealing for organizations focused on sustainability and minimizing their carbon footprint.

In addition, the NEC RIH-6867 is designed with maintainability in mind. Hot-swappable components and modular design facilitate easy upgrades and repairs, minimizing downtime and keeping maintenance costs low.

In summary, the NEC RIH-6867 integrates high-performance processing, extensive memory capacity, flexible storage solutions, and efficient networking capabilities. Its focus on energy efficiency and maintainability positions it as a premier choice for enterprises looking to enhance their IT infrastructure.