Westinghouse ES, ETL Safety tips, Observe the Following Read and Save These Instructions

Page 3

ETL-ES-Alloy-WH10

Safety tips

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT",

AND USE THE OUTLET SCREWS PROVIDED WITH THE OUTLET BOX. MOST OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURES

ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED. CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT.

1.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFPA 70-1999), including fire-rated construction.

2.Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.

3.After making the wire connections, gently push connections into outlet box with wire nuts pointing up. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

4.Before you begin installing the fan, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

5.Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

6.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

7.Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.

8.To reduce the risk of fire, electric shock, or personal injury, this fan must be mounted to an outlet box marked suitable for fan support, and use the mounting screws provided with the outlet box. (Mounting must support at least 35 lbs.)

9.WARNING! Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.

10.Attach the mounting bracket using only the hardware supplied with the outlet box. Fan is only to be mounted to an outlet box marked“Acceptable for Fan Support”.

11.WARNING! To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

12.If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

13.NEVER place a switch where it can be reached from a tub or shower.

14.The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

15.Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

16.All set screws must be checked and re-tightened where necessary before installation.

 

TOOLS REQUIRED

 

 

Phillips Screwdriver

Wire Cutters

Pliers

Step Ladder

3

Image 3
Contents Manual del usuario ETL-ES-Alloy-WH10 Observe the Following Read and Save These Instructions Safety tipsHaga LO Siguiente LEA Y Guarde Estas Instrucciones Consejos de seguridadFeatures Características COMBO-BLADEAspas DE Doble Cara PREPARING for installation Antes de la instalación ETL-ES-Alloy-WH10 Choose a Mounting Option Elija una Opción DE Montaje Mounting Options Opciones DE MontajeOpción CON Varilla Vertical Para Cielorraso Normal Normal Downrod OptionLoosen downrod ball 1 from downrod 2 by removing set screw ETL-ES-Alloy-WH10 Blade Installation Instalación de las paletas Mounting Montaje Opción DE Cableado Wiring OptionsAsegure el ventilador al cielorraso Secure To CeilingInstall light bulbs Instale las bombillas de luz ETL-ES-Alloy-WH10 Operation Operation and MaintenanceOperación Operación y mantenimientoTrouble Suggested Remedy Troubleshooting guideProblema Guía para solucionar problemasETL-ES-Alloy-WH10 ETL-ES-Alloy-WH10 Westinghouse Lighting Corporation

ES, ETL specifications

Westinghouse Electric Corporation has long been a name synonymous with innovation and technology in the energy sector. Among its various offerings, the Westinghouse ES and ETL (Energy Solutions and Energy Technology Line) stand out as pivotal elements designed to meet the ever-evolving demands of power generation and distribution.

The Westinghouse ES series focuses on enhancing energy efficiency and reliability. These systems are engineered to support both traditional and renewable energy sources, catering to the diverse needs of modern power grids. A significant feature of the ES line is its adaptability, allowing utilities to incorporate advanced analytics and IoT (Internet of Things) technologies. This adaptability ensures that power operators can optimize their energy resources, improve grid resilience, and enhance overall system performance.

On the other hand, the ETL series showcases Westinghouse's commitment to sustainability and enhanced environmental stewardship. The ETL systems are built with cutting-edge materials and technologies, which contribute to lower emissions and higher energy efficiency. One notable aspect of the ETL line is the integration of smart technology that facilitates real-time monitoring and control, ensuring that energy distribution is optimized and that operational costs are minimized.

Both the ES and ETL series utilize advanced automation and controls, allowing for seamless integration into existing infrastructures. These systems employ predictive maintenance capabilities, analyzing data trends to foresee potential issues before they develop into costly failures. This proactive approach not only maximizes uptime but also extends the life cycle of the equipment.

The Westinghouse ES and ETL systems are characterized by user-friendly interfaces, ensuring that operators can efficiently manage operations with ease. Their modular architecture allows for scalability, making it possible for energy providers to expand their capabilities as demands grow.

Furthermore, Westinghouse's commitment to safety is reflected in the design of both series, which adhere to the highest industry standards. Rigorous testing and quality assurance processes ensure that these systems are reliable and perform optimally under various conditions.

In conclusion, the Westinghouse ES and ETL series exemplify resilience, efficiency, and technological advancement in the energy sector. With their innovative features and commitment to sustainability, these systems are positioned to play a crucial role in the future of energy production and distribution. Whether tackling the challenges of a power grid or promoting greener energy solutions, Westinghouse continues to lead the way in energy technology innovation.