Westinghouse 78020, 78024 Safety Tips, Observe the Following Read and Save These Instructions

Page 2

UL-ES-5CC52-WH04(rev 1)

SAFETY TIPS

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY, MOUNT TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT",

AND USE THE OUTLET SCREWS PROVIDED WITH THE OUTLET BOX. MOST OUTLET BOXES COMMONLY USED FOR THE SUPPORT OF LIGHTING FIXTURES

ARE NOT ACCEPTABLE FOR FAN SUPPORT AND MAY NEED TO BE REPLACED. CONSULT A QUALIFIED ELECTRICIAN IF IN DOUBT.

1.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFPA 70-1996), including fire-rated construction.

2.Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.

3.After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

4.Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

5.Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

6.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

7.Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.

8.To reduce the risk of fire, electric shock, or personal injury, this fan must be mounted to an outlet box marked suitable for fan support. And use mounting screws provided with the outlet box. (Mounting must support at least 35 lbs.)

9.Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.

10.Attach the mounting bracket using only the hardware supplied with the outlet box. Fan is only to be mounted to an outlet box marked “Acceptable for Fan Support”.

11.To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

12.If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

13.NEVER place a switch where it can be reached from a tub or shower.

14.The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

15.Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

 

TOOLS REQUIRED

 

 

Phillips Screwdriver

Wire Cutters

Pliers

Step Ladder

2

Image 2
Contents Manual DEL Usuario Safety Tips Observe the Following Read and Save These InstructionsConsejos DE Seguridad Haga LO Siguiente LEA Y Guarde Estas InstruccionesFeatures Características Aspas DE Doble Cara COMBO-BLADECOMBO-MOTOR Motor DualPreparing for Installation Antes DE LA Instalación Instalación CON Soporte DE Montaje Mounting Options Opciones DE MontajeFlush Mount Option Opción DE Instalación AL RAS Save for later useOpción CON Varilla Vertical MÁS Larga Normal Downrod OptionPara Cielorraso Normal Slide downrod ball 1 off of downrod and remove pin UL-ES-5CC52-WH04rev Mounting Montaje Wiring Options Opción DE Cableado Wall Control Wiring OptionSecure to Ceiling Blade Installation Instalación DE LAS Paletas UL-ES-5CC52-WH04rev UL-ES-5CC52-WH04rev Operation and Maintenance OperationOperación Y Mantenimiento OperaciónTrouble Suggested RemedyGuía Para Solucionar Problemas ProblemaOr call 1-888-STAR-YES1-888-782-7937 Parts List Lista DE Repuestos UL-ES-5CC52-WH04rev
Related manuals
Manual 24 pages 48.3 Kb

78019, 78022, 78571, 78025, 78572 specifications

Westinghouse has long been synonymous with innovation and quality in the realm of electrical products. Among its numerous offerings, the Westinghouse models 78022, 78020, 78572, 78570, and 78021 stand out for their advanced technologies, reliability, and user-friendly features.

The Westinghouse 78022 is known for its superior durability and efficiency, featuring a robust construction that ensures longevity. It comes equipped with advanced thermal overload protection, which safeguards the motor from overheating, thus extending its lifespan. Its versatile design makes it suitable for various applications, whether in residential or commercial settings.

The 78020 model is celebrated for its compact design and high power-to-size ratio, making it an excellent choice for users seeking maximum performance in limited spaces. It also incorporates a multi-speed option, providing adaptability for different requirements. With its energy-efficient motor, the 78020 reduces electricity consumption without compromising output, making it an environmentally friendly option.

Model 78572 features a premium, full-metal housing that provides exceptional protection against external elements, ensuring consistent performance even in harsh environments. It boasts a noise-dampening design, making it quieter than many competitors, which is particularly advantageous in noise-sensitive areas. The 78572 also integrates advanced airflow technology, enhancing cooling efficiency and improving overall operation.

The Westinghouse 78570 is a high-capacity option designed for industrial applications. It includes features such as a heavy-duty construction and reinforced components that can handle continuous operation. The model is equipped with intelligent control systems that offer real-time monitoring of performance metrics, allowing for timely maintenance and operational efficiency.

Finally, the 78021 model is engineered for ease of use, featuring a simple interface that allows even novice users to operate it effectively. With built-in safety features such as automatic shut-off and surge protection, it prioritizes user safety. Additionally, the 78021's lightweight design enhances portability, making it ideal for job sites or temporary installations.

In summary, the Westinghouse models 78022, 78020, 78572, 78570, and 78021 collectively showcase the brand's commitment to quality, efficiency, and user satisfaction. Through a combination of robust construction, innovative technology, and user-friendly features, these models serve a diverse range of applications without compromising on performance or safety.