Westinghouse MA7200-4001/2-N1 Quick Start Guide for Pump Applications, Apply Power to the Drive

Page 2

MA7200 PLUS Inverter 1 to 2 HP Pump Quick Start Manual

_______________________________________________________________

Quick Start Guide for Pump Applications

This guide is to simplify the start up of the MA7200 PLUS Inverter series, 1 to 2 HP, for pump applications. It is not intended to replace the MA7200 PLUS Installation and Operation Manual, and the user is urged review this manual. There are three methods of control or combinations thereof that that may be selected; Keypad, Analog Signal (external terminal), or Serial Communication. Only Keypad and analog signal control will be covered as serial communication is beyond the scope of this manual. For serial communication control or special external control, the user is referred to the MA7200 PLUS Installation and Operating Manual.

SAFETY FIRST!

Step 1 - Before Starting the Inverter

Referring to the MA7200 PLUS Instruction Manual, please review and verify that the correct inverter size for the associated motor was received free of damage. To ensure personnel safety and to avoid equipment damage, follow the precautions and the installation procedures for mounting, wiring, and operating environment.

CAUTION - To avoid damage to the inverter when removing the inverter cover and/or LCD Operator, refer to Appendix B for the proper procedure.

In accordance with applicable codes, make electrical connections to the motor and input power terminals. (Refer to the block diagram, Fig. 4). No other external connections should be made at this time, as the initial control will be from the keypad.

Step 2 - Apply Power to the Drive

Apply AC power to the Inverter and observe the LCD Display Line 1; it should read

Freq. Cmd 000.00Hz”. Line 2 should read “TECO”. The red LED on the STOP key should be on. The DRIVE and FWD LED’s should be on. (See Fig. 1 below)

LED ON

DRIVE FWD

REV

REMOTE

 

 

 

 

 

SEQ

REF

 

LED ON

Freq. Cmd 000.00Hz

 

 

 

TECO

 

 

 

 

 

FLASHING

 

DIGITAL OPERATOR JNEP-36

 

 

PRGM

 

DSPL

 

 

DRIVE

 

 

 

 

 

 

 

LOCAL

 

EDIT

 

 

REMOTE

 

ENTER

 

 

FWD

 

 

 

 

REV

 

RESET

LED ON

 

 

 

 

RUN

 

STOP

 

Fig. 1 MA7200 PLUS Keypad

Step 3 - Set Drive to Run Mode

If the red DRIVE LED is not on with AC power up, press the PGRM / DRIVE key until the red Drive LED is on. The Inverter is now in the RUN mode.

______________________________________________________________ 2

TECO – Westinghouse Motor Company

Image 2
Contents MA7200 Plus Inverter Quick Start Guide for Pump Applications Apply Power to the DriveSet Drive to Run Mode Before Starting the InverterCheck Pump Motor Operation Select Method of Control Sn 04= Sn 05=MA7200 Plus Inverter 1 to 2 HP Pump Quick Start Manual MA7200 Plus Inverter 1 to 2 HP Pump Quick Start Manual Digital Input / Output terminal connections 1 2 HP Analog Input terminal connections 1 2 HP MA7200 Plus Block Diagram Appendix a MA7200 Plus Inverter 1 to 2 HP Pump Quick Start Manual