INTRODUCTION

GENERAL

Gas fired broilers are designed for commercial use only and feature fast, efficient gas heat. Each burner is controlled by an adjustable on/off gas valve.

Model

Number

BTU/hr Input

 

of Burners

Rating

 

 

 

VST4B

3 @ 45,000 ea.

135,000

 

 

 

UNPACKING

Immediately after unpacking, check for possible shipping damage. If the broiler is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.

INSTALLATION

Before installing, verify that the type of gas (natural or propane) and the clearance dimensions (see below) agree with the specifications on the rating plate which is located on right hand side of unit.

Location

The installation location must be kept free and clear of combustibles. Do not obstruct the flow of combustion and ventilation air.

Clearances

Check that there are sufficient clearances to service the broiler and to make the required gas supply connection(s). Provide 24" clearance at the front for cleaning, maintenance, service and proper operation.

Combustible

Non-Combustible

Construction

Construction

 

 

 

 

Sides

Rear

Sides

Rear

 

 

 

 

6 inches

6 inches

0 inches

0 inches

INSTALLATION CODES

AND STANDARDS

The broiler must be installed in accordance with the following:

In the United States of America:

1.State and local codes.

2.National Fuel Gas Code, ANSI-Z223.1/ NFPA #54 (latest edition). Copies may be obtained from The American Gas Association Accredited Standards Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001, or the Secretary Standards Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-7471.

3.NFPA Standard #96 Vapor Removal from Cooking Equipment, latest edition, available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

4.In the Commonwealth of Massachusetts all gas appliances vented through a ventilation hood or exhaust system equipped with a damper or with a power means of exhaust shall comply with 248 CMR.

In Canada:

1.Local codes.

2.CAN/CSA-B149.1 Natural Gas Installation (latest edition).

3.CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3.

— 4 —

Image 4
Contents Installation Chop House Broilers Important for Your Safety For Your SafetyTable of Contents Installation Installation Codes StandardsIntroduction GeneralBroiler Stand Installation LEG Stand Assembly InstructionsRequired Tools CASTER-EQUIPPED Broilers Griddle Plate InstallationBurners & Ceramic Bricks Ventilation Hood GAS Pressure Regulator InstallationGAS Connection Operation ControlsLighting the GAS Pilot Temporary ShutdownPreheating the Broiler AdjustmentsGriddle Cleaning Broiler GrateGrease Chutes GriddleService and Parts Information MaintenanceVent System 35684 UNIS-ÉTATS AUX Imprimé Entretien VentilationInoxydable acier en Surfaces Frire à PlaqueNettoyage RéglagesFrire À Plaque Grilloir DU PréchauffageCommandes FonctionnementComplet Arrêt Temporaire ArrêtGAZ DE Pression DE Régulateur D’UN Installation GAZ DU Branchement Ventilation DE HotteCéramique EN Briques ET Brûleurs NivelageRequis Outils Pattes DE Support DU AssemblageFig patte la de ’assemblage de extrémité petite la dans Déballage Normes ET D’INSTALLATION CodesGénéralités Matières DES Table Sécurité DE Mesure AvertissementImportantes Sécurité DE Mesures GAZ AU Grilloirs