Westinghouse 62204 owner manual Mounting and Wiring Instructions, Fixture Assembly Instructions

Page 4

MOUNTING AND WIRING INSTRUCTIONS

NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures meet all UL specifications.

1.Turn off power at circuit box to avoid possible electric shock.

2.Secure mounting bar (A) to outlet box (B) with outlet box screws (C) (not included) (see fig. 1).

3.Thread hex nut (D) onto nipple 1 (E1) approximately 1/4 inch and insert lockwasher (F), then thread nipple 1 (E1) onto mounting bar (A) and secure with hex nut (D).

4.Thread nipple 2 (G2) onto base (H) (carefully twist loop (I) to secure nipple 2 (G2) if needed). Do not twist or kinkwires.

5.Slide column (J) down over nipple 2 (G2).

6.Open one link on bottom end of chain (K). Attach to loop (I). Securely close link on chain (K).

7.Thread screw collar ring (L) onto screw collar (M), then place canopy (N) over top of screw collar (M).

8.Lace wires up through every other link on chain (K) then through screw collar (M) and nipple 1 (E1).

9.Open one link on top end of chain (K). Attach to loop on screw collar (M). Securely close link on chain (K).

10.Identify color coding of fixture wires (see fig. 2).

11.To connect wires, take black fixture wire (group A from fig. 3) and place evenly against black outlet box wire. Do not twist wires.

12.Fit wire connector (O from fig. 1) over wires and twist until there is a firm connection. If wire connector (O) easily comes off, reattach and check again for a firm connection.

13.Repeat steps 11 and 12 with the white (group B from fig. 3) fixture wires and outlet box wires.

14.Partially thread green grounding screw (P) into side hole (Q) on mounting bar (A)

15.Wrap ground wire from fixture around green grounding screw (P), leaving enough excess wire to then connect ground wire and outlet box wire with wire connector.

16.Tighten green grounding screw (P). Do not over tighten.

17.Tuckwires inside outlet box (B).

18.Remove screw collar ring (L) from screw collar (M).

19.Secure screw collar (M) to nipple 1 (E1).

20.Raise canopy (N) to ceiling and thread screw collar ring (L) to screw collar (M) and tighten as necessary.

FIXTURE ASSEMBLY INSTRUCTIONS

Warning: This fixture is for indoor use only.

1.Install lamp(s). Do not exceed recommended wattage.

2.Place glass shade(s) (R) into holder(s) (S) and secure with thumb screws (T) or retaining ring(s) (U), whichever is applicable. Do not over tighten.

3.Turn power back on at circuit box.

4

Image 4
Contents Indoor Lighting Fixture Installation Instructions Assembly Instructions for Indoor Light Fixture Warranty InformationGround Mounting and Wiring Instructions Fixture Assembly InstructionsGarantie Limitée DE Cinq ANS Les instructions d’installation demeurent cependant valables Instructions DE Montage ET DE Raccordement Instructions D’ASSEMBLAGE DE Lappareil DéclairageGarantía Limitada DE Cinco Años Advertencia UNA Descarga Eléctrica Podría Causar LesionesFigura Instrucciones DE Montaje Y Cableado Instrucciones DE Montaje DEL ArtefactoFigura Cleaning and Care Commande DE PiècesOrdering Parts Nettoyage ET Entretien