| NOTE: CEILING COVER, | |
OUTLET | SUPPLY WIRES AND FAN | |
WIRES OMITTED FOR | ||
BOX | ||
CLARITY. | ||
|
| HANGER | |
| BRACKET | |
Figure 8 | HANGER BALL/ | |
DOWNROD ASSEMBLY | ||
|
How to Wire Your Ceiling Fan
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
!WARNING
To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, as it must be grounded for safe operation.
1.Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation).
!WARNING
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.
3.Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket.
4.Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 10).
5.Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs (supplied). (Figure 10). Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod. Your fan is now wired to be turned on and off from the fan switch.
CEILING COVER
LOCKWASHERS (2) THREADED STUD
KNURLED KNOB
Figure 10
GROUND WIRE
BLACK AND BLUE FAN WIRES
NOTE: CEILING COVER OMITTED FOR CLARITY.
!WARNING
To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the
WIRE CONNECTORS (3)
GREEN WIRE (GROUND)
FROM FAN
Figure 9
WHITE SUPPLY (NEUTRAL)
WHITE FAN
WIRE
BLACK SUPPLY (HOT)
ceiling.
6.Cut the
NOTE: If you are using an Emerson light fixture with your fan, remove the three screws securing the switch housing cover to the switch housing and remove the cover. Remove the screw plug from the bottom of the switch housing cover and install the light in accordance with the light kit Owner's Manual.
2.Connect the fan motor white wire to the supply white (neutral) wire using a wire connector (supplied) (Figure 7). Connect the fan motor black wire and blue wire to the supply black (hot) wire using a wire connector (supplied) (Figure 7). Your fan is now wired to be turned on and off from the fan switch. After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box.
6
Using Your Ceiling Fan
!WARNING
To reduce the risk of fire or electrical shock, do not use this fan with any
1.Restore electrical power to the outlet box by turning the electricity on at the main fuse box.
2.Check the operation of the fan by gently pulling on the pull chain switch.
3.All fans are shipped from the factory with the reversing switch positioned to circulate air downward. If airflow is desired in opposite direction,
U.L. Model No.: CF652