Hunter Fan 41081-01 installation manual Installing the Hanger Bracket

Page 5

2 • Installing the Hanger Bracket

2-1. Drill two pilot holes into the wood support structure through the outermost holes in the outlet box, using the ceiling plate as a guide. The pilot holes should be 9/64” in diameter.

2-2. Install one canopy screw into each side of the ceiling plate as shown.

2-3. Place a flat washer on each of the two 3” wood screws.

2-4. Thread the lead wires from the outlet box down through the hole in the middle of the ceiling plate.

2-5. Align the slotted holes in the ceiling plate with the pilot holes you drilled in the wood support structure.

2-6. Pass the wood screws through the slotted holes in the hanger bracket into the pilot holes you drilled.

Tighten the wood screws into the 9/64” pilot holes; do not use lubricants on the screws. Do not over tighten.

Canopy Screw

Step 2-1

Step 2-2

Flat Washer

3” Wood Screw

5

41081-01 • 08/04/09 • Hunter Fan Company

Image 5
Contents Type 2 Models Welcome Mounting and Optional Accessories Getting Ready Installing Multiple Fans?Installing the Hanger Bracket Holes in the top of the fan Assembling and Hanging the FanGo to 4 Wiring the Fan Dual Switch Wiring Wiring the FanSingle Switch Wiring Installing the Canopy Installing the Light Fixture To Change Airflow Direction Operating and Cleaning Your Ceiling FanTroubleshooting