Distributed by | | Personal Ultrasonic |
| |
| | | | ® | Humidifier |
| | | | |
| | | | |
| | | | | | ke A Mo | m | e | |
| | | | | a | |
| | | | T | | | |
| | | | e | | | | n | |
| | | | | | | t |
| | | s | | | | | N |
| | a | | | | | | o |
| e | | | | | | | w |
P | l | | | Register | |
| | | |
Your Product At:
www.homedics.com/register
Your valuable input regarding this
product will help us create
the products you will
want in the future.
HUM-CM10
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
2.NOTE: For first time use and with each new wick, you must soak the wick before operating.
Unlock the spring loaded wick by turning to the wick holder to the left. Remove the wick from the wick holder and soak the wick in water for 2 minutes. Replace the wick into the wick holder and secure to the humidifier top cover by turning to the right.
CAUTION: DO NOT operate the humidifier without first soaking the wick. The humidifier WILL NOT function without a wick.
3.Fill the water tank with clean, cool (not cold) tap water to the MAX FILL line. DO NOT OVERFILL. We recommend using distilled water if you live in a hard water area.
4.Replace the humidifier top cover by turning
clockwise until tight.
Surface Cleaning
Clean the surface of the unit with a clean damp soft cloth.
Troubleshooting
PROBLEM | POSSIBLE CAUSE | SOLUTION |
| | |
Power Light | • Unit is not plugged in | • Plug unit in |
is off | • No power at outlet or | • Push POWER button to turn the |
| USB port | power on |
| • Computer may be in | • Check circuits, fuses, try a |
| Sleep Mode | different outlet or USB port |
| | • Open Computer, activate out of |
| | Sleep Mode |
| | |
Peculiar | • If new unit | • Open the water reservoir and |
Odor | • If unit is in use, the odor | keep it in a shady and cool |
| may be a dirty water | place for 12 hours |
| reservoir, old tank water | • Empty the old water, clean the |
| or an old wick | reservoir and fill with clean |
Instruction Manual and
Warranty Information
IMPORTANT SAFETY INSTRUCTIONS
WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE PRESENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE USING
WARNING—TO REDUCE THE RISK OF BURNS,FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS:
•Always place humidifier on a firm, flat, level surface. A waterproof mat or pad is recommended for use under the humidifier. Never place it on a rug or carpet, or on a finished floor that may be damaged by exposure to water or moisture.
•Always unplug the appliance from the electrical outlet immediately after using and before cleaning.
•DO NOT reach for an appliance that has fallen into water. Unplug it immediately.
•DO NOT use water above 86º Fahrenheit.
•An appliance should never be left unattended when plugged in.
•Use this appliance only for its intended use as described in this manual. Do not use attachments not recommended by HoMedics; specifically any attachments not provided with the unit.
•NEVER operate this appliance if it has a damaged cord or plug, if it is not working properly, if it has been dropped, or dropped into water.
•Do not place the humidifier near heat sources, such as a stove and do not expose the humidifier to the direct sunlight.
•Never cover the appliance when it is in operation.
•Do not touch the water in the main unit or the parts in the water when the unit is on.
•Perform regular maintenance of the Ultrasonic Nebulizer.
•Never use detergent to clean the ultrasonic nebulizer that is not recommended by the manufacturer.
•Never scrape the ultrasonic nebulizer with a hard object to clean.
•Do not repair or adjust the unit. Servicing must be performed by professional or qualified personnel.
•Stop use if there is an unusual noise or smell. Servicing should be performed by qualified personnel only.
•Never operate unit without water in the tank. Only use water in the tank.
•Never add any additive to the water that is not produced or under the supervision of the manufacturer.
•Keep the appliance out of reach from children. Do not allow children to use the appliance without supervision.
•This appliance is designed for personal, non-professional use only.
•For indoor use only.
Unique Features and Specifications
Ultrasonic Technology
This humidifier uses ultrasonic high frequency technology to convert the water into 1–5 million super particles that are dispersed into the air evenly. These particles then combine with the ions generated by the humidifier to moisten the air.
120V AC and USB Adaptors Included
Perfect for use at Home, in the Office, or On-The Go
Ultrasonic Nebulizer
The humidifier utilizes special spray techniques and the ultrasonic nebulizer is easy to clean.
Voltage | Tank Capacity |
5V DC | 200mL – 7/8 Cup |
How to Use
Power ON/OFF | Mist Spout |
|
Button | |
Water Reservoir | | Spring Loaded | |
Fig. 1 | Wick | Fig. 2 |
CAUTION: This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature. To do so could result in an electric shock hazard.
Power ON/OFF Button
Plug unit in to either a 120 volt AC electrical outlet or USB Port. Push the POWER Button once to turn unit on. Push again to turn the unit off.
How to Fill
CAUTION: Before filling unit with water, turn power off and unplug unit from the outlet.
1. Unscrew the humidifier top cover from the water reservoir by turning the top cover counter- clockwise.
Lift the top cover off and set aside.
Fig. 3
Fig. 6
5. To turn on, press the ON/OFF button on the Top Cover. The LED light will illuminate when the humidifier is ON.
NOTE: This humidifier does not include an Auto | |
Shut-off when the unit runs out of water. The unit | |
MUST be unplugged when not in use or when the | |
water runs out. | Fig. 7 |
|
How to Change Wick
1.Remove replacement wick from package and soak in water for 2 minutes.
2.Unlock the spring loaded wick by turning the wick holder to the left and removing from the top cover. (Fig 4)
3.Remove the old wick from the wick holder and discard.
4.Place the new, soaked wick into the wick holder.
5.Place the wick holder back on the unit and lock into place by turning the holder to the right.
NOTE: To order additional replacement wicks, please visit www.homedics.com or HoMedics Consumer Relations at 1.800.466.3342
Cleaning and Care
CAUTION: Before cleaning the unit, turn power off and unplug unit from the outlet.
Tank Cleaning
Unscrew the humidifier top cover from the water reservoir by turning the top cover counter- clockwise. Lift the top cover off and set aside Wipe the reservoir with a soft cloth then rinse it with clean water. Suggestion: Clean the water tank once every two to three weeks, depending on your water conditions.
Ultrasonic Nebulizer Cleaning
To clean the ultrasonic nebulizer, you must first remove the spring loaded wick. To remove the wick, turn the top humidifier cover over. Turn the spring loaded wick holder to the left. Remove the spring loaded wick and set aside.
Make a solution of mild dish soap and water. Dip a soft bristle brush into the solution and brush ultrasonic nebulizer. Wipe clean with a soft cloth.
NOTE: DO NOT pour water into the ultrasonic nebulizer or submerge unit in water.
| | water |
| | • Replace with a new wick |
| | |
Excessive | • Unit is not level | • Place unit on a flat, even surface |
Noise | • Low water level | • Check the water level. Refill the |
| • Wick was not soaked | reservoir if the water is low |
| | • Remove wick, soak for 2 |
| | minutes and replace wick |
LIMITED ONE YEAR WARRANTY
HoMedics sells its products with the intent that they are free of defects in manufacture and workmanship for a period of one year from the date of original purchase, except as noted below. HoMedics warrants that its products will be free of defects in material and workmanship under normal use and service. This warranty extends only to consumers and does not extend to Retailers.
To obtain warranty service on your HoMedics product, mail the product and your dated sales receipt (as proof of purchase), postpaid, to the following address:
HoMedics Service Center Dept. 168, Suite 3
43155 West Nine Mile Rd Novi, MI 48375
No COD’s will be accepted.
HoMedics does not authorize anyone, including, but not limited to, Retailers, the subsequent consumer purchaser of the product from a Retailer or remote purchasers, to obligate HoMedics in any way beyond the terms set forth herein. This warranty does not cover damage caused by misuse or abuse; accident; the attachment of any unauthorized accessory; alteration to the product; improper installation; unauthorized repairs or modifications; improper use of electrical/power supply; loss of power; dropped product; malfunction or damage of an operating part from failure to provide manufacturer’s recommended maintenance; transportation damage; theft; neglect; vandalism; or environmental conditions; loss of use during the period the product is at a repair facility or otherwise awaiting parts or repair; or any other conditions whatsoever that are beyond the control of HoMedics.
This warranty is effective only if the product is purchased and operated in the country in which the product is purchased. A product that requires modifications or adoption to enable it to operate in any other country than the country for which it was designed, manufactured, approved and/or authorized, or repair of products damaged by these modifications is not covered under this warranty.
THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY. THERE SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FiTNESS OR ANY OTHER OBLIGATION ON THE PART OF THE COMPANY WITH RESPECT TO PRODUCTS COVERED BY THIS WARRANTY. HOMEDICS SHALL HAVE NO LIABILITY FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES. IN NO EVENT SHALL THIS WARRANTY REQUIRE MORE THAN THE REPAIR OR REPLACEMENT OF ANY PART OR PARTS WHICH
ARE FOUND TO BE DEFECTIVE WITHIN THE EFFECTIVE PERIOD OF THE WARRANTY. NO REFUNDS WILL BE GIVEN. IF REPLACEMENT PARTS FOR DEFECTIVE MATERIALS ARE NOT AVAILABLE, HOMEDICS RESERVES THE RIGHT TO MAKE PRODUCT SUBSTITUTIONS IN LIEU OF REPAIR OR REPLACEMENT.
This warranty does not extend to the purchase of opened, used, repaired, repackaged and/or resealed products, including but not limited to sale of such products on Internet auction sites and/or sales of such products by surplus or bulk resellers. Any and all warranties or guarantees shall immediately cease and terminate as to any products or parts thereof which are repaired, replaced, altered, or modified, without the prior express and written consent of HoMedics.
This warranty provides you with specific legal rights. You may have additional rights which may vary from country to country. Because of individual country regulations, some of the above limitations and exclusions may not apply to you.
For more information regarding our product line in the USA, please visit: www.homedics.com
©2011 HoMedics, Inc. and its affiliated companies, all rights reserved. HoMedics® is a registered trademark of HoMedics, Inc. and its affiliated companies. All rights reserved.
IB-HUMCM10
Mail To: | |
HoMedics Service Center | |
Dept. 168, Suite 3 | |
43155 West Nine Mile Rd | |
Novi, MI 48375 | E-mail: cservice@homedics.com |