Lightolier LSBW-2 manual 1BHFPG, Performance Distribution is Symmetrical, Accessories

Page 2

Lighting Systems LSBW-2

1BHFPG

-ZUFTQSFBEÜ-4#4PMJE8BMM.PVOU-JHIU51FS'PPU /PNJOBM 4FDUJPO

Performance Distribution is Symmetrical

Candlepower Curve

Candlepower Summary

180

170

160

ZONE

0

22

45

67

90

 

 

 

 

 

 

 

 

 

DEG.

 

 

 

 

 

 

 

150

 

 

CANDELAS

 

 

 

 

 

 

 

 

 

 

 

140

 

 

 

 

 

 

 

130

180

738

738

738

738

738

 

 

 

175

736

743

753

772

771

 

 

120

165

707

768

833

914

923

 

 

 

 

 

 

 

 

 

 

11

155

652

779

914

1081

1120

 

 

0

 

 

 

 

 

 

 

 

 

145

567

772

991

1246

1313

 

 

100

135

454

728

1038

1433

1541

 

 

 

125

354

690

1165

1685

1715

 

 

90

115

227

649

1211

1357

1361

 

 

 

 

 

 

 

 

 

 

80

105

119

590

746

792

793

425

 

95

34

162

117

118

93

 

 

 

 

70

90

14

24

15

15

15

 

 

85

0

0

0

0

0

850

 

 

 

60

75

0

0

0

0

0

 

 

1275

 

50

65

0

0

0

0

0

 

55

0

0

0

0

0

 

 

 

 

40

45

0

0

0

0

0

 

 

30

1700

 

35

0

0

0

0

0

20

20

0

 

25

0

0

0

0

0

 

 

Report No:

LRL3001E

15

0

0

0

0

0

5

0

0

0

0

0

Cat No:

LSB24A28

0

0

0

0

0

0

Lamps:

 

2-F28T5

 

Calculations are for 28 watt T5 lamps. For 54 watt T5 lamps, multiply by 1.7.

Lumens:

2900

Efficiency:

86.1%

 

 

 

 

 

 

COEFFICIENTS OF UTILIZATION

 

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

 

 

80

 

 

 

70

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

 

 

70

50

30

 

70

50

30

 

50

30

10

 

 

 

 

 

0

 

82

82

82

 

70

70

70

 

48

48

48

1

 

75

71

68

 

64

61

58

 

42

40

39

2

 

68

62

57

 

58

53

49

 

36

34

32

3

 

62

54

49

 

53

47

42

 

32

29

27

4

 

56

48

42

 

48

41

36

 

28

25

23

5

 

51

42

36

 

44

36

31

 

25

22

19

6

 

47

38

31

 

40

32

27

 

22

19

16

7

 

43

34

27

 

37

29

27

 

20

17

14

8

 

40

30

24

 

34

26

21

 

18

15

12

9

 

37

27

21

 

31

24

19

 

16

13

11

10

 

34

25

19

 

29

21

17

 

15

12

10

 

 

 

 

20% FLOOR CAVITY REFLECTANCE

 

 

 

 

 

 

 

 

DISTRIBUTION

 

 

 

 

Zone

 

Lumens

 

 

% Lamp

 

 

% Luminaire

0-90

 

0

 

 

 

0.0

 

 

 

0.0

 

90-180

4995

 

 

 

86.1

 

100.0

 

0-180

 

4995

 

 

 

86.1

 

100.0

 

Fixture Lengths & Mounting Locations

 

53-1/4"

 

 

 

(135.26cm) (OAL)

 

3.5"

4-Foot

40"(101.60cm)

 

 

(8.89cm)

 

101-1/4" (257.18cm) (OAL)

 

 

8-Foot

80" (203.20cm)

 

 

 

 

 

 

149-1/4" (379.10cm) (OAL)

90°

12-Foot

80" (203.20cm)

40"(101.60cm)

4-Foot Run

 

 

8-Foot Run

 

 

 

 

 

 

12-Foot Run

 

 

197-1/4" (501.02) (OAL)

16-Foot Run

16-Foot

80" (203.20cm)

80" (203.20cm)

20-Foot Run

 

 

24-Foot Run

 

 

 

 

 

245-1/4" (622.94cm) (OAL)

40"(101.60cm)

20-Foot

80" (203.20cm)

80" (203.20cm)

 

 

 

4-Foot

Module

1

1

1

8-Foot

Module

1

1

2

2

3

LSBWE

1

1

1

1

1

1

80" (203.20cm)

293-1/4" (744.86cm) (OAL)

80" (203.20cm)

80" (203.20cm)

24-Foot

 

 

Accessories

 

 

End Set :

LSBWEWH: White

 

 

LSBWEAL: Aluminum

 

Order one per run of fixtures.

 

Job Information

Type:

"JSQPSU3PBE'BMM3JWFS."t  t'BY  

We reserve the right to change details of design, materials and finish.

XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #

Image 2
Contents 1BHFPG Performance Distribution is Symmetrical Accessories1BHFPG Fixture Lengths & Mounting Locations