Lightolier IS:406 instruction sheet Instruction Sheet for 6.5 Pendalyte, Glass Shade Installation

Page 1

INSTRUCTION SHEET FOR 6.5” PENDALYTE™

Note: This instruction sheet covers several luminaire styles. Powerhead assembly, lamp type, and reflector style may vary slightly from that shown, although installation is the same.

120/277V

NEUTRAL

GREEN (OUTLET BOX PLATE GROUND)

 

GREEN

 

GREEN

GREEN

WIRE

NUTS

BALLAST

OUTLET BOX

SCREWS

RELIEF

BUSHING

CANOPY

OUTLET BOX PLATE

KNOT

CANOPY

BRACKET

CORD

BLACK

WHITE

 

RE D

RED/WHITE

 

 

 

 

 

 

 

BALLAST

RED

RED

 

 

 

 

CORD

CANOPY SCREWS

 

 

 

 

 

 

 

 

BLUE

BLUE

 

 

 

 

BLUE

BLUE/WHITE

 

Fig. 1

 

WIRE DIAGRAM

 

CAUTION: MAXIMUM WATTAGE AS MARKED

CORD

 

GLASS SHADE INSTALLATION (fig.3)

ON LUMINAIRE MUST NOT BE EXCEEDED.

 

 

 

 

 

1.

Insert RETAINER CUP through top

 

 

 

HINGE

RELIEF

 

of glass SHADE.

 

 

THREADED INSERTS

BUSHING

2.

Place O-RING over RETAINER

 

 

MARK

 

 

 

 

 

CUP.

 

 

 

 

 

 

 

 

 

 

 

3.

Align RETAINER CUP with

 

RETAINER CUP

 

 

 

 

THREADED INSERTS in socket

 

 

 

 

 

 

plate.

 

 

GASKET STRIP

 

 

 

 

 

 

 

CANOPY

 

 

REFLECTOR

ADHESIVE BACKING

 

BRACKET

 

 

 

Fig. 2

 

 

 

 

 

 

THREADED INSERTS

 

 

8-32 SCREWS

 

 

 

 

 

Fig. 4

 

RETAINER CUP

 

 

 

 

 

 

 

 

 

 

O-RING

SHADE

ALUMINUM REFLECTOR INSTALLATION (Fig. 4)

1.Peel ADHESIVE BACKING off of 3 GASKET STRIPS. Apply GASKET STRIPS, equally spaced, to lip of RETAINER CUP.

2.Insert RETAINER CUP through top of REFLECTOR and align with THREADED INSERTS in socket plate.

3.Secure with 8-32 screws.

8-32 SCREWS

Fig. 3

Image 1