Lightolier C4T4VW specifications Candlepower Distribution, Angle, Wall RCR

Page 2

Calculite® HID Downlight C4T4VW

Page 2 of 2

4 1/2” Aperture, 2pc Vertical, T4.5 Wide Beam

20W T4, GE CMH LAMP, LUMEN RATING = 1700 LMS, AROMAT 20W ELECTRONIC BALLAST, CL FINISH TRIM

CANDLEPOWER DISTRIBUTION

250

500

750

1,000

 

ANGLE

MEAN CP LUMENS

 

0

1162

 

 

5

1128

107

 

10

1055

 

 

15

961

270

 

20

832

 

60°

25

691

326

30

600

 

 

 

 

35

512

307

 

40

331

 

 

45

124

115

 

50

11

 

 

55

2

4

 

60

1

 

 

65

0

0

 

70

0

 

 

75

0

0

 

80

0

 

 

85

0

0

30°

90

0

 

 

 

 

LUMINANCE SUMMARY CD. / SQ. M.

 

 

 

 

 

 

Coefficients of Utilization

 

 

 

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

17204

 

CEILING

 

 

80%

 

70%

 

50%

 

30%

 

 

 

 

 

 

 

 

 

 

 

55

 

370

 

 

 

 

 

 

 

 

 

 

 

WALL

70

50

30

10

50

10

50

10

50

10

0

 

65

 

13

 

 

 

75

 

0

 

 

 

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

85

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

.79

.79

.79

.79

.77

.77

.74

.74

.71

.71

.67

 

 

 

 

 

 

 

 

 

 

 

 

1

.76

.74

.73

.72

.73

.70

.70

.68

.68

.66

.63

 

 

 

 

 

 

 

2

.73

.70

.68

.66

.69

.65

.67

.63

.65

.62

.60

 

ZONAL LUMENS AND PERCENTAGES

 

3

.69

.66

.63

.60

.65

.60

.63

.59

.62

.58

.56

 

 

4

.66

.62

.59

.56

.61

.56

.60

.55

.59

.55

.53

 

ZONE LUMENS

% LAMP %LUMINAIRE

 

 

 

5

.63

.58

.55

.52

.58

.52

.56

.52

.55

.51

.50

 

0-30

702

41.33

62.26

 

 

0-40

1009

59.4

89.5

 

6

.60

.55

.51

.49

.55

.49

.54

.48

.53

.48

.47

 

0-60

1128

66.36

99.98

 

7

.57

.52

.48

.46

.51

.45

.50

.45

.50

.45

.44

 

0-90

1128

66.37

100

 

8

.55

.48

.45

.42

.48

.42

.47

.42

.47

.42

.41

 

40-90

118

6.97

10.5

 

9

.52

.46

.42

.39

.45

.39

.44

.39

.44

.39

.38

 

60-90

0

0.02

0.02

 

10

.49

.43

.39

.36

.42

.36

.42

.36

.41

.36

.35

 

90-180

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-180

1128

66.37

100

 

LUMINAIRE INPUT WATTS = 23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** EFFICIENCY = 66.4% ** SC = .9

CERTIFIED TEST REPORT NO. 2318FR, DATE: SEP 28, 2003 COMPUTED BY LSI PROGRAM **TEST-LITE**

39W T4 , PHILIPS CMH LAMP, LUMEN RATING = 3300 LMS, AROMAT 39W ELECTRONIC BALLAST, CL FINISH TRIM

CANDLEPOWER DISTRIBUTION

375

750

1,125

1,500

 

ANGLE

MEAN CP LUMENS

 

0

1725

 

 

5

1679

160

 

10

1602

 

 

15

1542

436

 

20

1464

 

60°

25

1371

641

30

1332

 

 

 

 

35

1104

659

 

40

655

 

 

45

242

225

 

50

24

 

 

55

5

8

 

60

2

 

 

65

0

1

 

70

0

 

 

75

0

0

 

80

0

 

 

85

0

0

30°

90

0

 

 

 

 

LUMINANCE SUMMARY CD. / SQ. M.

 

 

 

 

 

 

Coefficients of Utilization

 

 

 

 

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

33540

 

CEIILING

 

 

 

80%

 

 

70%

 

50%

 

30%

 

 

 

 

 

 

 

 

 

 

 

 

55

 

928

 

 

 

 

 

 

 

 

 

 

 

 

WALL

70

50

30

10

50

10

50

10

50

10

0

 

65

 

78

 

 

 

75

 

0

 

 

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

85

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

.77

.77

.77

.77

.75

.75

.72

.72

.69

.69

.65

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

.74

.72

.71

.69

.71

.68

.68

.66

.66

.64

.61

 

 

 

 

 

 

2

 

.70

.68

.65

.63

.66

.62

.64

.61

.63

.60

.58

 

ZONAL LUMENS AND PERCENTAGES

3

 

.67

.63

.60

.58

.62

.58

.61

.57

.59

.56

.54

 

4

 

.64

.59

.56

.54

.59

.53

.57

.53

.56

.52

.51

 

ZONE LUMENS

% LAMP %LUMINAIRE

 

 

5

 

.61

.56

.52

.49

.55

.49

.54

.49

.53

.48

.47

 

0-30

1236

37.46

58.06

 

 

0-40

1895

57.42

88.99

6

 

.58

.52

.49

.46

.52

.46

.51

.46

.50

.45

.44

 

0-60

2128

64.51

99.97

7

 

.55

.49

.45

.43

.48

.42

.48

.42

.47

.42

.41

 

0-90

2129

64.53

100

8

 

.52

.46

.42

.39

.45

.39

.44

.39

.44

.39

.38

 

40-90

234

7.1

11.01

9

 

.49

.42

.39

.36

.42

.36

.41

.36

.41

.36

.35

 

60-90

0

0.02

0.03

10

 

.46

.40

.36

.33

.39

.33

.39

.33

.38

.33

.32

 

90-180

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0-180

2129

64.53

100

LUMINAIRE INPUT WATTS = 44

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

** EFFICIENCY = 64.5% ** SC = 1.1

CERTIFIED TEST REPORT NO. 2317FR, DATE: SEP 27, 2003 COMPUTED BY LSI PROGRAM **TEST-LITE**

70W T4, PHILIPS CMH LAMP, LUMEN RATING = 6400 LMS, AROMAT 70W ELECTRONIC BALLAST, CL FINISH TRIM

CANDLEPOWER DISTRIBUTION

750

1,500

2,250

3,000

** EFFICIENCY = 61.6% ** SC = 1.1

 

ANGLE

MEAN CP

LUMEN

 

 

 

 

 

 

 

 

 

Coefficients of Utilization

 

 

 

 

 

0

3202

296

LUMINANCE SUMMARY CD. / SQ. M.

 

 

 

 

 

 

 

 

 

 

 

5

3121

ANGLE

MEAN CD/SQ M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

2971

 

45

 

61531

 

CEILING

 

 

80%

 

 

70%

 

50%

 

30%

 

 

 

15

2858

810

55

 

806

 

 

 

 

 

 

 

 

 

 

20

2741

 

65

 

0

 

 

WALL

70

50

30

10

50

10

50

10

50

10

0

 

 

25

2618

1208

 

 

 

 

60°

75

 

0

 

 

 

RCR

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

 

30

2467

 

 

 

 

 

 

 

 

85

 

0

 

 

 

 

 

35

2000

1206

 

 

 

 

 

0

.74

.74

.74

.74

.72

.72

.69

.69

.66

.66

.62

 

 

40

1210

 

 

 

 

 

 

1

.71

.69

.68

.66

.68

.65

.65

.63

.63

.61

.58

 

 

45

445

414

 

 

 

 

 

 

2

.67

.65

.63

.60

.64

.60

.62

.59

.60

.57

.55

 

 

 

 

 

 

 

 

 

 

50

39

11

ZONAL LUMENS AND PERCENTAGES

 

3

.64

.61

.58

.56

.60

.55

.58

.54

.57

.53

.52

 

 

55

5

ZONE LUMENS

% LAMP %LUMINAIRE

 

4

.61

.57

.54

.51

.56

.51

.55

.51

.54

.50

.49

 

 

60

0

 

0-30

2314

36.16

58.67

 

5

.58

.53

.50

.47

.53

.47

.52

.47

.51

.46

.45

 

 

65

0

0

0-40

3520

55

89.23

 

6

.55

.50

.47

.44

.50

.44

.49

.44

.48

.43

.42

 

 

70

0

 

0-60

3944

61.64

100

 

7

.52

.47

.43

.41

.47

.41

.46

.41

.45

.40

.39

 

 

75

0

0

0-90

3944

61.64

100

 

8

.50

.44

.40

.38

.43

.38

.43

.37

.42

.37

.36

 

 

80

0

 

40-90

424

6.64

10.77

 

9

.47

.41

.37

.35

.40

.35

.40

.34

.39

.34

.33

 

 

0

60-90

0

0

0

 

 

 

85

0

90-180

0

0

0

 

10

.44

.38

.34

.32

.38

.32

.37

.32

.37

.32

.31

 

30°

90

0

 

0-180

3944

61.64

100

 

LUMINAIRE INPUT WATTS = 78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CERTIFIED TEST REPORT NO. 2316FR, DATE: SEP 27, 2003

COMPUTED BY LSI PROGRAM **TEST-LITE**

Job Information

 

Type:

Lightolier a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504

Image 2
Contents Frame-In Kit Lamp FeaturesOptions and Accessories ElectricalWall RCR Candlepower DistributionAngle Wall