| Lytespan® Track Lighting System 83W7U |
Page of 2 | PowerArc™ Modular |
Lighting Data |
|
| |
Footcandles on wall: |
|
8 |
53 f.c. |
36 f.c. |
53 f.c. |
EXAMPLE: With track located 4’ from wall and multiple units spaced 8’ on center and aimed 50˚ from horizontal, the illumination on wall 4’ from ceiling will be 53 f.c. beneath units and 36 f.c. between units.
Lamp Information:
70W
CRI: 82
Rated Avg. life: 10,000 hrs. For 100W Multiply by 1.5.
Footcandles on Wall
Track 3 Feet From Wall |
|
| Single Unit |
|
| |||
|
| 3’ | 0’ | 1’ | 2’ | 3’ | 4’ | 5’ |
|
|
|
|
|
|
|
| |
|
|
|
| Beam Center |
|
|
| |
Ceiling | 1' |
| 132 | 111 | 62 | 27 | 11 | 6 |
2 | 50˚ | 118 | 115 | 71 | 35 | 14 | 6 | |
3' |
| 91 | 88 | 59 | 32 | 14 | 7 | |
From |
| |||||||
4' |
| 57 | 53 | 40 | 27 | 14 | 7 | |
Distance |
| |||||||
5' |
| 35 | 33 | 26 | 19 | 13 | 7 | |
6' |
| 22 | 21 | 17 | 14 | 11 | 7 | |
7' |
| 15 | 14 | 12 | 10 | 8 | 7 | |
|
| |||||||
| 8' |
| 11 | 10 | 9 | 8 | 7 | 6 |
| 9' |
| 8 | 8 | 7 | 6 | 5 | 5 |
Track 4 Feet From Wall |
|
| Single Unit |
|
| |||
|
| 4’ | 0’ | 1’ | 2’ | 3’ | 4’ | 5’ |
|
|
|
| Beam Center |
|
|
| |
Ceiling | 1' |
| 70 | 63 | 44 | 26 | 13 | 6 |
2' | 50˚ | 69 | 68 | 51 | 33 | 18 | 8 | |
3' |
| 61 | 63 | 51 | 33 | 19 | 9 | |
From |
| |||||||
4' |
| 50 | 50 | 42 | 29 | 18 | 9 | |
Distance |
| |||||||
5' |
| 35 | 34 | 29 | 22 | 16 | 9 | |
6' |
| 24 | 23 | 20 | 16 | 13 | 9 | |
7 |
| 17 | 16 | 14 | 11 | 9 | 7 | |
|
| |||||||
| 8' |
| 12 | 11 | 10 | 8 | 7 | 6 |
| 9' |
| 8 | 8 | 8 | 6 | 5 | 5 |
| 10' |
| 6 | 6 | 6 | 5 | 4 | 4 |
| 11' |
| 5 | 5 | 4 | 4 | 3 | 3 |
| 12' |
| 3 | 3 | 3 | 3 | 3 | 2 |
4’
156 | 133 | 156 |
149 | 150 | 148 |
122 | 128 | 121 |
89 | 90 | 88 |
66 | 61 | 65 |
48 | 45 | 47 |
36 | 35 | 35 |
28 | 28 | 27 |
23 | 24 | 22 |
6’*
77 | 53 | 77 |
77 | 67 | 77 |
71 | 66 | 71 |
59 | 59 | 59 |
45 | 46 | 45 |
35 | 33 | 35 |
27 | 24 | 27 |
21 | 18 | 21 |
16 | 14 | 16 |
12 | 11 | 12 |
10 | 9 | 10 |
8 | 7 | 8 |
Multiple Units
5’
14594 145
132112 133
10698 107
73 | 74 | 74 |
52 | 51 | 53 |
39 | 37 | 40 |
30 | 29 | 31 |
24 | 23 | 24 |
20 | 20 | 20 |
Multiple Units
8’*
73 | 26 | 73 |
| |||
72 | 36 | 72 |
| |||
64 | 38 | 64 |
| |||
|
|
|
|
|
| |
| 53 |
| 36 |
| 53 |
|
39 | 32 | 39 |
| |||
28 | 26 | 28 |
| |||
20 | 19 | 20 |
| |||
16 | 15 | 16 |
| |||
12 | 11 | 12 |
| |||
10 | 9 | 10 |
| |||
8 | 7 | 8 |
| |||
6 | 6 | 6 |
|
6’
13652 136
12168 121
95 | 63 | 95 |
62 | 54 | 62 |
40 | 38 | 40 |
28 | 27 | 28 |
20 | 19 | 21 |
15 | 15 | 16 |
12 | 11 | 12 |
10’*
71 | 12 | 71 |
70 | 17 | 70 |
63 | 19 | 63 |
51 | 18 | 51 |
37 | 19 | 37 |
26 | 18 | 26 |
19 | 15 | 19 |
13 | 12 | 13 |
10 | 10 | 10 |
8 | 8 | 8 |
6 | 6 | 6 |
5 | 5 | 5 |
|
|
|
Footcandles are average and rounded off and data for multiple units are based on a minimum of five units.
For 100W: Multiply values by 1.5 Rated Lamp Life 12,500 Hrs.
Job Information | Type: |
|
|
Lightolier a Genlyte company | www.lightolier.com |
631 Airport Road, Fall River, MA 02720 • (508)
© 2006 Genlyte Group LLC • D1106