Deepcel Plus DPA2G16LS26U
Page 2 of 2
Photometry | Model No. DPA2G16LS26U120SO |
G00030
DPA2G16LS26U120SO
2 T* U6, EACH RATED 2750 LUMENS.
2X2 TROFFER WITH 4X4 16 CELL LI SEMISPECULAR LOUVER.
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
2' x 2' Recessed Fluorescent, 3", 16 Cell Parabolic Louver Static or Air/Return, 2 Lamp 6"U T8
LER = FP - 49.4 | IW - 57.5 | BF - 0.87 | | | | | | | | | | | |
Comparative yearly lighting energy cost per 1000 lumens = $4.86 | | | | | |
| coefficients of utilization — zonal cavity method | | | | | | | | | | |
| | RF | | | | 20 | | | | | 20 | | | | | | | 20 | |
| | RC | | | | 80 | | | | | 50 | | | | | | | 30 | |
| | RW | | 70 | | 50 | | 30 | | 50 | 30 | | 10 | | | 50 | 30 | 10 |
| | 1 | | 69 | | 66 | | 64 | | 63 | 61 | | 60 | | | 60 | 59 | 58 |
| ratio | 2 | | 64 | | 60 | | 56 | | 57 | 54 | | 52 | | | 55 | 52 | 51 |
| 3 | | 59 | | 54 | | 50 | | 51 | 48 | | 45 | | | 49 | 47 | 44 |
| cavity | 4 | | 55 | | 48 | | 44 | | 46 | 42 | | 40 | | | 45 | 42 | 39 |
| 5 | | 51 | | 44 | | 39 | | 42 | 38 | | 35 | | | 41 | 37 | 35 |
| room | 6 | | 47 | | 40 | | 35 | | 38 | 34 | | 31 | | | 37 | 34 | 31 |
| 7 | | 44 | | 36 | | 31 | | 35 | 31 | | 28 | | | 34 | 30 | 28 |
| | 8 | | 41 | | 33 | | 29 | | 32 | 28 | | 25 | | | 31 | 28 | 25 |
| | 9 | | 38 | | 31 | | 26 | | 30 | 26 | | 23 | | | 29 | 25 | 23 |
| | 10 | | 36 | | 28 | | 24 | | 28 | 24 | | 21 | | | 27 | 23 | 21 |
| visual comfort probability (VCP) average 100 fc; reflectances 80/50/20 | | | | | |
| | room size | | | | | ceiling height | | | | | | | ceiling height | | |
| W | | | L | | 8.5 | 10.0 | 13.0 | | 16.0 | | | | 8.5 | 10.0 | 13.0 | | 16.0 |
20 | | | 20 | | | 79 | 73 | 66 | | 70 | | | | 79 | 72 | 67 | | 72 |
20 | | | 30 | | | 82 | 75 | 70 | | 66 | | | | 81 | 75 | 69 | | 65 |
20 | | | 40 | | | 84 | 78 | 73 | | 69 | | | | 83 | 77 | 73 | | 68 |
| 20 | | | 60 | | | 85 | 80 | 76 | | 72 | | | | 84 | 79 | 75 | | 71 |
30 | | | 20 | | | 83 | 77 | 69 | | 70 | | | | 83 | 77 | 69 | | 71 |
30 | | | 30 | | | 85 | 79 | 72 | | 66 | | | | 84 | 79 | 72 | | 66 |
30 | | | 40 | | | 86 | 81 | 75 | | 69 | | | | 86 | 81 | 74 | | 68 |
30 | | | 60 | | | 87 | 83 | 77 | | 72 | | | | 87 | 82 | 77 | | 71 |
| 30 | | | 80 | | lengthwise | 87 | 83 | 79 | | 74 | | crosswise | | 87 | 84 | 78 | | 73 |
40 | | | 40 | | 87 | 83 | 78 | | 71 | | | 87 | 83 | 77 | | 70 |
40 | | | 20 | | | 84 | 80 | 73 | | 71 | | | | 84 | 80 | 74 | | 72 |
40 | | | 30 | | luminaries | 86 | 81 | 76 | | 68 | | luminaries | | 86 | 81 | 75 | | 68 |
40 | | | 60 | | 88 | 84 | 80 | | 73 | | | 88 | 84 | 79 | | 72 |
40 | | | 80 | | | 88 | 84 | 81 | | 75 | | | | 88 | 85 | 81 | | 74 |
| 40 | | | 100 | | | 88 | 84 | 81 | | 77 | | | | 88 | 85 | 82 | | 76 |
60 | | | 30 | | | 87 | 82 | 77 | | 71 | | | | 86 | 82 | 77 | | 71 |
60 | | | 40 | | | 88 | 84 | 79 | | 73 | | | | 87 | 84 | 79 | | 73 |
60 | | | 60 | | | 89 | 85 | 81 | | 75 | | | | 88 | 85 | 81 | | 74 |
| | | | | | |
60 | | | 80 | | | 89 | 85 | 82 | | 77 | | | | 89 | 86 | 82 | | 76 |
| 60 | | | 100 | | | 89 | 86 | 83 | | 79 | | | | 89 | 86 | 83 | | 78 |
100 | | | 40 | | | 88 | 84 | 81 | | 75 | | | | 87 | 84 | 80 | | 74 |
100 | | | 60 | | | 89 | 85 | 82 | | 77 | | | | 88 | 85 | 81 | | 76 |
100 | | | 80 | | | 89 | 86 | 83 | | 79 | | | | 89 | 86 | 83 | | 78 |
| 100 | | | 100 | | | 89 | 86 | 84 | | 80 | | | | 89 | 86 | 84 | | 80 |
Ordering Information
Explanation of Catalog Number. Example: DPA2G16LS26U120SOCP
Deepcel Plus
Parabolic:
Pre-anodized
aluminum
louver
DP
DY
ND
| | | | | Number of | Louver Finish: | Single "V" |
Body Style: | | Fixture | Ceiling Type: |
A=Air Supply | | Width | G= Grid | Cells: | L = Low | Reflector |
S=Static | | | (lay-in T bar) | 16=4 rows | iridescence | |
| | |
| | | | F= Flanged (over | of 4 | Semi-specular | |
| | | | lap) Z spline and | | (standard) | |
| | | | plaster frame | | P =Low | |
| | | | T= Slot grid or | | iridescence | |
Standard Deepcel | | two-directional | | Specular | |
| concealed T | | W =White Baked | |
| | | | (see options) | | Enamel | |
For NYC Code – I.B.E.W. Manufactured
For NYC Code – Local 3 Manufactured 5½" Deep Body
Lamp | | | | | | | | |
| | | | | Options: |
Quantity | | | Voltage: | | Add appropriate |
| | | | | suffix to catalog no., |
| | | | 120, 277 or | | | ie: (CP) |
| | | UNV=120-277 | | | | | |
| Lamp | Type/ | | Ballast | Type: | | | |
| Fixture Length: | | | | <20THD <10THD |
| 6"U Lamp | | 1-2 Lamp Elec. T8 | SO * | H | * |
| T8 or T12 | | LOL T8 Dimming | PS | | I– |
| (Nominal 24") | | *Instant Start Standard | | | | |
| Note: For Linear | | | | | |
| | Other dimming options. Consult factory. |
| T5 Lamp option, | |
| consult factory | | NOTE: | | | | |
| | | | For T8 UNV, you must use HI Ballast Code. |
| | | |
Options/Accessories
Plaster Frame: Catalog Number: PF22.
Continuous Row Installation: For F type fixtures, half width flanges are required between
fixtures. Order Catalog Number: 2FC TRIM CSP (each joint).
Radio Interference Filter: To order one RIF per fixture; SUFFIX: R. To order one RIF per ballast;
SUFFIX: B.
Electrical Wiring Options: Consult factory.
Air Closure Strip: SUFFIX: ACS2 (factory installed).
Drywall Kit: Order Catalog Number: FK92X2. (Request Folio OA30-10 Rev. A).
Chicago Plenum: SUFFIX: CP.
Specifications (continued)
Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi- specular anodized vertical grain aliminum reflector sheet is standard.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is with- in 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W. UL and ULc Listed.
Specifications
Performance: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .66. To prevent glare the VCP shall be not less than 74 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 914 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 62.8%.
Air Handling (DPA only) side air pasaages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends.
Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal.
| Job Information | Type: | |
| |
Lightolier a Genlyte company | www.lightolier.com |
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.
© 2007 a Genlyte company | Section 2/Folio G51-36 Rev. A |