| HP90 Recessed Fluorescent H9S2GLR132 or 232 |
Page 2 of 2 | Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens |
| Static, 2 Lamp T8 |
Model No. H9S2GLR132UNVHI
LER = FP - 74.8 IW - 26.66 BF - 0.88 Comparative yearly lighting ene gy cost per
1000 lumens = $3.21
Report Number: G2007123
Catalog Number: H9S2GLR132UNVHI
Lamps: (1) F28 T8
Luminaire: HP90 2' x 4' with linear prismatic lens.
Ballast:
Report is based on 2725 Lumens per lamp. Efficiency: 80%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.4 | |||
Shielding Angles: |
|
| 90 |
|
| 90 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 46.800 |
| 22.800 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.20 |
| ||||||||
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
1 | 86 | 82 | 79 | 77 | 74 | 72 | 74 | 72 | 70 |
2 | 78 | 71 | 65 | 67 | 62 | 58 | 64 | 60 | 57 |
3 | 71 | 62 | 55 | 58 | 53 | 48 | 56 | 51 | 47 |
4 | 64 | 54 | 47 | 51 | 45 | 40 | 49 | 44 | 40 |
5 | 59 | 48 | 41 | 46 | 39 | 35 | 44 | 39 | 34 |
6 | 54 | 43 | 36 | 41 | 35 | 30 | 40 | 34 | 30 |
7 | 50 | 39 | 32 | 37 | 31 | 26 | 36 | 30 | 26 |
8 | 47 | 36 | 29 | 34 | 28 | 24 | 33 | 27 | 23 |
9 | 44 | 33 | 26 | 31 | 25 | 21 | 30 | 25 | 21 |
10 | 41 | 30 | 24 | 29 | 23 | 19 | 28 | 23 | 19 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. | |||
45 | 789. | 942. | 1069. |
55 | 718. | 973. | 1165. |
65 | 592. | 1025. | 1337. |
75 | 447. | 1159. | 1429. |
85 | 309. | 509. | 370. |
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 659 | 659 | 659 |
|
5 | 654 | 658 | 660 | 63 |
15 | 628 | 643 | 655 | 182 |
25 | 578 | 612 | 641 | 282 |
35 | 507 | 562 | 609 | 351 |
45 | 415 | 495 | 562 | 380 |
55 | 306 | 415 | 497 | 365 |
65 | 186 | 322 | 420 | 311 |
75 | 86 | 223 | 275 | 208 |
85 | 20 | 33 | 24 | 39 |
90 | 3 | 3 | 2 |
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
0- 30 | 526 | 19 3 | 24 1 |
0- 40 | 877 | 32 2 | 40 2 |
0- 60 | 1623 | 59 6 | 74.4 |
0- 90 | 2180 | 80 0 | 100 0 |
0 | 0 0 | 0 0 | |
2180 | 80 0 | 100 0 |
Model No. H9S2GLR232UNVHI
LER = FP - 73.6 IW - 55.1 BF - 0.88 Comparative yearly lighting ene gy cost per
1000 lumens = $3.26
Report Number: G2007007
Catalog Number: H9S2GLR232UNVHI
Lamps: (2) F28 T8
Luminaire: HP90 2' x 4' with linear prismatic lens.
Ballast:
Report is based on 2725 Lumens per lamp. Efficiency: 84.6%
CIE |
|
|
|
| |||||
Plane: |
|
|
|
|
| ||||
Spacing Criteria: |
|
| 1.2 |
|
| 1.4 | |||
Shielding Angles: |
|
| 90 |
|
| 90 | |||
Plane: |
|
|
|
|
| ||||
Luminous Length: |
| 46.800 |
| 22.800 | |||||
COEFFICIENTS OF UTILIZATION – |
|
| |||||||
ZONAL CAVITY METHOD. EFFECTIVE |
| ||||||||
FLOOR CAVITY REFLECTANCE 0.20 |
| ||||||||
|
|
|
|
|
|
|
|
|
|
RC |
| 80 |
|
| 50 |
|
| 30 |
|
RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 |
1 | 92 | 87 | 84 | 82 | 79 | 76 | 79 | 76 | 74 |
2 | 83 | 76 | 70 | 71 | 66 | 62 | 68 | 64 | 61 |
3 | 75 | 66 | 59 | 62 | 56 | 52 | 60 | 55 | 51 |
4 | 69 | 58 | 50 | 55 | 49 | 44 | 53 | 47 | 43 |
5 | 63 | 52 | 44 | 49 | 42 | 38 | 47 | 42 | 37 |
6 | 58 | 47 | 39 | 44 | 38 | 33 | 43 | 37 | 32 |
7 | 54 | 42 | 34 | 40 | 34 | 29 | 39 | 33 | 29 |
8 | 50 | 38 | 31 | 37 | 30 | 26 | 36 | 30 | 25 |
9 | 47 | 35 | 28 | 34 | 27 | 23 | 33 | 27 | 23 |
10 | 44 | 32 | 26 | 31 | 25 | 21 | 30 | 25 | 21 |
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE IN DEG.
45 1891. 2179. 2413.
55 1704. 2208. 2574.
65 1416. 2264. 2759.
75 1072. 2379. 2749.
85 666. 1050. 683.
CANDELA DISTRIBUTION
| 0.0 | 45.0 | 90.0 | FLUX |
0 | 1481 | 1481 | 1481 |
|
5 | 1471 | 1474 | 1478 | 140 |
15 | 1421 | 1429 | 1446 | 404 |
25 | 1298 | 1344 | 1398 | 620 |
35 | 1131 | 1219 | 1301 | 763 |
45 | 921 | 1061 | 1175 | 814 |
55 | 673 | 872 | 1006 | 767 |
65 | 412 | 659 | 803 | 629 |
75 | 191 | 424 | 490 | 394 |
85 | 40 | 63 | 41 | 77 |
90 | 3 | 3 | 3 |
|
ZONAL LUMEN SUMMARY
ZONE | LUMENS | % LAMP | % FIXT |
0- 30 | 1165 | 21.4 | 25 3 |
0- 40 | 1927 | 35.4 | 41 8 |
0- 60 | 3508 | 64.4 | 76 1 |
0- 90 | 4609 | 84 6 | 100 0 |
0 | 0 0 | 0 0 | |
4609 | 84 6 | 100 0 |
Ordering Information
Explanation of Catalog Number. Example: H9S2GLR232UNVHI
S
2
G
L
R
32
|
|
|
|
|
|
|
|
| Reflector: | Lamp |
HP90 | Body Style: | Fixture | Ceiling |
| Type: | Ac ylic Lens | ||||
| ||||||||||
Direct/Indi ect | S = Static | Width | Fits both |
| Specular | Quantity | ||||
Recessed |
|
| Standard Grid |
| Aluminum | 1=1 Lamp | ||||
|
|
|
| and |
|
| 2=2 Lamp | |||
|
|
|
| Slot Grid |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
H9 |
| Standard HP90 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
HY |
| For NYC Code – I B.E.W. Manufactured |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
HN |
| For NYC Code – Local 3 Manufactu ed |
|
|
|
|
|
|
|
Lamp:
(By Others) 32 =T8 32W* (Nominal 48")
* 28W T8 available
Voltage: |
|
|
| Options: |
120, 277 or |
|
| Add appropriate | |
|
| suffix to catalog | ||
|
|
|
| no., ie: (GLR) |
Ballast Type: |
| |||
|
| <20THD <10THD | ||
1 or 2 Lamp Elec. T8 | SO * | HI * | ||
LOL Dimming T8 | PS | – |
*Instant Start Standard
Other dimming options. Consult factory.
NOTE: For T8 UNV, you must use HI Ballast Code.
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF.
Drywall Kit: Order Catalog Number: FK92X4.
Electrical Wiring Options: Consult factory.
For motion or light sensor. See Folio
Specifications
Performance: In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .87. To reduce glare the average brightness at 65° shall not exceed 2759 candelas per square meter. To control veiling reflections, luminaire output in the
Materials: Chassis parts are
Lamp Shield: Linear prismatic translucent DR acrylic lens.
Finish: Chassis exterior – baked white polyester enamel. Cavity – baked white polyester enamel. Rust preventative undercoating. Reflector – low irides- cence specular aluminum 95% reflectance.
Specifications (continued)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations. |
|
Labels: I.B.E.W./UL and ULc Listed. |
|
This product may have a mercury containing lamp. Manage in accord with | |
Disposal Laws. See: www.lamprecycle.org | |
Job Information | Type: |
Lightolier a Genlyte company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
© 2007 a Genlyte company | Section 5/Folio |