| Test instrumentation | Model name | Manufacturer | 
| 
 | 
 | 
 | 
| Stopwatch | PC90 | Time Art | 
| 
 | 
 | 
 | 
| Power meter | WT1806 | Yokogawa | 
| 
 | 
 | 
 | 
| Power Source | 61605 | Chroma | 
| 
 | 
 | 
 | 
Serial or Firmware
(No./Ver.)
TPST003 0GAA-B04817  0GAA-B05037 
Calibration
Date
1st Apr. 2015
30th Mar. 2015
7th Oct. 2015
1.8Measurement method used
-Measurement condition_1) Picture : no input load, 2) Sound : no input load.
-Deactivate all other network ports that are not under test.
-Ensure that the EUT does not perform a main function and wait for 20 minutes, So that the EUT able to go into the networked mode.
-The EUT standby mode power consumption was monitored for a further period of 5 minutes.
The variation in power consumption over this period is ≤ 5%, so the maximum reading of NTW standby mode power as measured by the power analyzer is recorded as the test result
1.9
2. Off mode
2.1 Test result
| 
 | 
 | Test date | 
 | 
 | N/A | 
 | Power Consumption (W) | 
 | N/A | |||
| 
 | 
 | 
 | 
 | 
 | (rounded to the 1st decimal place) | 
 | ||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 2.2 Test parameters | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | parameters | 
 | Actual | Limit | parameters | 
 | Actual | Limit | 
 | ||
| 
 | 
 | Ambient temperature (℃) | 
 | - | 
 | Test voltage (V) | 
 | - | 
 | 
 | ||
| 
 | 
 | Test frequency (Hz) | 
 | - | 
 | Total harmonic distortion | 
 | - | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | (%) | 
 | 
 | 
 | 
 | 
| 
 | 
 | Crest factor | 
 | - | 
 | - | 
 | - | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
2.3Description of how the appliance mode was selected or programmed
N/A
3