Samsung AR18FSFPESNNEU, AR18FSFPESNXEU manual ErP InformationAC Product

Page 1

ErP Information(AC Product)

 

 

 

 

 

 

AR18FSFPESNN / AR18FSFPESNX

According to Commission Regulation (EU) No 206/2012

 

 

 

 

 

 

 

 

 

 

 

 

 

If function includes heating: Indicate the heating season the

 

Function (indicate if persent)

 

informaiont relates to. Indicated values should relate to one

 

 

heating season at a time. Include at least the heating season

 

 

 

 

 

 

 

 

 

 

 

 

 

 

'Average'

 

 

cooling

 

Y

 

Average

 

 

Y

heating

 

Y

 

Warmer

 

 

N

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Colder

 

 

N

 

 

 

 

 

 

(if designated)

 

 

 

 

 

 

 

 

 

 

 

 

Item

symbol

 

value

 

unit

Item

symbol

 

value

 

unit

Design load

 

 

 

 

 

Seasonal efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Pdesignc

 

5,0

 

kW

cooling

SEER

 

6,7

 

-

heating/Average

Pdesignh

 

4,5

 

kW

heating/Average

SCOP/A

 

3,8

 

-

heating/Warmer

Pdesignh

 

-

 

kW

heating/Warmer

SCOP/W

 

-

 

-

heating/Colder

Pdesignh

 

-

 

kW

heating/Colder

SCOP/C

 

-

 

-

Declared capacity(*) for

cooling, at indoor temperature

 

 

 

Declared energy efficiency ratio(*), at indoor temperature

 

 

27(19) ℃ and outdoor temperature Tj

 

 

 

27(19) ℃ and outdoor temperature Tj

 

 

 

 

Item

symbol

 

value

 

unit

Item

symbol

 

value

 

unit

Tj = 35 ℃

Pdc

 

5,0

 

kW

Tj = 35 ℃

EERd

 

3,0

 

-

Tj = 30 ℃

Pdc

 

3,7

 

kW

Tj = 30 ℃

EERd

 

4,9

 

-

Tj = 25 ℃

Pdc

 

2,4

 

kW

Tj = 25 ℃

EERd

 

7,9

 

-

Tj = 20 ℃

Pdc

 

1,8

 

kW

Tj = 20 ℃

EERd

 

14,2

 

-

Declared capacity(*) for

heating/Average season, at indoor

 

Declared coefficient of performance(*)/Average season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = - 7 ℃

Pdh

 

4,1

 

kW

Tj = -7

COPd

 

2,7

 

-

Tj = 2 ℃

Pdh

 

2,6

 

kW

Tj = 2 ℃

COPd

 

3,8

 

-

Tj = 7 ℃

Pdh

 

1,6

 

kW

Tj = 7 ℃

COPd

 

4,6

 

-

Tj = 12 ℃

Pdh

 

1,2

 

kW

Tj = 12 ℃

COPd

 

5,2

 

-

Tj = bivalent

Pdh

 

4,5

 

kW

Tj = bivalent

COPd

 

2,3

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

 

 

kW

Tj = operating limit

COPd

 

2,3

 

-

Declared capacity(*) for

heating/Warmer season, at indoor

 

Declared coefficient of performance(*)/Warmer season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = 2 ℃

Pdh

 

-

 

kW

Tj = 2 ℃

COPd

 

-

 

-

Tj = 7 ℃

Pdh

 

-

 

kW

Tj = 7 ℃

COPd

 

-

 

-

Tj = 12 ℃

Pdh

 

-

 

kW

Tj = 12 ℃

COPd

 

-

 

-

Tj = bivalent

Pdh

 

-

 

kW

Tj = bivalent

COPd

 

-

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

-

 

kW

Tj = operating limit

COPd

 

-

 

-

Declared capacity(*) for

heating/Colder season, at indoor

 

Declared coefficient of performance(*)/Colder season,

 

 

temperature 20 ℃ and outdoor temperature Tj

 

 

 

at indoor temperature 20 ℃ and outdoor temperature Tj

 

 

Tj = -7

Pdh

 

-

 

kW

Tj = -7

COPd

 

-

 

-

Tj = 2 ℃

Pdh

 

-

 

kW

Tj = 2 ℃

COPd

 

-

 

-

Tj = 7 ℃

Pdh

 

-

 

kW

Tj = 7 ℃

COPd

 

-

 

-

Tj = 12 ℃

Pdh

 

-

 

kW

Tj = 12 ℃

COPd

 

-

 

-

Tj = bivalent

Pdh

 

-

 

kW

Tj = bivalent

COPd

 

-

 

-

temperature

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

Tj = operating limit

Pdh

 

-

 

kW

Tj = operating limit

COPd

 

-

 

-

Tj = -15

Pdh

 

-

 

kW

Tj = -15

COPd

 

-

 

-

Bivalent temperature

 

 

 

 

 

Operating limit temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

heating/Average

Tbiv

 

-10

 

heating/Average

Tol

 

-10

 

heating/Warmer

Tbiv

 

-

 

heating/Warmer

Tol

 

-

 

heating/Colder

Tbiv

 

-

 

heating/Colder

Tol

 

-

 

Cycling interval capacity

 

 

 

Cycling interval efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

for cooling

Pcycc

 

-

 

kW

for cooling

EERcyc

 

-

 

-

for heating

Pcych

 

-

 

kW

for heating

COPcyc

 

-

 

-

Degradation

 

 

 

 

 

Degradation

 

 

 

 

 

co-efficient

Cdc

 

0,25

 

kW

co-efficient

Cdh

 

0,25

 

-

cooling(**)

 

 

 

 

 

heating(**)

 

 

 

 

 

Electric power input in

power modes other than

 

 

 

Annual electricity consumption

 

 

 

 

'active mode'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off mode

POFF

 

0,0

 

kW

cooling

QCE

 

261

 

kWh/a

standby mode

PSB

 

0,0

 

kW

heating/Average

QHE

 

1658

 

kWh/a

thermostat-off mode

PTO

 

0,0

 

kW

heating/Warmer

QHE

 

-

 

kWh/a

crankcase heater

PCK

 

0,0

 

kW

heating/Colder

QHE

 

-

 

kWh/a

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity control (indicate one of three options)

 

 

 

Other items

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fixed

N

 

 

 

Sound power level

LWA

 

57,0/65,0

 

dB(A)

 

 

 

(indoor/outdoor)

 

 

 

 

 

 

 

 

 

 

 

 

 

staged

N

 

 

 

Global warming

GWP

 

1975

 

kgCO2 eq.

 

 

 

potential

 

 

 

 

 

 

 

 

 

 

 

 

 

variable

Y

 

 

 

Rated air flow

-

 

840/2280

 

m3/h

 

 

 

(indoor/outdoor)

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact details for

 

 

 

 

 

 

 

 

 

 

 

obtaining more

http://www.samsung.com

 

 

 

 

 

 

 

 

 

information

 

 

 

 

 

 

 

 

 

 

 

(*)For staged capacity units, two values divided by a slash ('/') will be declared in each box in the section 'Declared capacity of the unit' and 'declared EER/COP' of unit.

(**)If default Cd = 0,25 is chosen then (results from) cycling tests are not required. Otherwise either the heating or cooling cycling test value is required.

Image 1
Contents According to Commission Regulation EU No 206/2012 ErP InformationAC Product
Related manuals
Manual 27 pages 22.46 Kb Manual 25 pages 59.59 Kb Manual 25 pages 21 Kb Manual 26 pages 19.38 Kb Manual 1 pages 26.59 Kb

AR18FSFPESNXEU, AR18FSFPESNNEU specifications

The Samsung AR18FSFPESNNEU and AR18FSFPESNXEU are advanced inverter air conditioners designed to enhance indoor comfort while promoting energy efficiency and eco-friendliness. These models are equipped with a range of features and technologies that set them apart in the competitive market of air conditioning units.

One of the most notable aspects of these air conditioners is their digital inverter technology. This innovative system allows the compressor to operate at variable speeds, which significantly reduces energy consumption compared to traditional units. By maintaining a consistent temperature without the frequent on-and-off cycles typical in conventional air conditioning, the AR18FSFPESNNEU and AR18FSFPESNXEU ensure quieter operation and lower electricity bills.

Both models boast a cooling capacity of 1.5 tons, making them ideal for medium-sized rooms. The powerful cooling and heating options provide comfort throughout the year, seamlessly transitioning between modes to suit seasonal needs. The units have a wide operating range, ensuring efficient performance even in extreme temperatures. This versatility allows users to enjoy a comfortable climate regardless of external weather conditions.

The design of these air conditioners reflects Samsung's commitment to style and functionality. The sleek, modern appearance fits well with various interior settings, while the plastic finish makes them easy to clean and maintain. Smart features, such as the LED display and intuitive remote control, enhance user experience, allowing for easy adjustments at your convenience.

Another key characteristic of the AR18FSFPESNNEU and AR18FSFPESNXEU is their advanced filtration system. The units come equipped with a 3M micro dust filter that captures fine dust and allergens, creating a healthier indoor environment. This feature is particularly beneficial for allergy sufferers and those with respiratory issues, ensuring cleaner air circulates in the living space.

The air conditioners also incorporate a "Good Sleep" mode, which optimizes cooling and heating throughout the night to foster a comfortable sleeping environment. This feature aligns with Samsung's vision of creating products that enhance everyday living.

In summary, the Samsung AR18FSFPESNNEU and AR18FSFPESNXEU are powerful, efficient, and stylish air conditioning units that provide effective climate control, energy savings, and improved air quality. With their innovative technologies and user-friendly features, these models are an excellent choice for anyone seeking to elevate their indoor comfort.