Lightolier SKS2GPK217, SKS2GPK317 Ordering Information, Options/Accessories, Specifications

Page 2

Skyway SKS2GPK217 or 317

Page 2 of 2

2' x 2' Recessed Fluorescent, Tri-Lens Frame Static or Air Supply/Return, 2 or 3 Lamp T8

Model No. SKS2GPK217UNVHI

LER = FP - 58.1 IW - 31.7 BF - 0.93 Comparative yearly lighting energy cost per

1000 lumens = $4.13

Report Number: G2008293

Catalog Number: SKS2GPK217UNVHI

Lamps: (2) F17T8/TL835/PLUS/ALTO

Luminaire: Skyway Recessed 2' x 2' fixture prismatic acrylic lens assembly.

Ballast: ICN-2P32-SC

Report is based on 1400 Lumens per lamp. Efficiency: 70.7%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.3

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

21.600

 

21.600

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

78

75

72

70

68

66

67

66

64

02

71

66

61

62

59

56

60

57

54

03

65

59

53

55

51

48

53

50

47

04

60

52

47

50

45

41

48

44

41

05

56

47

41

45

40

36

44

39

36

06

52

43

37

41

36

32

40

35

32

07

48

39

33

37

32

29

36

32

28

08

45

36

30

34

29

26

33

29

26

09

42

33

27

32

27

23

31

26

23

10

39

30

25

29

25

21

29

24

21

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

845

845

845

 

5

839

838

839

80

15

796

797

801

225

25

714

727

752

337

35

602

648

695

405

45

459

477

474

367

55

297

308

287

270

65

171

175

162

175

75

89

86

79

94

85

21

24

17

26

90

7

7

3

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

642

22.9

32.4

00-040

1047

37.4

52.9

00-060

1684

60.1

85.1

00-090

1979

70.7

100.0

90-180

0000

0.0

000.0

00-180

1979

70.7

100.0

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

2156.

2240.

2226.

55

1720.

1783.

1662.

65

1344.

1375.

1273.

75

1142.

1103.

1014.

85

800.

914.

648.

Model No. SKS2GPK317UNVH3

LER = FP - 46.8 IW - 46.6 BF - 0.93 Comparative yearly lighting energy cost per

1000 lumens = $5.13

Report Number: G2008296

Catalog Number: SKS2GPK317UNVH3

Lamps: (3) F217T8.TL835/PLUS/ALTO

Luminaire: Skyway Recessed 2' x 2' fixture prismatic acrylic lens assembly.

Ballast: ICN-3P32-SC

Report is based on 1400 Lumens per lamp. Efficiency: 72.9%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.1

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

21.600

 

21.600

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

80

77

74

72

70

68

69

68

66

02

74

68

64

64

61

58

62

59

56

03

68

61

55

57

53

49

55

52

49

04

62

54

48

51

47

43

50

46

42

05

58

49

43

47

42

38

45

41

37

06

53

44

38

42

37

33

41

37

33

07

50

40

34

39

34

30

38

33

30

08

46

37

31

36

31

27

35

30

27

09

44

34

29

33

28

24

32

28

24

10

41

32

26

31

26

22

30

25

22

CANDELA DISTRIBUTION

 

0.0

45.0

90.0

FLUX

0

1391

1391

1391

 

5

1384

1378

1381

131

15

1312

1309

1315

370

25

1175

1172

1166

539

35

984

952

956

602

45

720

714

732

553

55

447

475

435

412

65

260

274

249

269

75

140

131

125

145

85

33

35

28

39

90

12

13

5

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

1040

24.8

34.0

00-040

1642

39.1

53.7

00-060

2607

62.1

85.2

00-090

3060

72.9

100.0

90-180

0000

0.0

000.0

00-180

3060

72.9

100.0

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

3382.

3353.

3438.

55

2588.

2750.

2519.

65

2043.

2153.

1957.

75

1796.

1681.

1604.

85

1257.

1334.

1067.

Ordering Information

Explanation of Catalog Number. Example: SKS2GPK217UNVHI

2

P

K

17

Skyway

Recessed

Fluorescent

SK

SY

NK

Body Style:

Fixture

Ceiling Type:

Side Lens:

Center Lens:

Lamp

Lamp:

Voltage:

 

 

 

 

 

 

 

 

 

Options:

S = Static

Width

G = Standard

P= Frost White

K= Pattern 19

Quantity

(By Others)

120, 277 or

 

 

 

Add appropriate

A = Air

 

Grid

Acrylic Lens

.156 Virgin

2=2 Lamp

17 =T8 17W

UNV=120-277

 

 

 

suffix to catalog

 

 

T = Slot Grid

 

Acyrlic Lens

3=3 Lamp

(Nominal 24")

 

 

 

 

 

no., ie: (A)

 

 

 

 

 

 

 

Ballast Type:

 

Ballast

Standard Skyway

 

 

 

 

 

 

 

 

<20THD

<10THD

 

 

 

 

 

 

 

 

Factor

 

 

 

 

 

 

 

1 or 2 Lamp Elec. T8

SO*

HI*

0.88

For NYC Code – I.B.E.W. Manufactured

 

 

 

 

 

1-3 Lamp Elec. T8

O3*

H3*

0.88

 

 

 

 

 

Advance Optanium

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For NYC Code – Local 3 Manufactured

 

 

 

 

 

1 or 2 Lamp Elec. T8

C5*

0.80

 

 

 

 

 

1 - 3 Lamp Elec. T8

C6*

0.81

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOL Dimming T8

PS*

 

 

 

 

 

 

 

 

*Instant Start Standard

 

 

Options/Accessories

Fusing: Internal fast blow fusing: SUFFIX: A.

Internal slow blow fusing: SUFFIX: C.

Drywall Kit: Order Catalog Number: FK92X2.

Electrical Wiring Options: Consult factory.

For motion or light sensor: See Folio OA20-10 and OA20-30.

Specifications

Performance: In an installation of 2 lamp 17W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .75. To reduce glare the average brightness at 65° shall not exceed 1375 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 67.6%.

Air Handling: (SKA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provid- ed through the lamp compartment through fixture body ends.

Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing has side rails hemmed over and housing ends turned-in for safe handling.

Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Rust preventative undercoating. Reflectors- 95% reflective white powder coated.

Other dimming options. Consult factory.

NOTE:

For T8 UNV, you must use HI OR H3 Ballast Code.

Specifications (continuned)

Lens: Proprietary high quailty frost white acrylic and clear conical prism lens assembly.

Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Job Information Type:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

www.lightolier.com © 2009 a Philips Group

Section 5/Folio MA12-14

Lightolier is a Philips group brand

Image 2
Contents Mounting Methods FeaturesDimensions 24 610mm 127mm Air supply slotsSpecifications continuned Options/AccessoriesSpecifications Ordering Information

SKS2GPK317, SKS2GPK217 specifications

The Lightolier SKS2GPK317 and SKS2GPK217 are innovations in the realm of modern lighting solutions, offering users a blend of efficiency, design, and versatility. These LED fixtures are particularly favored for both commercial and residential applications, showcasing a range of features and technologies that set them apart from conventional lighting options.

One of the standout characteristics of the SKS2GPK317 and SKS2GPK217 is their energy efficiency. Designed with advanced LED technology, these fixtures consume significantly less power than traditional incandescent bulbs while providing an impressive level of brightness. This not only helps in reducing electricity bills but also contributes to a smaller carbon footprint, making them an environmentally friendly choice.

Both models are equipped with a robust construction designed to withstand the rigors of daily use. The SKS2GPK317 boasts a durable housing that is resistant to rust and corrosion, ensuring longevity even in challenging environments. The SKS2GPK217, while lighter in design, maintains high durability standards, allowing for flexibility in installation without compromising on strength.

In terms of illumination, these fixtures offer exceptional light quality. With a high Color Rendering Index (CRI), the SKS2GPK317 and SKS2GPK217 render colors accurately, enhancing the visual appeal of spaces. They also feature adjustable lumen output, allowing users to tailor the brightness according to their specific needs, whether for general lighting or task-oriented areas.

Installation is made simple with these models, thanks to their compatibility with various mounting options. They can easily integrate into existing fixtures, making upgrades seamless for users wanting to enhance their lighting setup without undergoing extensive renovations.

Furthermore, both models incorporate intelligent design features such as low heat generation, which prolongs the lifespan of the fixtures and reduces maintenance costs. This thermal efficiency is particularly crucial in spaces where heat buildup can be problematic.

In conclusion, the Lightolier SKS2GPK317 and SKS2GPK217 represent a significant leap forward in lighting technology. With their energy efficiency, high-quality illumination, durable construction, and thoughtful design features, they offer an optimal solution for any lighting needs, proving that modern advancements can lead to significant improvements in functionality and aesthetics. Whether used in homes, offices, or commercial settings, these fixtures embody the future of lighting.