Lightolier MD4GPSVA2SB4SB dimensions Ambient Light, Reading Light, Examination Light

Page 2

MD*4TM 2' x 4' Recessed or Surface MD4GPSVA2SB4SB

Page 2 of 4

Multi-Function Patient Lighting

Ambient Light

 

 

 

 

 

 

 

 

 

 

 

Indirect illumination from wall directly behind patient provides glare-free lighting..

 

 

 

 

 

 

 

 

No direct glare to patient. (Light is directed towards wall.)

 

 

 

 

 

 

 

 

 

 

 

No direct glare to patient's visitor.

 

 

 

 

 

 

 

 

 

ADJACENT

 

No direct glare to adjacent patients. (3 footcandles maximum on wall behind adjacent patients bed.)

 

 

 

 

 

 

 

 

AMBIENT LIGHT

 

 

 

 

 

 

 

MD*4

 

 

 

 

ON

 

 

 

 

 

 

 

OFF

 

 

45

110

140

110

45

14

4

2

1

1

1

1

LIGHTED

SHIELDED

 

 

 

 

 

 

 

 

 

 

 

ZONE

ZONE

83

95

83

44

19

7

3

2

2

1

1

 

44

 

30

45

50

45

30

16

8

4

3

3

2

1

 

16

20

22

20

16

11

7

4

3

3

2

1

 

7

9

 

9

7

4

3

2

2

 

1

1

 

3

 

 

 

3

2

2

1

 

 

 

1

 

 

 

 

 

1

2

1

1

 

 

 

 

Reading Light

Eliminates reflected glare from reading material (over shoulder illumination).

No direct glare to patient or visitors. (7 footcandles maximum at head of bed. 15 footcandles maximum at foot of bed.)

Controls light directly onto patient's bed.

No reading light spill-over to adjacent bed (2 foot/candles maximum at head of adjacent patient's bed.)

ADJACENT

LIGHTED

SHIELDED ZONE

ZONE

Illumination at the reading task ranges 50-60 footcandles.

 

 

 

 

 

 

 

READING LIGHT

 

FOOTCANDLES ON BEDS

 

MD*4

 

 

 

 

 

 

 

 

3"↓

 

 

 

 

ON

 

 

OFF

 

 

 

 

↓3"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6"

 

 

 

 

 

 

 

 

WALL

 

 

 

 

 

 

 

 

6"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

2

2

2

2

2

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12"

 

 

 

 

3

 

3

3

3

3

2

2

2

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

6

 

7

7

7

6

4

3

3

2

2

1

1

 

 

 

 

 

 

33

 

38

39

38

33

23

16

12

9

5

3

2

 

 

 

 

 

 

30

 

38

38

38

30

23

15

12

8

6

3

2

 

 

 

 

 

 

14

 

15

15

15

14

11

9

7

5

4

2

2

 

 

 

 

 

 

5

 

5

5

5

5

5

4

4

2

2

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BED

 

 

 

 

 

 

BED

 

12"

 

 

 

 

 

 

 

 

Illumination at the reading task range 50-60 footcandles

 

 

 

 

 

 

 

 

 

 

 

 

 

LIGHTED

ZONE

Examination Light

Excellent color rendition. (Biax Type lamp.)

Wired for independent switching (1 or 2 circuit).

Optional louver or lens frame.

Concealed hinging and latching.

FOOTCANDLES ON BED (with Specular Louver) 3"←→6" ← 12" Totals of ambient, reading and examination lights.

70

82

82

102

100

70

48

 

 

 

 

(11)

(12)

(15)

(45)

(43)

(20

(10)

 

 

 

 

 

 

 

 

 

 

 

 

12"

75

82

86

107

102

72

48

 

 

(11)

(12)

(15)

(45)

(43)

(20)

(10)

 

 

 

 

70

82

82

102

100

70

48

 

 

 

 

(11)

(12)

(15)

(45)

(43)

(20)

(10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BED Numbers in parenthesis ( ) are total footcandle level of ambient and reading lights only.

Image 2
Contents Job Information Type FeaturesMounting Methods Dimensions Now available in 3 stylesExamination Light Ambient LightReading Light No direct glare to patients visitorNurses Night Light Optional NL or LD OptionsJob Information Options/AccessoriesSpecifications