Lightolier PLA2G9LS26U Photometry, Ordering Information, Options/Accessories, Specifications

Page 2
Section 2/Folio G50-52 Rev. A

 

Paralyte 2424 PLA2G9LS26U

Page 2 of 2

2’ x 2’ Recessed Fluorescent, 3-1/8" Deep 9 Cell Parabolic Louver,

 

Static and Air Return, 2 Lamp, T8 or T12

Photometry

Model No. PLA2G9LS26U120SO

ITL40489

LIGHTOLIER

PLA2G9LS26U120SO

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.

LER = FP - 58.9

IW - 58.0 BF - 0.87

 

 

 

 

 

 

 

 

Comparative yearly lighting energy cost per 1000 lumens = $4.07

 

 

 

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

 

 

 

 

RF

 

 

20

 

 

 

 

20

 

 

 

 

 

20

 

 

RC

 

 

80

 

 

 

 

50

 

 

 

 

 

30

 

 

RW

 

70

50

 

30

 

50

30

 

10

 

50

 

30

10

 

1

 

76

73

 

71

 

69

67

 

65

 

66

 

65

63

ratio

2

 

70

65

 

61

 

61

58

 

56

 

59

 

57

54

3

 

64

58

 

53

 

55

51

 

47

 

53

 

49

47

cavity

4

 

59

51

 

46

 

49

44

 

41

 

47

 

43

40

5

 

54

46

 

40

 

44

39

 

35

 

43

 

38

35

room

6

 

50

42

 

36

 

40

35

 

31

 

39

 

34

31

7

 

47

38

 

32

 

36

31

 

28

 

35

 

31

27

 

8

 

43

34

 

29

 

33

28

 

25

 

32

 

28

25

 

9

 

40

32

 

26

 

30

26

 

22

 

30

 

25

22

 

10

 

38

29

 

24

 

28

23

 

20

 

27

 

23

20

visual comfort probability (rated lumens per lamp 3150.)

 

 

 

 

 

 

 

 

 

room size

 

 

 

 

ceiling height

 

 

 

 

 

ceiling height

 

 

W

 

 

L

 

 

8.5

10.0

13.0

16.0

 

 

 

8.5

10.0

13.0

 

16.0

20

 

 

20

 

 

71

66

69

79

 

 

 

68

63

63

 

76

20

 

 

30

 

 

74

70

66

68

 

 

 

71

67

62

 

61

20

 

 

40

 

 

77

73

70

68

 

 

 

74

70

66

 

63

20

 

 

60

 

 

79

75

73

71

 

 

 

76

72

69

 

66

30

 

 

20

 

 

76

70

67

76

 

 

 

74

68

63

 

74

30

 

 

30

 

 

79

73

66

65

 

 

 

76

71

63

 

60

30

 

 

40

 

 

81

75

69

66

 

 

 

78

73

67

 

62

 

 

 

 

 

 

 

 

30

 

 

60

 

lengthwise

82

77

72

68

 

 

crosswise

80

75

70

 

65

30

 

 

80

 

84

79

74

71

 

 

81

77

72

 

68

 

 

 

 

 

 

 

 

40

 

 

20

 

 

79

73

71

75

 

 

 

76

71

67

 

73

40

 

 

30

 

 

81

76

69

64

 

 

 

79

74

67

 

61

40

 

 

40

 

luminaries

83

78

72

65

 

 

luminaries

81

76

70

 

63

40

 

 

60

 

84

80

74

68

 

 

82

78

72

 

66

40

 

 

80

 

 

85

81

76

70

 

 

 

83

79

74

 

68

40

 

 

100

 

 

86

82

78

73

 

 

 

84

80

76

 

70

60

 

 

30

 

 

82

78

72

67

 

 

 

80

76

70

 

63

60

 

 

40

 

 

84

80

74

67

 

 

 

82

78

73

 

65

60

 

 

60

 

 

85

81

76

70

 

 

 

83

80

75

 

68

60

 

 

80

 

 

86

83

78

72

 

 

 

84

81

77

 

70

60

 

 

100

 

 

87

84

80

74

 

 

 

85

82

78

 

72

100

 

 

40

 

 

84

80

76

71

 

 

 

82

78

75

 

69

100

 

 

60

 

 

86

82

78

73

 

 

 

84

80

77

 

71

100

 

 

80

 

 

87

84

80

75

 

 

 

85

82

79

 

74

100

 

 

100

 

 

88

85

81

77

 

 

 

86

83

80

 

75

Ordering Information

Explanation of Catalog Number. Example: PLA2G9LS26U120SOGLR

PL

 

 

A

 

 

2

 

G

 

9

 

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Paralyte

 

Body

Style:

 

Fixture

Ceiling Type:

Number of

 

 

Ballast Cover:

2424:

 

A= Air Handling

 

Width

G=Grid (lay-in T-bar)

Cells

 

 

S=Single V Reflector

3-1/8" Deep

 

/Static

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parabolic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Louver Finish:

Precision

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contoured Pre-

 

 

 

 

 

 

 

 

 

 

 

 

 

L =

Low

anodized

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Iridescence

Aluminum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi-specular

Louver

 

 

 

 

 

 

 

 

 

 

 

 

 

W =

(standard)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White Paint

2

Lamp

Quantity

6U

Lamp/

Fixture Length:

6" U Lamp T8 or T12 (Nominal 24")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage:

 

 

Options:

120 or 277

 

Add appropriate

 

 

 

 

 

suffix to catalog

 

 

 

 

 

 

no, ie: (GLR)

 

 

 

Ballast Type:

 

 

 

1–2 Lamp Mag. T12

LE*

<10THD

 

 

 

 

<20THD

1–2 Lamp Elec. T8

SO*

HI*

LOL T8 Dimming

PS*

*Instant Start Standard

Other dimming options. Consult factory.

Options/Accessories

Prewiring: 3/8" factory prewired cable (three no. 18 AWG leads, 6’ long).

Suffix: FF6, (Four no. 18 AWG leads, 6’ long). Suffix: FF14.

Fusing: Internal fast-blow fusing. Suffix: GLR. Internal slow-blow fusing Suffix: GMF.

Fluorescent Emergency Lighting System: Factory-installed emergency power battery pack with charger and inverter, concealed in fixture channel. Operates one fluorescent lamp at reduced light output for 90 minutes. Suffix: EM.

Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz.

One per fixture. Suffix: R. One per ballast. Suffix: B.

Electrical Options: Special wiring, fusing or dimming ballasts and installed lamps are available, consult your Lightolier representative or factory.

T-Bar Spacer: If T-bar is less than 1-1/2" deep, order Catalog Number: STC. 2 each end is required.

Specifications

Performance: In an installation of 2 lamp 31W Iuminaires in a room cavity ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than 73. To prevent glare the VCP shall not be less than 83 either lengthwise or crosswise (at 10Ofc level) and the average brightness at 65° shall not exceed 2817 candelas per square meter. To control veiling reflections, Iuminaire output in the 30°-90° zone shall not be less than 68.9%.

Specifications (continued)

Air Return: Designed to provide optimum air return. Air is returned through the lamp compartment for all ceiling systems and direct to plenum through slots in slot grid and narrow grid ceiling systems.

Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is embossed for rigidity with all edges turned up for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal).

Finish: Louver–semi-specular anodized low iridescence, vertical grain reflector sheet. Cavity–white baked polyester minimum 86% refLectance. Phosphate undercoating. Chassis exterior–black baked polyester enamel.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O.is within 3“ of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and ULc Listed.

Job Information

 

Type:

 

 

 

Lightolier a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2003 Genlyte Thomas Group LLC (Lightolier Division) A0902

Image 2
Contents Features DimensionsOrdering Information Options/AccessoriesPhotometry Specifications

PLA2G9LS26U specifications

The Lightolier PLA2G9LS26U is a cutting-edge lighting solution that seamlessly integrates contemporary design with advanced lighting technology. It is particularly well-suited for both residential and commercial spaces, offering efficiency and aesthetics in one comprehensive package.

One of the standout features of the PLA2G9LS26U is its energy efficiency. Utilizing LED technology, it consumes significantly less power compared to traditional incandescent fixtures while delivering superior light output. This not only reduces energy costs but also minimizes the carbon footprint, aligning with modern sustainability goals. The fixture boasts a high lumen output that ensures bright, effective illumination in any setting.

The design of the Lightolier PLA2G9LS26U is another key aspect of its appeal. With a sleek and modern aesthetic, it fits seamlessly into various styles of décor, from minimalist to contemporary. The fixture is available in multiple finishes, allowing for customization based on personal preference or the specific requirements of the space. Its low-profile design makes it ideal for areas with limited ceiling heights, providing a stylish solution without compromising on brightness.

In terms of technology, the PLA2G9LS26U features advanced thermal management capabilities. The fixture is designed to dissipate heat effectively, which not only enhances its longevity but also ensures consistent performance over time. Additionally, the integration of smart technology allows for compatibility with modern lighting control systems, providing users with the ability to dim or adjust lighting levels according to their needs.

The versatility of the Lightolier PLA2G9LS26U is further enhanced by its ability to be installed in various configurations. Whether mounted on a surface or suspended from the ceiling, it adapts effectively to different environments, making it a preferred choice for both residential and commercial installations.

Another defining characteristic is the color temperature options available. Users can select from a range of color temperatures, ensuring that the lighting can be tailored to enhance mood and functionality in any space.

In summary, the Lightolier PLA2G9LS26U combines energy efficiency, modern design, and advanced technology to deliver an exceptional lighting solution. Its versatile applications, along with smart features and customizable aesthetics, make it an ideal choice for those looking to enhance their lighting experience while remaining environmentally conscious.