SS Staggered Strip Surface Fluorescent SS 1 LAMP
Page 2 of 2
Photometry
REPORT NO: G89007
CATALOG NO: SS4S132HPF120SO
LAMP TYPE: 1F32 T8
LUMENS PER LAMP: 2850 TOTAL
EFFICIENCY: 89.5%
CIE TYPE:
SPACING CRITERIA: 1.6
SHIELDING ANGLE: 180
Model No. SS4S132HPF120SO
coefficients of utilization — zonal cavity method | (effective floor cavity reflectance 0.20) |
|
| ||||||||
| RF |
| 20 |
|
| 20 |
|
| 20 |
| |
| RC |
| 80 |
|
| 50 |
|
| 30 |
| |
| RW | 70 | 50 | 30 | 50 | 30 | 10 | 50 | 30 | 10 | |
| 1 | 89 | 84 | 79 | 71 | 68 | 64 | 64 | 61 | 58 | |
ratio | 2 | 80 | 71 | 64 | 60 | 55 | 51 | 54 | 50 | 46 | |
3 | 72 | 62 | 53 | 52 | 46 | 41 | 47 | 42 | 38 | ||
cavity | 4 | 65 | 54 | 45 | 46 | 39 | 34 | 41 | 36 | 31 | |
5 | 59 | 47 | 39 | 40 | 34 | 28 | 36 | 30 | 26 | ||
room | 6 | 54 | 42 | 33 | 36 | 29 | 24 | 32 | 26 | 22 | |
7 | 50 | 37 | 29 | 32 | 25 | 21 | 29 | 23 | 19 | ||
| |||||||||||
| 8 | 46 | 33 | 25 | 29 | 22 | 18 | 26 | 20 | 16 | |
| 9 | 43 | 30 | 22 | 26 | 20 | 15 | 23 | 18 | 14 | |
| 10 | 40 | 27 | 20 | 24 | 18 | 13 | 21 | 16 | 12 |
Ordering Information
Explanation of Catalog Number. Example: SS4S132HPF120SOGLR†
SS |
|
|
|
|
|
|
| 1 |
|
|
|
| HPF | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Staggered Strip: | Fixture Length: | Lamp Configuration: | Lamp Quantity |
2=24" | S=Standard |
| |
channel | 3=36" | T= 3' or 4' Lamps |
|
| 4=48" | in Tandem |
|
| 6=69" | (for 6' or 8' Units) |
|
| 8=93" |
|
|
†No Product Change. New Catalog Number Designation.
Options/Accessories
Fusing: Internal
Internal
Electrical Wiring Options: Consult factory.
Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture.
Suffix: R. One per ballast. Suffix: B.
Stem and Canopy Sets: Suspends fixture 6', 12', 18' or 24' from surface.
Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"),
ASC24 CSP (24").
Lamps:
(By Others)
17=17 watt (T8)
20=20 watt (T12) (Nominal 24")
25=25 watt (T8)
30=30 watt (T12) (Nominal 36")
32=32 watt (T8)
34=34 watt (T12) (Nominal 48")
(One lamp in tandem
for 69" and 93" fixtures)
Ballast Type:
HPF=High Power
Factor
Voltage: |
| Options: | |
120 or 277 |
| Add appropriate | |
Ballast: | suffix to catalog | ||
no., ie: (GLR) | |||
1 or 2 Lamp Mag. T12 | LE | ||
| |||
Standard Electro- |
|
| |
Magnetic (20 or | P |
| |
30 watts only) |
| ||
| <20THD | <10THD | |
1 or 2 Lamp Elec. (T8) | SO* | HI* | |
LOL Dimming (T8) | PS | – |
*Instant Start Standard
Other dimming options. Consult factory.
Specifications
Materials: Chassis parts are die formed heavy duty code gauge cold rolled steel.
Ballast
Finish: Chassis
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
Job Information | Type: |
|
|
Lightolier a Genlyte Thomas Company | www.lightolier.com |
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508)
© 2003 Genlyte Thomas Group LLC (Lightolier Division) A0303