Samsung AR24KRFHCWKNMG manual English-36, On a Wall, If you fix the indoor unit on a gypsum board

Page 36

1.Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65 mm so that it slants slightly downwards.

Pipe hole

 

(Ø65mm)

 

A

D

B

C

Make sure to drill only one hole after choosing the direction of the pipe.

 

 

 

 

 

 

 

(Unit : mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

A

B

C

 

D

 

Plastic

 

 

 

 

 

 

 

 

 

 

 

 

 

18/24

38

70

156

 

38

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Anchor

 

 

 

 

 

 

 

 

 

2. Fix the indoor unit.

 

 

 

 

 

 

<

 

 

20 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If you fix the indoor unit

on a

wall

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1) Fix the installation plate to the wall giving attention to the weight of the indoor unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• If you mount the plate to a concrete wall using plastic anchors, make sure that gaps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

between the wall and the plate, created by projected anchor, is less than 20 mm.

 

 

 

 

 

 

 

 

 

 

 

If you fix the indoor unit

on a

window frame

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)Determine the positions of the wooden uprights to be attached to the window frame.

(2)Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.

(3)Attach the installation plate to the wooden upright using tapping screws.

If you fix the indoor unit on a gypsum board

(1)Use stud finder to find out locations of the studs.

(2)Fix the plate hanger on two studs.

Wall

Search for other spots if there are less than two studs, or the distance between the studs are different from the plate hanger.

Fix the installation plate without inclining to one side.

Make sure that a wall can withstand the weight of the product. If you install the product in a place where it is not

strong enough to withstand the product weight, the unit could fall and cause injury.

English-36

MG_BORACAY_IB&IM_EN_DB68-05789A-00.indd 36

12/4/2015 4:48:08 PM

Image 36
Contents Air Conditioner Features of your new air conditioner Contents Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9Smart install Checking before useOperation ranges English-10Technical Specifications English-11N02asicbctiofun Power button Checking the name of the partsMain parts DisplayChecking the remote controller Remote controller buttonsEnglish-13 Remote controller display Low Battery warningStoring the remote controller Inserting the batteriesBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-16 Adjusting the air flow direction Vertical air flowHorizontal air flow English-17Setting the On/Off timer Setting the On timerSet the timer to press the SET button You can adjust the fan speed in Cool/Fan/Heat modeSetting the Off timer Set the timer toEnglish-19 Button Additional options available in mode ModeEnglish-20 Step cooling function English-21Press the Options button Press the SET button to set the 2-Step Cooling functionUsing the Fast function Using the Comfort functionSet temperature and fan speed cannot be adjusted English-22Using the Single User function English-23Press the Single user button Using the Auto Clean function Setting the Beep soundEnglish-24 Cleaning the air conditioner Cleaning the outdoor unit heat exchangerOpening the panel English-25Cleaning the air filter Removing the Air filterEnglish-26 Open the panel and put the Air filter outMaintaining the air conditioner English-27Troubleshooting Air conditionerEnglish-28 Button or disconnect the power plug/switch Check the Drains have been cleared Regular MaintenanceError is indicated Heard when refrigerant flow movement changes. It is normalGeneral information English-30Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker Indoor unitWhere sulfide gas exists Outdoor UnitEnglish-32 Noise and vibrationWhen installing more than 1 outdoor unit English-33Top view Side view Accessories Accessories in the indoor unit caseAccessories in the outdoor unit case English-34Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsEnglish-36 On a WallOn a If you fix the indoor unit on a gypsum boardConnecting the assembly cable Cable specificationConnecting the cable English-37Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-38 18/24KR English-39 Smooth the cut edgesCut off the remaining foam insulation TorqueEvacuating the indoor unit Cutting or extending the pipeEnglish-40 English-41 Drain hose installation English-42Correct connection Incorrect connection Drain hose Pipe Two hoses are firmly connected, there is no water leakageChange the direction only when it is necessary Changing direction of the drain hoseEnglish-43 Check for leakage on both side of the drain outletEvacuating the connected pipes English-44Connect a drain hose to the drain plug Drain hole Drain plugAdding Refrigerant English-45Outer Torque If you use a pipe longer than 5 mEnglish-46 Cylinder with siphonPerforming the gas leak tests English-47Outdoor unit installed on the wall by rack Fixing the outdoor unit in placeEnglish-48 Smart Install mode English-49English-50 Off / Blinking / OnFinal check and trial operation English-51Packing and unpacking guide English-52How to connect your extended power cables English-53Apply heat to the contraction tube to contract it Atio After tube contraction work is completed, wrap it withEnglish-54 English-55 Questions or COMMENTS? 021-8255 CE

AR18KQFHCWKNMG, AR24KRFHCWKNMG, AR24KQFHCWKNMG, AR18KRFHCWKNMG specifications

Samsung has long been a frontrunner in the HVAC (Heating, Ventilation, and Air Conditioning) industry, and its innovative range of split air conditioners, including models AR18KRFHCWKNMG, AR24KQFHCWKNMG, AR24KRFHCWKNMG, and AR18KQFHCWKNMG, exemplifies the brand’s commitment to performance, efficiency, and comfort. These models serve varying room sizes and needs, making them ideal for residential and commercial spaces alike.

One of the standout features across these models is the advanced inverter technology. This technology allows the compressor to operate at variable speeds, adjusting to temperature fluctuations seamlessly. As a result, users benefit from higher energy efficiency and lower electricity bills, while also enjoying a consistent and comfortable indoor climate. The Digital Inverter technology reduces unnecessary energy consumption compared to traditional non-inverter models.

Another key feature of these air conditioners is the triple filtration system. Samsung’s air purifying filters capture dust, allergens, and harmful particles, ensuring a healthier environment. This system includes a reusable and washable filter that promotes ease of maintenance and extends the lifespan of the unit, which is ideal for users who prioritize cleanliness and air quality.

Additionally, noise reduction technology makes these models exceptionally quiet, enhancing user comfort. With operational noise levels kept to a minimum, individuals can enjoy a peaceful atmosphere whether at home or at work, making these units perfect for bedrooms and quiet environments.

These models are also equipped with Smart features, allowing remote control via a smartphone app. Users can monitor and adjust settings from virtually anywhere, adding convenience to their daily lives. The presence of one-touch controls simplifies the user experience, allowing for quick adjustments as needed.

Moreover, the sleek and modern design of the AR18KRFHCWKNMG, AR24KQFHCWKNMG, AR24KRFHCWKNMG, and AR18KQFHCWKNMG ensures that they blend well with contemporary interiors. Their aesthetic appeal, coupled with functional excellence, makes them an attractive addition to any space.

In conclusion, Samsung’s AR18KRFHCWKNMG, AR24KQFHCWKNMG, AR24KRFHCWKNMG, and AR18KQFHCWKNMG air conditioners stand out due to their innovative technologies, energy efficiency, advanced filtration systems, noise reduction capabilities, and smart functionality. These features, along with their stylish designs, make them an excellent choice for anyone looking to enhance their indoor comfort while prioritizing health and efficiency.