Chicago Electric 95563 Grounded Tools Tools With Three Prong Plugs, Extension Cords, See Table a

Page 6

Grounded Tools: Tools With Three Prong Plugs

The Ultrasonic Cleaner has a 3-prong plug.

1.Tools marked with “Grounding Required” have a three wire cord and three prong grounding plug. The plug must be connected to a properly grounded outlet. If the tool should electrically malfunction or break down, grounding provides a low resis- tance path to carry electricity away from the user, reducing the risk of electric shock.

(See 3-Prong Plug and Outlet.)

2.The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool. The green wire in the cord must be the only wire connected to the tool’s grounding system and must never be attached to an electrically “live” terminal. (See 3-Prong Plug and Outlet.)

3.Your tool must be plugged into an appropriate outlet, properly installed and grounded in accordance with all codes and ordinances. The plug and outlet should look like those in the following illustration. (See 3-Prong Plug and Outlet.)

3-Prong Plug and Outlet

Extension Cords

1.Grounded tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extension cord.

2.As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wire causes a seri- ous drop in voltage, resulting in loss of power and possible tool damage.

(See Table A.)

3.The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord.

(See Table A.)

4.When using more than one extension cord to make up the total length, make sure each cord contains at least the minimum wire size required. (See Table A.)

SKU 95563

For technical questions, please call 1-800-444-3353.

Page

Image 6
Contents Liter, non-medical ultrasonic cleaner For technical questions or replacement parts, please callElectrical Safety SpecificationsGeneral Safety Rules Save This ManualPersonal Safety Specific product warnings and precautions ServiceTool Use And Care Never immerse the Ultrasonic Cleaner in liquid GroundingSee 3-Prong Plug and Outlet Grounded Tools Tools With Three Prong PlugsExtension Cords Prong Plug and OutletSymbology FeetAt full load Choosing a cleaning cycle UnpackingOperation Cleaning with heat INSPECTION, MAINTENANCE, and CleaningProblem Possible Causes Probable Solutions TroubleshootingParts List Part Description ’tyAssembly diagram Warranty Record Product’s Serial Number Here