A)Outlet Pair Always On (Unswitched): For components (such as your VCRs) that need to retain memory, set left slide switch to UNSWITCHED and the right slide switch to either DELAY or NO DELAY (fig. 2a).
B)Outlet Pair Switched On: Set the left slide switch to SWITCHED and the right slide switch to NO DELAY. (fig. 2b). The outlet pair will be “live” once the PowerCenter is switched on by pressing the front panel ON button or by external signal (see page 9 and page 10). However, it will remain active for approximately 10 seconds after switching off the PowerCenter.
C)Outlet Pair Switched On After Delay: Set the left slide switch to SWITCHED and the right slide switch to DELAY (fig. 2c). When the PowerCenter is switched on by pressing the front panel ON button or by external signal, the outlet pair will be “live” after a delay set by the DELAY TIME switch. However, the outlet pair will be turned off immediately once the PowerCenter is switched off by pressing the front panel OFF button or by external signal.
D)Delay Time Switch: Set to SHORT, outlets will receive power after a delay of approximately 6 seconds, once the PowerCenter is switched on (fig. 2d). Set to LONG, outlets will receive power after a delay of approximately 20 seconds, once the PowerCenter is switched on. This is the recommended delay setting for
NOTE: This switch affects all outlet pairs which are programmed as “switched on after delay”
E)Trigger Out Programming Switch: Set to DELAY, the 12 volt remote trigger will power an external device after a delay set by the DELAY TIME switch once the PowerCenter is switched on (fig. 2e). Set to NO DELAY, the 12 volt trigger powers an external device as soon as the PowerCenter is switched on.