Desa manual Operation, Model SH-5710, Features, Mode Switching Summary, Requirements

Page 1

Motion Sensor

Light Control

Model SH-5710

Features

Turns on lighting when motion is detected.

Automatically turns lighting off.

Photocell keeps the lighting off during daylight hours.

LED indicates motion was sensed (day or night).

Additional energy savings with compact fluorescent bulbs.

This package includes:

Lamp Holders

Rubber Plug

Plastic Hanger

OPERATION

Mode:

On-Time:

Works: Day

Night

 

 

 

 

Test

5 Sec

x

x

Auto

1, 5, 10 min.

 

x

Manual

Until Dawn*

 

x

 

 

 

 

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

TEST

Put the ON-TIME switch on the bottom

ON-TIME

of the sensor in the TEST position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Put the ON-TIME switch in the 1, 5, or

 

ON-TIME

10 minute position. Note: Although

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the 1 minute mode can be used, the 5

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

or 10 minute mode is recommended

 

 

 

 

 

 

 

 

 

 

for best operation and performance

 

 

 

 

 

 

 

 

 

 

whenusingcompactfluorescentbulbs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MANUAL MODE

 

 

 

 

 

 

 

 

 

 

Cover Plate

Sensor

 

Light Control

 

2 Wire

 

Connectors

Mounting Bolt

Mounting Strap

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.

1 Second OFF

then...

... back on.

2 Compact

Gasket

6 Screws

Mode Switching Summary

Fluorescent Bulbs

(3 sizes included)

TEST

 

 

Move ON-TIME Switch

 

 

 

 

 

 

 

 

to 1, 5, or 10 minutes

Requirements

The Light Control requires 120-volts AC.

If you want to use Manual Mode, the control must be wired through a switch.

Some codes require installation by a qualified electrician.

This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.

Note: This product is not recommended for use where the outside temperature is below -10°F.

 

AUTO

 

Flip light switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off for one second

MANUAL MODE

 

 

then back on*

 

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.

© 2004 DESA Specialty Products™

598-1163-01

Image 1
Contents Mode Switching Summary FeaturesOperation Model SH-5710Wire the Light Control InstallationWall Mount Eave Mount Mount the Light ControlSpecifications Test and AdjustmentBottom of Sensor Technical Service Troubleshooting GuideNo Service Parts Available for this Product TEN Year Limited WarrantyModelo SH-5710 FuncionamientoCaracterísticas RequisitosMontaje en pared Montaje en alero InstalacionConecte EL Control DE LUZ Instale EL Control DE LUZEspecificaciones Prueba Y AjusteParte de abajo del detector Alcance Máximo Angulo deServicio Técnico Guia DE Investigacion DE AveriasNo enviar los productos No hay piezas de servicio disponibles para este producto