Chauvet ST-3000LED user manual Fixture Linking, DMX Da ta Ca ble, Cable Connectors

Page 8

Setup

FIXTURE LINKING

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support.

The ST-3000LED fixtures use 3 channels of DMX control.

Important: Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA-485 standard no more than 32 devices should be connected on one data link. Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal.

Maximum recommended serial data link distance: 500 meters (1640 ft.)

Maximum recommended number of fixtures on a serial data link: 32 fixtures

Data Cabling

To link fixtures together you must obtain data cables. You can purchase CHAUVET certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference.

DMX Da ta Ca ble

Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Standard microphone cables cannot transmit DMX data reliably over long distances. The cable will have the following characteristics:

2-conductor twisted pair plus a shield

Maximum capacitance between conductors – 30 pF/ft. Maximum capacitance between conductor and shield – 55 pF/ft. Maximum resistance of 20/ 1000 ft.

Nominal impedance 100 - 140

Cable Connectors

Cabling must have a male XLR connector on one end and a female XLR connector on the other end.

DMX connector configuration

 

 

 

COMMON

 

1

DMX +

INPUT

3

 

 

2

 

 

 

DMX -

1Resistance 120 ohm ¼ w between

3

pin 2 (DMX -) and

 

2pin 3 (DMX +) of the last fixture.

1

 

3

OUTPUT

2

Termination reduces signal errors and

 

to avoid signal transmission problems

and interference, it is always

advisable to connect a DMX signal

CAUTION Do not allow contact between the common and the fixture’s chassis ground. Grounding the common can cause a ground loop and your fixture to perform erratically. Test cables with OHM meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other.

ST-3000LED User Manual

8

2009-12-10/14:04

Image 8
Contents LED Techno Strobe Table of Contents Before You Begin Unpacking InstructionsContact US Your s hipment include s the fo llow ingImportant Safety Information Protec tion a gainst Elec tric ShockProtec tion a gainst Fire & Bu rns Protec tion a gainst Inju r y to person sFeatures Additional FeaturesIntroduction DMX Channel SummaryProduct Overview Setup MountingDMX Da ta Ca ble Cable ConnectorsFixture Linking Pin to 5 Pin Con versi on Cha rt Setting UP a DMX Serial Data LinkSTANDALONE/MASTER-SLAVE Fixture Linking T u p Standalone ModeOperating Instructions DMX Control Mode Daisy Chain Serial Data LinkReturns Procedure MaintenanceAppendix ClaimsBinary & DMX DIP Switch Addressing Binary Addressing Quick Reference Chart DMX & Binary Address Quick Reference ChartDMX Channel Values Technical Specifications Technical Support