Chauvet SCAN LED 100 user manual Appendix, General Troubleshooting

Page 11

5.APPENDIX

General Troubleshooting

SYMPTOM

POSSIBLE CAUSE(S)

POSSIBLE ACTION(S)

 

• Excessive circuit load

• Check total load placed on the

Breaker/Fuse

electrical circuit.

 

keeps blowing

• Short circuit along the power

• Check for a short in the electrical

 

wires

wiring (internal and/or external).

Device does not

• No power

• Check for power on Mains.

power up

• Loose power cord

• Check power cord

 

• Wrong DMX addressing

• Check Control Panel and unit

 

addressing

 

 

 

• Damaged DMX cables

• Check DMX cables

Fixture is not

• Wrong polarity settings on the

• Check polarity switch settings on

responding to DMX

controller

the controller

 

• Loose DMX cables

• Check cable connections

 

• Faulty DMX interface

• Replace DMX input

 

• Faulty Main PCB

• Replace Main PCB

 

• Non DMX cables

• Use only DMX compatible cables

 

• Bouncing signals

• Install terminator as suggested.

 

• Long cable / Low level signal

• Install amplifier right after fixture

Loss of signal

with strong signal.

 

• Too many fixtures

• Install an optically coupled DMX

 

 

splitter after unit #32.

 

 

 

• Interference from AC wires

• Keep DMX cables separated from

 

power cables or black lights.

 

 

If you still have a problem after trying the above solutions, please contact CHAUVET®

Technical Support.

5. Appendix

11

11/19/2010 11:07 AM

Image 11
Contents Page Table of Contents Manual Conventions What is includedBefore YOU Begin Unpacking InstructionsSafety Instructions Product Overview IntroductionPower Linking SetupAC Power Mounting Operation Configuring the Starting AddressMaster/Slave Mode Sound-Active, Auto Mode Operating InstructionsAutomatic StandaloneSound-Active CH ModeDMX Channel Values Appendix General TroubleshootingDMX Data Cable DMX PrimerFixture Linking Daisy Chain Data CablingSetting the Starting Address Cable ConnectorsSetting up a DMX Daisy Chain Pin to 5-Pin Conversion ChartClaims General MaintenanceReturns Procedure Power Technical SpecificationsWorld Wide Contact US