Chauvet LX5 user manual General Maintenance, Returns Procedure, Claims

Page 9

General Maintenance

To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance and can cause overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance.

Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust collected on external vents and internal components. Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical surfaces until they are free of haze and lint.

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.

Returns Procedure

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use.

Note:

If you are given an RA #, please include the following information on a piece of paper

 

inside the box:

 

1)

Your name

 

2)

Your address

 

3)

Your phone number

 

4)

The RA #

 

5)

A brief description of the symptoms

Claims

Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim for items such as missing component/part, damage not related to shipping, and concealed damage, must be made within seven (7) days of receiving merchandise.

LX5

9

9/17/2007 12:27 PM

Image 9
Contents LX5Snapshot Table of Contents AC Power What is includedBefore YOU Begin Unpacking InstructionsSafety Instructions Features IntroductionProduct Overview Setup Fuse ReplacementMounting Switch Sound Auto TroubleshootingOperating Instructions Technical Support General TroubleshootingGeneral Maintenance Returns ProcedureClaims Power Technical Specifications

LX5 specifications

The Chauvet LX5 is a versatile lighting fixture designed for a range of professional applications, from concert stages to corporate events. Built to enhance the visual experience, the LX5 combines cutting-edge technology with intuitive user interfaces, making it a favorite among lighting designers and technicians.

At the core of the LX5 is its advanced LED technology. Featuring a bright output, this fixture utilizes high-quality RGBW LEDs that produce vivid colors and deep saturation. The LX5 is capable of generating a broad spectrum of hues, making it ideal for creating dynamic and engaging lighting designs. With an exceptional color mixing ability, it can smoothly transition between colors, which is vital for delivering visually appealing performances.

One of the standout features of the LX5 is its sleek, streamlined design. The low-profile housing allows it to be integrated easily into various setups, ensuring that creative lighting can be achieved without overwhelming the stage or event space. Its lightweight construction also facilitates easy transport and setup, making it ideal for mobile applications.

The LX5 comes equipped with various control options, including DMX, allowing for precise and synchronized lighting effects. This makes it easy to coordinate the LX5 with other lighting fixtures in a comprehensive rig. The fixture also supports standalone operation, featuring built-in programs and automated features that allow users to create captivating light displays without a complex setup.

Durability is another critical characteristic of the LX5. Its robust build quality is designed to withstand the rigors of regular use, ensuring reliability in high-pressure environments. Additionally, the fixture includes a quiet fan and thermal management system, allowing it to operate efficiently, even during extended periods.

In terms of versatility, the LX5 excels with its various mounting options, including floor, truss, and bracket mounts. This flexibility allows lighting professionals to adapt the fixture to different venues and configurations, enhancing the overall lighting design.

Overall, the Chauvet LX5 is a powerful lighting solution that combines advanced LED technology with user-friendly features. Its vibrant color output, robust design, and versatile control options make it a valuable tool for any lighting professional looking to create stunning visual experiences. Whether for a high-energy concert, a dramatic theatrical performance, or a polished corporate function, the LX5 delivers exceptional performance and creativity.