The air intake or exhaust ports

 

 

 

 

 

 

are partially obstructed.

 

 

Remove the obstruction.

 

 

 

 

 

 

Vacuum the air inlet located

 

 

The condenser coils are dirty

 

on the side of the unit

 

 

 

 

 

Move the unit to another

The control panel lights

 

The unit has a minor electrical

 

circuit or unplug the unit and

 

fault

 

plug it in again.

are blinking randomly

 

The unit is plugged into an

 

 

Move the unit to another

 

 

 

 

 

 

 

 

outlet that cannot supply the

 

 

circuit or unplug the unit and

 

 

 

correct electricity to the unit

 

 

plug it in again.

 

 

 

 

 

 

The drain pan has no auto

 

 

 

 

 

shut-off- do not leave the unit

 

 

 

 

 

unattended while draining into

 

 

 

 

 

an external drain pan- the

The unit is leaking

 

The unit is draining into the

 

level of water in this drain pan

 

drain pan

 

must be manually monitored

 

 

 

 

 

The drain stopple and plug are

 

 

Install the stopple and drain

 

 

 

not installed

 

 

plug

 

 

 

The unit is not on a level

 

Make sure the unit is on a

 

 

surface

 

level surface

The heater light is

 

 

 

 

Unplug the unit, wait 30

blinking and the heater

 

 

 

 

seconds, and plug the unit

will not turn on

 

The unit is still set in air

 

back in. Then select the heater

 

 

conditioner mode

 

function

The heater light is

 

 

 

 

Allow the unit to run at least 2

blinking, but the heater is

 

The unit is warming up before

 

minutes and the light will stop

working

 

starting full heat mode

 

blinking

The air conditioner is too

 

The unit is positioned on a

 

 

 

 

hard, uneven floor, and is

 

Move the unit onto a level,

loud.

 

 

 

vibrating.

 

carpeted surface.

 

 

 

The Run LED is blinking

 

 

 

 

 

 

and the air conditioner is

 

The internal water reservoir is

 

 

 

beeping.

 

full.

Drain the water reservoir.

The LED display seems to

 

 

 

 

Turn the unit on with the

show that the air

 

 

 

 

conditioner is on, but it is

 

The "Timer on" feature is

 

power button to deactivate the

not working.

 

activated.

 

"Timer on" feature.

"E1" shows in the LED

 

The evaporator sensor has

 

 

 

display.

 

detected a problem.

 

Contact customer service.

"E2" shows in the LED

 

The room temperature sensor

 

 

 

display.

 

has detected a fault.

 

Contact customer service.

 

20

 

 

 

 

Image 21
Contents Page Table of contents Thank you Energy saving tips Specifications Safety precautionsPage Parts Front viewRear view Accessories Installing the exhaust hose InstallationWindow installation Wall installation permanent mounting Page Control panel LED indicatorsRemote Control Setting up the remote controlButtons Remote control functions Page Regulating airflow direction Manual drainage Drain partsDraining with the drain tray Cleaning the exterior MaintenanceCleaning the condenser coils Prefilter and charcoal filterInstalling the charcoal filter Cleaning the prefilterLong term storage Problem Possible Causes Solutions TroubleshootingPage What is Covered Limited warrantyWhat is not Covered Description of Warranty ServiceObtaining Warranty Service

AP410HS specifications

The EdgeStar AP410HS is a versatile and efficient portable air conditioner designed to provide effective cooling solutions for various spaces. With a cooling capacity of 14,000 BTU, this model is particularly well-suited for spaces up to 525 square feet, making it an excellent choice for home offices, bedrooms, or small living rooms.

One of the standout features of the AP410HS is its dual-hose design. Unlike single-hose models that can create negative pressure and draw in hot air, the dual-hose system efficiently exhausts hot air while simultaneously pulling in fresh air from outside. This results in quicker cooling times and improved energy efficiency. The unit also includes a dehumidification function, capable of removing up to 81 pints of moisture per day, which is invaluable in humid environments.

The EdgeStar AP410HS is equipped with a digital display and remote control, allowing users to easily adjust settings from across the room. The programmable timer offers flexibility, allowing you to set the unit to operate only when necessary, helping to reduce energy consumption. The air conditioner features multiple fan speeds, providing customized airflow based on user preference and environmental conditions.

In terms of installation, the EdgeStar AP410HS is designed for user-friendly setup. It comes with easy-to-follow instructions and all necessary components, including a window kit for venting the hoses. The unit is lightweight and portable, featuring sturdy caster wheels, which allow it to seamlessly move from room to room as needed.

Technologically, the unit operates quietly, avoiding the disruptive noise often associated with traditional air conditioning units. The AP410HS is also designed with an eco-friendly refrigerant, ensuring that it meets environmental guidelines while providing efficient cooling.

Additional characteristics include an air filter that is easily accessible and washable, promoting better indoor air quality. The sleek and modern design of the EdgeStar AP410HS makes it a stylish addition to any decor while maintaining its functionality and effectiveness.

In conclusion, the EdgeStar AP410HS combines powerful cooling capabilities with advanced features, making it an excellent investment for anyone seeking a reliable and efficient portable air conditioning solution.