Oreck USER'S GUIDE warranty Filling Your Canister Vapor Cleaner With Water

Page 6

WARNING: You must always inspect your Pistol Grip prior to each use to ensure both O-Ring seals are present (see figure right). Do not operate if both O-Rings are not present. If you attempt to operate the unit without the O-Rings, there is a risk steam will escape between the Pistol Grip and the attachment that may cause scalding.

Filling Your Canister Vapor Cleaner With Water

Step 1: Before filling the Vapor Cleaner, make sure that the unit is NOT plugged in.

Step 2: Turn Safety/Filler Cap counterclockwise to remove. Note: DO NOT remove the Safety/Filler Cap unless the unit is cool!

Step 3: Using the refill bottle add 1 1/2 quarts of water. Place spout all the way inside unit until water stops. Push to release flow. Do not overfill. Replace Filler Cap by turning clockwise - press down firmly to tighten.

Heating time is approximately 5-8 minutes with cold

water.

Step 4: Plug the unit into a standard 120 volt wall (3-prong) grounded receptacle. The power light will illuminate. Depress On/Off button.

Step 5: Allow approximately 5-8 minutes for vapor unit to reach its working temperature and pressure. When the working temperature has

been

reached, the Green Temperature Ready Light will illumi-

nate and the unit

is ready to operate.

Step 6: Connect desired attachments into the Flexible Vapor Hose.

Note: After you start using vapor, the Green Temperature Ready Light will turn on and off intermittently, indicating that vapor is being produced. However, vapor can be continuously used.

Step 7: At the start, some water will come out from the nozzle of the attachment. This is unheated water in the hose and is normal.

IMPORTANT: When the Vapor Cleaner has run out of water, the low-water thermostat will switch off the unit. The heater will NOT turn on again until the boiler has cooled or has been refilled with water again.

IMPORTANT: The “On/Off” button only provides power to the Vapor Generator Heater and the “On” / “Ready” lights. The Handle Vapor Switch

is electronic and receives power directly from the wall plug outlet.

WARNING: When refilling the Vapor Cleaner while it is still hot, the first drops of water might bubble up. Use caution when opening the Safety/Filler Cap. Do not open while hot! Leave the unit plugged in, press the “On/Off” button to “Off”, then depress Handle Switch only to “On” position and leave “On” for 10 minutes to relieve Vapor

5

Image 6
Contents Dristeem Canister Vapor Safety Instructions To reduce the risk of fire, electric shock, or injurySpecial Instructions Accessories DriSteem Canister Vapor Cleaner AssemblyFeatures Optional AccessoriesUsing the Cordwraps Starting Your DriSteem Canister Vapor CleanerAttaching the Shoulder Strap Filling Your Canister Vapor Cleaner With Water Refilling Your Canister Vapor Cleaner With Water Using Your Canister Vapor Cleaner with Floor BrushHow to fit the Towel Over the Rectangular Brush Maximum cleaning powerAccessories to the Flexible Steam Hose Glass and Tile SqueegeeConcentrator Nozzle Carpet Glider with Rectangular Floor/Carpet Brush Small Detail Brushes Brass BrushRectangular Floor/Carpet Brush with Angle Adapter Triangular Corner Brush with Angle AdapterUsing Towels Tips On How To Use Your SystemTemperature WaterUsing Your Canister Vapor Cleaner Wood, Vinyl, and Marble FloorsPage Page Page Rev D R-7747