Weil-McLain 800058000-Brn-PO Rie F5, 800057000-Brn-PO Rie F5 Setting the AIR Adjustment Plate

Page 14

GB

7)Run the burner until the fuel pump has been purged of air, then tighten the bleeder valve and immediately shut down the burner.

8)Reinstall the air tube cover and nozzle line.

9)The burner can now be started normally.

WARNING: Omitting steps 2 and 3 will result in a collection of unburned oil in the combustion chamber creating a haz- ardous situation upon burner startup.

B) TWO LINE (LIFT SYSTEM)

Turn off the main power source to the burner and remove the air tube cover.

Shines a light source on the photocell (now visible where the air tube cover was removed), return power to the burner and activate the burner. With the light source in place, the burner will operate in prepurge only. When the pump is suffi- ciently purged, the hydraulic air shutter will open.

Once the burner is purged, turn off the power source and replace the air tube cover. Return power to the burner. The burner is now ready to operate.

ATTENTION:

It is important that the fuel line be completely sealed and free from air leaks or any internal blockages.

WARNING! WHEN THE BYPASS PLUG IS INSTALLED, A TWO-PIPE SYSTEM MUST BE USED OR FAILURE OF THE PUMP SHAFT WILL OCCUR.

SETTING THE AIR ADJUSTMENT PLATE

The electronic air shutter assembly (1) is operated on a 120V 60Hz. motor, and the burner motor will not operate un- til the air shutter is in its fully open position.

Set the air plate (4) setting according to OEM setup informa- tion or by following the Retrofit settings listed in this manual. To adjust the air plate (4) to the desired set point indicator (2), loosen the center air shutter assembly screw (5) and loosen the side air plate screw (3), move air plate (4) by us- ing the air plate adjust arm. After adjustments are made please retighten screws (3) & (5).

The final position of the air adjustment plate will vary on each installation. Using proper combustion test instruments to establish the proper setting of the air gate setting to achieve safe and efficient results according the appliance information or if not available.

2

3

D7305

1

5

4

NOTE: Variations in flue gas, smoke, CO2 and temperature readings may be experienced when burner cover is put in place. Therefore, the burner cover must be in place when making final combustion instrument readings, to ensure proper test results are obtained.

3223

11

Image 14
Contents Riello Installlation Precautions AIR for CombustionTable of Contents Package Contents List Serial Number IdentificationBurner Components Identification Technical Data SpecificationsBurner Dimensions Burner ComponentsMounting the Burner to the Boiler or Furnace Assembly of AIR Tube to Burner ChassisInitial SET-UP Method 1 Universal Mounting Flange DRY Base BoilerMethod 2 SEMI-FLANGE Collar Method 3 Pedestal MountNo Amulet Amulet Installation InstructionsRequired on some models Key to lay-out AUXApplication Field Wiring MIN. Wire SizeElectrode Setting Nozzle PlacementINSTALLATION/REMOVAL Drawer Assembly Turbulator SettingSingle Line SYSTEM-PIPE Lengths OIL Line ConnectionsSingle Line Gravity Feed System Line Lift SYSTEM-PIPE Lengths Pump PurgeTWO Line Lift System Setting the AIR Adjustment Plate NON-RETROFIT Applications Burner Adjustment TableBurner START-UP Cycle ~ 12sExploded Spare Parts List Spare Parts List Code DescriptionCode Description Burner START- UP Form Burner Start-up Info OILTechnical Support Hotline Riello

800058000-Brn-PO Rie F5, 800059000-Brn-PO Rie F5, 800057000-Brn-PO Rie F5 specifications

Weil-McLain is a well-respected name in the heating industry, known for its commitment to providing high-quality residential and commercial heating solutions. Three models that exemplify this dedication are the Weil-McLain 800057000-Brn-PO Rie F5, 800058000-Brn-PO Rie F5, and 800059000-Brn-PO Rie F5. Each of these models brings unique features, technologies, and characteristics that ensure optimal performance and reliability for users.

The Weil-McLain 800057000-Brn-PO Rie F5 is designed to meet the demands of modern heating systems. This model incorporates advanced materials that enhance durability and efficiency, ensuring lasting performance. A key feature of this unit is its modular design, which facilitates easier installation and maintenance. Its compact size allows for greater flexibility in placement, making it suitable for various residential and commercial environments.

Similarly, the 800058000-Brn-PO Rie F5 focuses on energy efficiency. This model boasts a high AFUE (Annual Fuel Utilization Efficiency) rating, indicating that it converts a significant portion of fuel into heat. This enhances its environmental credentials while also providing cost savings on energy bills. The advanced control systems integrated into this model allow users to customize their heating requirements, making it an excellent choice for those seeking greater control over their indoor climate.

The 800059000-Brn-PO Rie F5 stands out with its robust safety features. It includes multiple safety controls and sensors that monitor system performance, helping to prevent overheating and enhance user safety. This model is also designed for quiet operation, ensuring minimal noise disruption while functioning. Its user-friendly interface simplifies operation, making it accessible for homeowners and professionals alike.

Across all three models, Weil-McLain has utilized cutting-edge technology, including smart thermostats compatibility, to enhance user experience. These units are designed to work seamlessly with modern home automation systems, allowing for remote control and monitoring of heating functions. In summary, the Weil-McLain 800057000, 800058000, and 800059000 models exemplify exceptional engineering, efficiency, and safety, addressing the diverse needs of today’s heating market. With their combination of innovative features and reliable performance, these models stand as a testament to Weil-McLain's expertise and dedication to quality heating solutions.