Weil-McLain C-1013 manual Yes

Page 3

INSUFFICIENT

 

 

Yes

HOT WATER

 

 

 

 

 

 

 

 

 

 

 

EXCESSIVE DOMESTIC

 

 

 

Yes

WATER TEMPERATURE

 

 

 

 

 

 

 

 

 

BOILER RELIEF

 

 

Yes

VALVE LIFTING

 

 

OR WEEPING

 

 

 

 

 

 

TEMPERATURE/

 

 

Yes

PRESSURE RELIEF

 

 

 

VALVE LIFTING

 

 

OR WEEPING

 

 

 

 

 

 

WATER FOUND ON

 

 

Yes

THE FLOOR NEAR

 

 

 

THE TANK

 

 

 

 

 

 

TOP OF TANK/

 

 

Yes

INSULATION WET

 

 

 

 

 

 

 

 

 

WATER QUALITY

 

 

Yes

PROBLEMS

 

 

 

 

 

 

Insufficient Hot Water - page 3

-Undersized water heater

-Boiler system improperly sized

-Check component parts

-Boiler operating temperature

-Location of flow control devices

-Air in system

-Clean boiler system

Excessive Water Temperature - page 6

-Reduce Stacking

-Lowering boiler operating temperature

-Relocating T-stat bulb

-Reverse boiler piping

-Install thermostatic mixing valve

-Recirculation loop

Boiler Relief Valve Lifting or Weeping - page 7

-Undersized boiler expansion tank

-Faulty boiler expansion tank

-Simulate maximum expansion

-Faulty boiler relief valve

-Faulty boiler fill valve

-Inner tank leak

T&P Relief Valve Lifting or Weeping - page 8

-Undersized or missing domestic side expansion tank

-Faulty domestic expansion tank

-Faulty T&P relief valve

-High domestic supply pressure

-Possible water hammering or pressure spikes

-Boiler operating temperature

Water on the Floor - page 9

-From sources other than the water heater

-T&P valve lifting and discharging

-Loose piping connections

Top of Tank / Insulation Wet - page 10

-From sources other than the water heater

-Loose piping connections

-Leakage from the drywell

Water Smells / Taste Bad - page 11

-Water smells like "rotten eggs"

-Milky water

-Rusty discolored water

2

Image 3
Contents 1013 Remember Good Trouble Shooting PracticesYes Action Item Is the boiler system properly sized? Non-WarrantyCheck component parts Clean the boiler system Non-Warranty Check the operating temperature of the boiler Non-WarrantyCheck location of flow control devices Non-Warranty Check for air in the system Non-WarrantyRecirculation Loop Install thermostatic mixing valveCheck for possible ‘inner tank leak’ *reason code Is the expansion tank on the boiler side properly sized?Check the domestic supply pressure entering the water heater Check the operating temperature of the boilerIs the source of water from the T&P relief valve? Is the source of water from the tank?Check all connections boiler connections, air vent… Other causes of smelly water Hot water smells like rotten eggs Non-WarrantyHot water from the faucet appears milky Non-Warranty Discolored water from the hot water faucet Non-Warranty Page Page Page Page Page Page Page Page

C-1013 specifications

The Weil-McLain C-1013 represents a significant advancement in hydronic heating technology, designed for residential and commercial applications. With an array of features that cater to efficient and effective heating, this boiler stands out in the marketplace for its reliability and performance.

One of the main characteristics of the C-1013 is its energy efficiency. Designed to meet stringent efficiency standards, the C-1013 utilizes a variety of innovative technologies to ensure that minimal energy is wasted during operation. This aligns with modern demands for eco-friendly heating solutions, making it a popular choice for those seeking to reduce their carbon footprint.

The boiler is constructed with durable cast iron sections, ensuring long-lasting performance and superior heat retention. Cast iron is known for its excellent thermal conductivity, allowing the C-1013 to provide consistent and uniform heating throughout the space. This robust build contributes to the unit's longevity, as cast iron is less prone to wear and tear compared to other materials.

In terms of heating capacity, the C-1013 is offered in a range of sizes, allowing it to meet a variety of heating demands. Whether for a small home or a larger commercial facility, there is a model that can accommodate specific requirements. Additionally, the boiler is compatible with various heating systems, including radiators and baseboard heaters, offering flexibility in installation.

The C-1013 also features a user-friendly control system, which allows for easy monitoring and adjustments. With digital controls, users can easily manage temperature settings and monitor system performance. Advanced safety features, including high-limit temperature controls and automatic blow-off valves, enhance the boiler's reliability and ensure safe operation.

Furthermore, Weil-McLain emphasizes serviceability in the C-1013 design. The boiler includes access points for easy maintenance and repairs, ensuring that technicians can quickly perform necessary tasks, minimizing downtime and maintaining efficiency.

To summarize, the Weil-McLain C-1013 is a cutting-edge hydronic heating solution, characterized by its energy efficiency, durable cast iron construction, versatile sizing options, and user-friendly controls. With its commitment to reliability and innovation, the C-1013 represents an excellent choice for both residential and commercial heating needs, reflecting Weil-McLain's reputation for quality in the heating industry.