Heath Zenith SL-5411-WH manual Installation, Wall Mount Eave Mount, Black to White to

Page 2

INSTALLATION

For easy installation, select an existing light with a wall switch for replacement.

Route the light control’s wires through the large gasket holes.

Twist the junction box wires and fixture wires together as shown. Secure with wire connectors.

Wall Mount

Eave Mount

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.

For eave mount only:

Swing the sensor head towards the clamp screw

Mounting

Strap

Black to

Black

White to

White

Rubber

Plug

Mounting

Bolt

Gasket

joint.Controls Clamp Screw

Then rotate the sensor head clockwise 180° so the controls face down.

Controls

Controls

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

Wire the Light Control

WARNING: Turn power off at circuit breaker or fuse.

Remove the existing light fixture.

Install the mounting strap as shown using two screws that fit your junction box.

The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.

Junction box ground wire to green ground screw on fixture.

Mount the Light Control

Align the light control cover plate and cover plate gasket. Secure with the mounting bolt.

Push the Rubber Plug firmly into place.

If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant.

To avoid water damage and electrical shock, keep lamp holders 30° below horizontal.

 

Keep lamps at least

 

1" (2.5 cm) from the

Lock Nut

sensor. Do not allow

 

the lamps to block

Lens

the lens.

Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting. When screwing in the floodlamps, do not overtighten.

598-1128-03

Image 2
Contents Model SL-5411 FeaturesOperation RequirementsWall Mount Eave Mount InstallationWire the Light Control Black to White toBottom of Sensor Test and AdjustmentSpecifications Maximum RangeTEN Year Limited Warranty Troubleshooting GuideNo Service Parts Available for this Product Symptom Possible CauseCaracterísticas FuncionamientoModelo SL-5411 RequisitosInstalacion Montaje en pared Montaje en aleroParte de abajo del detector Prueba Y AjusteEspecificaciones Alcance Máximo Angulo de Cobertura MáximaNo hay piezas de servicio disponibles para este producto Guia DE Investigacion DE AveriasServicio Técnico Garantía Limitada a 10 AñosModèle SL-5411 Résumé du mode de commutationFonctionnement CaractéristiquesNoir Montage sousMontage mural Avant-toit Bas du détecteur Essais ET RéglagesFiche Technique Portée maximale Angle deAucune pièce de rechange n’est disponible pour ce produit Service TechniqueGuide DE Dépannage Garantie Limitée DE 10 ANS